Bentley Communities
Bentley Communities
  • Site
  • User
  • Site
  • Search
  • User
  • Welcome
  • Products
  • Support
  • About
  • More
  • Cancel
ProjectWise
  • Product Communities
  • More
ProjectWise
ProjectWise Design Integration Wiki Issue with Bentley Connect Edition and AutoCAD 2014 Civil 3D and Civil 3D 2016 on same PC
    • Sign in
    • +ProjectWise Design Integration Wiki
    • +Bentley i-model Composition Server
    • +Field Data Management - Welcome
    • +ProjectWise Caching Server
    • +ProjectWise Change Storage Area
    • +ProjectWise Integration CONNECT Edition
    • +ProjectWise Design Integration Server
    • +ProjectWise Design Integration V8i
    • +ProjectWise Document Publisher
    • +ProjectWise Edge - Mobile
    • -ProjectWise Explorer Client
      • 55037 Error moving document User cannot delete corrupt files
      • A way to list users and working dirs
      • A way to search documents in a specific version and showing related references (references and referenced by) on search results
      • A way to search only document versions in PW
      • Application Error The instruction at 0x5ad71531 referenced memory at 0x00000014
      • Attribute Exchange tabs grayed out in Excel 2007
      • Attribute not showing in modify command dialog box
      • +Audit Trail - ProjectWise Explorer Client
      • Batch File Renaming in ProjectWise
      • +Bentley IMS Login
      • +BS1192 Rules Engine - ProjectWise Explorer Client
      • Cannot open file class not registered
      • +Check In Dialog - ProjectWise Explorer Client
      • Copy files with document codes
      • Datasources not displaying in ProjectWise Explorer
      • +Document Code - ProjectWise Explorer Client
      • +Document Creation - ProjectWise Explorer Client
      • +Documentation & Help - ProjectWise Explorer Client
      • Drag and Drop Issue in ProjectWise Explorer
      • Error -11149 Cannot save instance to storage
      • Error 112219 "Invalid filename"
      • Error 2627
      • Error 50176 Cannot start application for the specified document. Check your program associations. Operating system function call failed.
      • Error 58057 Creating new version of document in folder
      • Error found in Custom UI XML of "ProjectWise iDesktop Integration"
      • Error on thread and file stuck with coming in status
      • +Export / Import Tool - ProjectWise Explorer Client
      • Failed to get object identifier by its GUID
      • Folder descriptions displaying instead of name?
      • +Folders / Subfolders - ProjectWise Explorer Client
      • +GUI - ProjectWise Explorer Client
      • Inherited Environment
      • +Installation - ProjectWise Explorer Client
      • +Integration - AutoCAD - ProjectWise Explorer Client
      • +Integration - DGN Platform - ProjectWise Explorer Client
      • +Integration - MicroStation - ProjectWise Explorer Client
      • +Integration - Office - ProjectWise Explorer Client
      • +Integration - Revit - ProjectWise Explorer Client
      • Integration with FME
      • Invalid socket The connection to the remote host is broken
      • Issue with Bentley Connect Edition and AutoCAD 2014 Civil 3D and Civil 3D 2016 on same PC
      • Last Error 347 Cannot start application for the specified document
      • Last Error 58174. Error moving document
      • +Localization - ProjectWise Explorer Client
      • Make external clients unable to use licensing
      • +Messaging Service - ProjectWise Explorer Client
      • Microsoft Office 2010 prerequisites are missing
      • +MISC - ProjectWise Explorer Client
      • No scroll bar on the Attribute properties tab
      • +Open / Save / Copy / Move - ProjectWise Explorer Client
      • Opening a file integrated with PW uses the local workspace
      • Optimizing File Transfer Performance in ProjectWise Explorer
      • PDF for Photo Preview are not showing
      • +Photo Preview - ProjectWise Explorer Client
      • Photo-Preview Fix
      • +Project - ProjectWise Explorer Client
      • ProjectWise Explorer Won't Start or is Giving you a "PWC.exe -Application Error
      • Revit - “The file is already open for editing in another process"
      • +Search - ProjectWise Explorer Client
      • +Security and Permissions - ProjectWise Explorer Client
      • Sequence number / serial number is not increasing in document code
      • Setting the default startup folder
      • Spatial Tab missing in ProjectWise Explorer CONNECT for other accounts than main administrator (pwadmin)
      • Troubleshooting ProjectWise Explorer using Process Monitor (ProcMon)
      • +User Tools - ProjectWise Explorer Client
      • Using ScanRefs.exe
      • Using the Local Document Organizer In ProjectWise
      • +Views - ProjectWise Explorer Client
      • Workflow rules engine, Error -50001 Attribute specified in action not found
      • +Workflows & States - ProjectWise Explorer Client
    • +ProjectWise Explorer Client V8i
    • ProjectWise Explorer Connect Edition Upd3 Unattended Install
    • +ProjectWise integration module for Revit
    • +ProjectWise Integration Server
    • +ProjectWise Publishing Server
    • +ProjectWise Solutions
    • +ProjectWise Web View Server
    • ProjectWise Project Insights
    • +ProjectWise Web Cloud Service
    • +ProjectWise Drive
    • +ProjectWise Web View
    • +Microsoft Teams Integration
    • +ProjectWise Workflow Rules Engine
    • +Working from Home with ProjectWise
    • ISO 19650 data model within ProjectWise
    • Learn ProjectWise

