This CSB will make the vital connection between DGN and ProjectWise WorkSpace according to units.
Please follow the below steps to achieve this.
1. In ProjectWise Administrator, under WorkSpaces > Managed > WorkSpace right-click over the WorkSpace Level and select New > Configuration Block.
2. In the New Configuration Block Properties, enter the name PSCE_UNITSYSTEM and the description Set WorkSpace according to dgn units. Once complete, click Apply.
The dialog title will change to PSCE_UNITSYSTEM Properties.
Note: In the name section underscore ‘_’ (i.e. PSCE_UNITSYSTEM) is not mandatory, one can use blank space also (i.e. PSCE_UNITSYSTEM).
3. Go to the Configuration tab, click on Plus button, and Add the following variable:
Add Variable to the PSCE_UNITSYSTEM CSB -
Name
_PS_UNITSYSTEM
Description
Default unit system setting
Add Value
Operation Type: '='- Assignment
Value Type: String
Value: Metric
Locked
YES
The final dialog will look like the below image. Once all good, click on the OK button.
Tip: When you are working with an imperial workspace e.g. USA_CANDA_Imperial. Set the variable value to imperial.
In this way, we need to create new WorkSpace level CSB for ProStructures unit system.
Next Step: Create a new "WorkSet/Project" level CSB called PSCE_Dynamic_WorkSetName.