AutoCAD titleblock update DMS attributes fails,(_tbupdatedms Failed to update attribute values)
2009-08-28 14:49:23,542 ERROR [3976] pwise.server - Error 8152 "ODBC ERROR: 22001: [Microsoft][ODBC SQL Server Driver][SQL Server]String or binary data would be truncated." reported at func: dsqlOdbc_execDirect line: 10552009-08-28 14:49:23,542 ERROR [3976] pwise.server - Error 3621 "ODBC ERROR: 01000: [Microsoft][ODBC SQL Server Driver][SQL Server]The statement has been terminated." reported at func: dsqlOdbc_execDirect line: 1055
Data in the title block was longer than the attribute it was bound to in PW attribute exchange.
Product TechNotes and FAQs
Bentley Technical Support KnowledgeBase
Bentley LEARN Server
Bentley's Technical Support Group requests that you please confine any comments you have on this Wiki entry to this " Comments or Corrections?" section. THANK YOU!