In User Part Center, parts are not showing up after creating new parts.


 Product(s):ProSteel
 Version(s):CONNECT Edition (10.XX.00.XX)
 Area:ProSteel Utilities
 Subarea:User Part Center
 Original Author:Vyanktesh Nama, Bentley Product Advantage Group

Problem Description

Parts are not showing up in the User Part Center dialog after creating new parts. The first part created is showing up normally, but the new ones created don't get shown. The program creates the design files just fine, but they are not showing up to be able to get inserted.

Steps to resolve

Please follow the below steps to load all the parts that are newly created.

1. After creating a new user part, please right click on the folder and select Update Data Records as shown in the below image.

2. Then select the User Part folder and you can see the recently created user parts get listed in the second dialog.

In this way, you can load the user parts that are newly created.