     
     Questions about this article, topic, or product? Click here. 

    Issue with Bentley Connect Edition and AutoCAD 2014 Civil 3D and Civil 3D 2016 on same PC

    Steps to reproduce: Install the ProjectWise Connect Edition 10.00.01.28 or 10.00.01.67, and the Add in modules installed by ProjectWise Conn Edition:

    Install the following Add-in Modules:

    ACAD 2014   Addin module 8.11.11.863 (Which covers standard AutoCAd and AutoCAD Civil 3D)

    ACAD 2015 Addin module 8.11.11.863         “                       “                             “

    ACAD 2016 Addin module   8.11.11.863         “                         “                               “

    Revit 2014 Addin module 8.11.11.863           “                       “                           “

         Note: the above modules are all different even though they have the same version number – Must go by “Description” and version number. The errors are brought about by the ACAD 2014 and 2016 Add in modules, in particular, along with having both Civil 3D 2014 and 2016 applications installed.

       Users are getting “Customization File load failed” error messages although many points of ProjectWise Integration with AutoCAD are OK, and no “ProjectWise” on the top ACAD Ribbon.

     


     

     


     

     

     

    It appears there was mixing of the files in C:\Program Data\Bentley\ProjectWise\08.11\AutoCAD\Support\en and C:\Program Data\Bentley\ProjectWise\10.00\AutoCAD\Support\en

     

    The problem is with ProjectWise CUIX files loading into AutoCAD. Issue is with C:\ProgramData\Bentley\ProjectWise folder having the 8.11 folders as well as the 10.00 folders and the files were mixed between these folders in improper form.

     

    Workaround:

     

    To fix this, copy files from C:\ProgramData\Bentley\ProjectWise\ 8.11 to C:\ProgramData\Bentley\ProjectWise \10.00 and vice versa (i.e. making the folders contain the same files, but no .bak files to avoid creating another issue)

    Example of a file to copy idacad19_1menu.cuix representing Acad 2014

      

    Below is a summary of the steps:

     

     - Uninstall all the installed AutoCAD add-ins
     - Manually clean up both ‘C:\ProgramData\Bentley\ProjectWise\08.11\AutoCAD\support\en’ and ‘C:\ProgramData\Bentley\ProjectWise\10.00\AutoCAD\support\en’ folders (remove all the files from these folders)
     - Install the AutoCAD add-ins back (Install the addins from earliest to latest in order)
     - Apply the workaround with copying files in these folders to each other
     - Launch AutoCAD Civil 3D and verify for no error messages.

     

    • civil 3d 2014
    • Share
    • History
    • More
    • Cancel
    • Bill Kenney Created by Bill Kenney
    • When: Mon, Sep 26 2016 10:28 AM
    • Revisions: 1
    • Comments: 0
    Recommended
    Related
    Communities
    • Home
    • Getting Started
    • Community Central
    • Products
    • Support
    • Secure File Upload
    • Feedback
    Support and Services
    • Home
    • Product Support
    • Downloads
    • Subscription Services Portal
    Training and Learning
    • Home
    • About Bentley Institute
    • My Learning History
    • Reference Books
    Social Media
    •    LinkedIn
    •    Facebook
    •    Twitter
    •    YouTube
    •    RSS Feed
    •    Email

    © 2021 Bentley Systems, Incorporated  |  Contact Us  |  Privacy |  Terms of Use  |  Cookies