Bentley Communities
Bentley Communities
  • Site
  • User
  • Site
  • Search
  • User
ProjectWise
  • Product Communities
ProjectWise
ProjectWise Design Integration Wiki Warning message when opening AutoCAD Civil 3D file from ProjectWise
    • Sign In
    • ProjectWise Design Integration Wiki
    • ProjectWise Software Download
    • +ProjectWise Learning
    • +Projectwise Licensing
    • ProjectWise Programming and PowerShell
    • +Projectwise Documentation
    • -ProjectWise Explorer Client
      • +ProjectWise Client
      • +Featured Articles - Projectwise Explorer
      • +Audit Trail - ProjectWise Explorer Client
      • +Bentley IMS Login
      • +BS1192 Rules Engine - ProjectWise Explorer Client
      • +Check In Dialog - ProjectWise Explorer Client
      • +Document Code - ProjectWise Explorer Client
      • +Document Creation - ProjectWise Explorer Client
      • +Documentation & Help - ProjectWise Explorer Client
      • +Environments and Attributes - PWE
      • +Export / Import Tool - ProjectWise Explorer Client
      • +Folders / Subfolders - ProjectWise Explorer Client
      • +GUI - ProjectWise Explorer Client
      • +Installation - ProjectWise Explorer Client
      • +Integration - General
      • +Integration - AutoCAD - ProjectWise Explorer Client
      • -Integration - Civil 3D - ProjectWise Explorer Client
        • Issue with Bentley Connect Edition and AutoCAD 2014 Civil 3D and Civil 3D 2016 on same PC
        • Warning message when opening AutoCAD Civil 3D file from ProjectWise
        • This file 'C3D 2012.CivilDSProj' format is unsupported
      • +Integration - DGN Platform - ProjectWise Explorer Client
      • +Integration - MicroStation - ProjectWise Explorer Client
      • +Integration - Office - ProjectWise Explorer Client
      • +Integration - Revit - ProjectWise Explorer Client
      • +Logs Troubleshooting- ProjectWise Explorer Client
      • +Messaging Service - ProjectWise Explorer Client
      • +MISC - ProjectWise Explorer Client
      • +Open / Save / Copy / Move - ProjectWise Explorer Client
      • +Photo Preview - ProjectWise Explorer Client
      • +ProjectWise Managed Workspaces
      • +Project - ProjectWise Explorer Client
      • +Search - ProjectWise Explorer Client
      • +Security and Permissions - ProjectWise Explorer Client
      • +User Tools - ProjectWise Explorer Client
      • +Views - ProjectWise Explorer Client
      • +Workflows & States - ProjectWise Explorer Client
      • +Network Configuration - Client
    • +ProjectWise Administrator
    • +ProjectWise Integration Server
    • +ProjectWise Caching Server
    • +ProjectWise Gateway Server
    • +ProjectWise User Synchronization Service
    • +ProjectWise Orchestration Framework
    • +ProjectWise Connected Services
    • +Working from Home with ProjectWise
    • +ProjectWise Glossary
    • ProjectWise Hosting - Manage Services
    • +ProjectWise Logging and Tools

     
     Questions about this article, topic, or product? Click here. 

    Warning message when opening AutoCAD Civil 3D file from ProjectWise

    Product(s): ProjectWise Explorer Client V8i
    Version(s): 10.00.02.96
    Environment: N\A
    Area: Integration - Civil 3D
    Subarea: Data Shortcuts

    Problem Description

    When I open an AutoCAD Civil 3D file from ProjectWise I get a ProjectWise Warning message:

    Some Data Shortcut references are failed to change path

    It is recommended to re-open the document to resolve the issue

    To avoid such issues in future, it is recommended to keep Civil 3D project local copies or use #HOOKLESSPATH setting to change the data shortcut reference paths using different method

    Steps to Resolve

    set the following variable:

    Dmssetvar #HOOKLESSREPATH 1

    In ProjectWise Explorer 10.00.02.96 you are seeing this warning message because some of the Data Shortcuts references re-pathing have failed for some of the data shortcuts in DWG master. Meaning that some of the data shortcut references in the master document are pointing to the wrong location on the file system after the document is opened.

    As the message states closing and reopening the Document again should resolve this. On a large project this process can be very time consuming.

    Setting the variable to 1 will open Civil 3D DWG’s faster and will not flag the re-path issue (if document references set is consistent).

    This setting was added to speedup Civil 3D master document open and improve the stability of the data shortcut reference re-path process on open.

    It is possible that any datashortcut that cannot be repathed will not be displayed in the file. You can repair these datashortcuts manually. The next time the file is opened PWE will attempt to fix the datashortcuts again.

    Best practice recommendation when setting the HOOKLESSREPATH variable, is to make routine backups of the drawings. Just as you should have for any production project.

    If you encounter issues after setting the variable please contact Bentley Technical Support

    See Also

      Original Author: Ed Yepes
    • 10.00.02.96
    • ProjectWise
    • Integration - Civil 3D
    • ProjectWise Explorer Client V8i
    • en
    • Data Shortcuts
    • SELECTsupport
    • Share
    • History
    • More
    • Cancel
    • Ed Yepes Created by Ed Yepes
    • When: Wed, Apr 19 2017 4:59 PM
    • Dana Guthrie Last revision by Bentley Colleague Dana Guthrie
    • When: Wed, Oct 19 2022 3:54 PM
    • Revisions: 4
    • Comments: 0
    Recommended
    Related
    Communities
    • Home
    • Getting Started
    • Community Central
    • Products
    • Support
    • Secure File Upload
    • Feedback
    Support and Services
    • Home
    • Product Support
    • Downloads
    • Subscription Services Portal
    Training and Learning
    • Home
    • About Bentley Institute
    • My Learning History
    • Reference Books
    Social Media
    •    LinkedIn
    •    Facebook
    •    Twitter
    •    YouTube
    •    RSS Feed
    •    Email

    © 2023 Bentley Systems, Incorporated  |  Contact Us  |  Privacy |  Terms of Use  |  Cookies