When debugging a model and clearing out warnings, fixing the "Tendon radius less than minimum allowed" warning can be a sizeable effort since multiple iterations of adjusting the tendon profile and recalculating the design are usually required. It would be helpful to have the ability display the controlling tendon radius under Visible Objects > Tendons > Generated/Manual Latitude/Longitude Tendon in order to quickly view the actual values on plan instead of hovering over each entry in the Warnings and Errors pane. See marked up screenshots below for clarification on what this could look like.

Taking it one step further, another helpful feature would be an option for automatically raising/lowering the selected parametric tendon profile polylines or manual tendon profile points to match the minimum tendon radius. Alternatively, the warning could indicate the required change in tendon profile elevation to achieve the minimum tendon radius if possible. I'm not sure how the program is actually calculating the tendon radius, but these are just some ideas on how to streamline the design process.