Bentley Communities
Bentley Communities
  • Site
  • User
  • Site
  • Search
  • User
ProjectWise
  • Product Communities
ProjectWise
ProjectWise Design Integration Wiki Last Error [319]. Cannot start application for the specified document
    • Sign In
    • ProjectWise Design Integration Wiki
    • ProjectWise Software Download
    • +ProjectWise Learning
    • +Projectwise Licensing
    • ProjectWise Programming and PowerShell
    • +Projectwise Documentation
    • -ProjectWise Explorer Client
      • +ProjectWise Client
      • +Featured Articles - Projectwise Explorer
      • +Audit Trail - ProjectWise Explorer Client
      • +Bentley IMS Login
      • +BS1192 Rules Engine - ProjectWise Explorer Client
      • +Check In Dialog - ProjectWise Explorer Client
      • +Document Code - ProjectWise Explorer Client
      • +Document Creation - ProjectWise Explorer Client
      • +Documentation & Help - ProjectWise Explorer Client
      • +Environments and Attributes - PWE
      • +Export / Import Tool - ProjectWise Explorer Client
      • +Folders / Subfolders - ProjectWise Explorer Client
      • +GUI - ProjectWise Explorer Client
      • +Installation - ProjectWise Explorer Client
      • +Integration - General
      • +Integration - AutoCAD - ProjectWise Explorer Client
      • +Integration - Civil 3D - ProjectWise Explorer Client
      • +Integration - DGN Platform - ProjectWise Explorer Client
      • +Integration - MicroStation - ProjectWise Explorer Client
      • +Integration - Office - ProjectWise Explorer Client
      • +Integration - Revit - ProjectWise Explorer Client
      • +Logs Troubleshooting- ProjectWise Explorer Client
      • +Messaging Service - ProjectWise Explorer Client
      • -MISC - ProjectWise Explorer Client
        • Datasources not displaying in ProjectWise Explorer
        • Error -11149 Cannot save instance to storage
        • Error 50176 Cannot start application for the specified document. Check your program associations. Operating system function call failed.
        • Failed to get object identifier by its GUID
        • 55037 Error moving document User cannot delete corrupt files
        • Application Error The instruction at 0x5ad71531 referenced memory at 0x00000014
        • Audit Trail not showing all expected information
        • Cannot change attribute value to blank / cannot delete attribute value
        • Check in a file from one machine that was checked out on a different machine
        • Error 58033 Deleting Files
        • Error 58060 Error creating a new folder. Cannot create/delete folders. (Solution 500000090006)
        • Error 58063: Invalid Username and Password Combination
        • Error 58838 Cannot Login to the datasource
        • How do I copy the view columns and a list of files to Excel Spreadsheet?
        • Last Error 11502 copying files into ProjectWise
        • Last Error 56049 Cannot log in to the data source. Database communication Error.
        • Last Error 58030 Unable to create new document version
        • Last Error [319]. Cannot start application for the specified document
        • Managed Workspace config file changes are not sticking
        • Security for Working Directories
        • Show Local Document Organizer on log out or when closing program
        • Single Sign On fails for all datasources on one Integration Server
        • SSO Clients are not silently re-authenticated to the datasource
        • User Management Tool
        • User wants an environment attribute to h... (Solution 500000101742)
        • ProjectWise Explorer Won't Start or is Giving you a "PWC.exe -Application Error
        • Spatial Tab missing in ProjectWise Explorer CONNECT for other accounts than main administrator (pwadmin)
        • Affect of updating Adobe Reader on program associations
        • Can't See Datasources from Integration Server When Running Gateway
        • See special characters in the login dialog box
        • Selecting Properties of a document and getting “Windows error with mfc80u.dll”
        • Slow Security Dialog
        • Unable to set managed workspace on a folder or document in PW
        • Last error 58116 Error creating new document. Required fields has no value
      • +Open / Save / Copy / Move - ProjectWise Explorer Client
      • +Photo Preview - ProjectWise Explorer Client
      • +ProjectWise Managed Workspaces
      • +Project - ProjectWise Explorer Client
      • +Search - ProjectWise Explorer Client
      • +Security and Permissions - ProjectWise Explorer Client
      • +User Tools - ProjectWise Explorer Client
      • +Views - ProjectWise Explorer Client
      • +Workflows & States - ProjectWise Explorer Client
    • +ProjectWise Administrator
    • +ProjectWise Integration Server
    • +ProjectWise Caching Server
    • +ProjectWise Gateway Server
    • +ProjectWise User Synchronization Service
    • +ProjectWise Orchestration Framework
    • +ProjectWise Connected Services
    • +Working from Home with ProjectWise
    • +ProjectWise Glossary
    • ProjectWise Hosting - Manage Services

     
     Questions about this article, topic, or product? Click here. 

    Last Error [319]. Cannot start application for the specified document

      Product(s): ProjectWise Explorer Client
      Version(s): 08.11.11.111
      Area:  MISC
      Original Author: Dana Guthrie, Bentley Technical Support Group

    Error or Warning Message

    Last Error [319]  Cannot start application for the specified document. Check your program associations.  Failed to generate managed workspace configuration file. Dynamic library loading failed.

    Explanation

    User has MIcroSation SS2 and 2004 edition on the system
    The global association seems to pick up the 2004 edition
    User created a user association to open SS2

    When opening file via ProjectWise with MIcroSation 2004 it works fine
    When opening file via ProjectWise with MIcroSation SS2 user gets error
    Last Error [319]  Cannot start application for the specified document. Check your program associations.  Failed to generate managed workspace configuration file. Dynamic library loading failed.

    How to Avoid

    Option 1:

    Found that the ProjectWise global association was set for MS 2004
    On the client had user remove the user association and then recreate it

    Go to tools \ associations \ programs
    Change the "select an association view' to User associations
    Scroll down in the list to MicroStation, expand Microstation, Expand open, then if an association exists, right mouse click on it and choose unassociate. Click Okay

    To create a user association, Right click a dgn file, choose open with, browse, if the correct program shows up in the programs page then choose and click okay, if it does not, click the browse button and navigate to the executable in this case ustation.exe then click open, then okay.  If you will always use this program for dgn's, then check the box for always use this program, then click okay

    Had user open local document organizer and purge the workspace files.

    Go to tools local document organizer, click view then choose 'workspace copies'
    Highlight all the workspace files that appear and then right click and choose purge
    You may need to do this for copies as well.

    Then had user open the file via ProjectWise using his user association with MS SS2 and the workspace reloaded and opened the file with no errors

     Option 2:

    Another problem might be that one of the files associated with the workspace, the master file or its references, may be corrupt.

    To test, Export \ Send to folder the master file.  The Master and References should be exported.  In some cases you may get the error while doing the export that points to the offending file.

    If the export succeeds try opening the file locally to see if it opens properly.

     Option 3:

    The ProjectWise Explorer logs (pwc.log) can help narrow down what files that are part of the workspace that are inaccessible.  Contact support for help turning up and reading logs, if needed.

    See Also

    http://communities.bentley.com/products/projectwise/content_management/f/342986/t/88469.aspx

    • MISC
    • error message
    • ProjectWise Explorer Client
    • SELECTsupport
    • Share
    • History
    • More
    • Cancel
    • Dana Guthrie Created by Bentley Colleague Dana Guthrie
    • When: Tue, Aug 20 2013 11:02 AM
    • Dana Guthrie Last revision by Bentley Colleague Dana Guthrie
    • When: Mon, Sep 26 2022 1:57 PM
    • Revisions: 7
    • Comments: 0
    Recommended
    Related
    Communities
    • Home
    • Getting Started
    • Community Central
    • Products
    • Support
    • Secure File Upload
    • Feedback
    Support and Services
    • Home
    • Product Support
    • Downloads
    • Subscription Services Portal
    Training and Learning
    • Home
    • About Bentley Institute
    • My Learning History
    • Reference Books
    Social Media
    •    LinkedIn
    •    Facebook
    •    Twitter
    •    YouTube
    •    RSS Feed
    •    Email

    © 2023 Bentley Systems, Incorporated  |  Contact Us  |  Privacy |  Terms of Use  |  Cookies