      Austin Norberg
      Austin Norberg
      I am building an Elements model to analyze and existing structure, specifically a concrete dome. Based on the existing drawings (which are from 1940), there is some intricate reinforcing detailed within the structure. There are reinforcing hoops which…
      • over 1 year ago
      • RAM | STAAD | ADINA
      • RAM | STAAD Forum
    • Can Ram concept be used to design a monolithic Slab-on-Grade (BRAB) Foundation?

      andrew hoffman
      andrew hoffman
      Can Ram concept be used to design a monolithic Slab-on-Grade (BRAB) Foundation? These foundations are widely used in Texas, and the WRI (Wire Reinforcement Institute) has a design aid which I am following, but would like to use Ram Concept and would like…
      • over 5 years ago
      • RAM | STAAD | ADINA
      • RAM | STAAD Forum
    • Does STAAD design for CONCRETE SPECIAL MOMENT FRAME as per ACI 318M-11 ??

      Sanjay Kumar
      Sanjay Kumar
      Hi, 1. Does STAAD take into account the ductile detailing provisions of CHAPTER 21 of ACI 318M-11, while arriving at the reinforcement area and stirrup area ?? 3. If those provisions are available, how does STAAD identify a SMRF or IMRF or OMRF in…
      • Answered
      • over 5 years ago
      • RAM | STAAD | ADINA
      • RAM | STAAD Forum
    • ACI 318 Incorrect Moment Capacity Concrete Beam

      Karl G
      Karl G
      Applies To Product: RAM Concrete First Affected Version: Found in Version: 15.05.00 Fixed in Version: Area: Design Issue #: 719833 Problem Description In some cases…
      • over 6 years ago
      • RAM | STAAD | ADINA
      • RAM | STAAD | ADINA Wiki
    • ACI 318 Transverse Reinforcement Boundary Elements of Special Reinforced Concrete Shear Walls

      Karl G
      Karl G
      Applies To Product: RAM Concrete First Affected Version: Found in Version: 15.05.00 Fixed in Version: Area: Design Issue #: 719403 Problem Description ACI 318-14 Section…
      • over 6 years ago
      • RAM | STAAD | ADINA
      • RAM | STAAD | ADINA Wiki
    • ACI 318 Column Design Incorrect Interaction Surface at Points Below Balanced Strain Condition

      Karl G
      Karl G
      Applies To Product: RAM Concrete First Affected Version: Found in Version: 15.03.00 Fixed in Version: 15.05.00 Area: Design Issue #: 640239 and 624489 Problem Description…
      • over 6 years ago
      • RAM | STAAD | ADINA
      • RAM | STAAD | ADINA Wiki
    • ACI 318 Minimum Reinforcement in Spread Foundation with Top and Bottom Reinforcement

      Seth Guthrie
      Seth Guthrie
      Applies To Product: RAM Foundation First Affected Version: Unknown Found in Version: 14.06.00.00 Released in Version: 15.05.00.41 Area: Design Issue #: 617970 Problem…
      • over 6 years ago
      • RAM | STAAD | ADINA
      • RAM | STAAD | ADINA Wiki
    • ACI 318 Shear Design Multi-Story Concrete Columns Seismic Design

      Seth Guthrie
      Seth Guthrie
      Applies To Product: RAM Concrete First Affected Version: Found in Version: 14.06.02.00 Fixed in Version: Area: Design Issue #: 123374 Problem Description The program…
      • over 6 years ago
      • RAM | STAAD | ADINA
      • RAM | STAAD | ADINA Wiki
    • ACI 318 Effective Depth Coupling Beam Design

      Seth Guthrie
      Seth Guthrie
      Product(s): RAM Concrete Shear Wall First Affected Version: Found in Version: 15.00.00.00 Fixed in Version 15.04.00.00 Environment: N/A Area: Design Subarea: N/A Defect…
      • over 3 years ago
      • RAM | STAAD | ADINA
      • RAM | STAAD | ADINA Wiki
    • ACI 318 Column Slenderness Second-Order Effects Along Member Length

      Karl G
      Karl G
      Product(s): RAM Concrete Column First Affected Version: Found in Version: 14.07.01.00 Fixed and Released in Version: 15.09.00.13 Environment: N/A Area: Design Subarea: N/A …
      • over 5 years ago
      • RAM | STAAD | ADINA
      • RAM | STAAD | ADINA Wiki
    • ACI 318 Design of Gravity Beams for Seismic Provisions

      Seth Guthrie
      Seth Guthrie
      Product(s): RAM Concrete Beam First Affected Version: Found in Version: 14.07.01.00 Fixed and Released in Version 15.04.00.00 Environment: N/A Area: Design Subarea: N/A …
      • over 6 years ago
      • RAM | STAAD | ADINA
      • RAM | STAAD | ADINA Wiki
    • ACI 318 Shear Design Gravity Columns for Seismic Provisions

      Seth Guthrie
      Seth Guthrie
      Product(s): RAM Concrete Column First Affected Version: Found in Version: 14.07.01.00 Fixed in Version 15.04.00.00 Environment: N/A Area: Design Subarea: N/A Defect Number…
      • over 6 years ago
      • RAM | STAAD | ADINA
      • RAM | STAAD | ADINA Wiki
    • ACI 318 Column Shear Capacity

      Seth Guthrie
      Seth Guthrie
      Product(s): RAM Concrete Column First Affected Version: Found in Version: 14.07.01.01 Fixed and Released in Version 15.04.00.00 Environment: N/A Area: Design Subarea: N/A …
      • over 6 years ago
      • RAM | STAAD | ADINA
      • RAM | STAAD | ADINA Wiki
    • RE: Ram Elements concrete wall slenderness

      Karl G
      Karl G
      Regretfully, wall slenderness is not included in the concrete wall module. As you have noted, the tilt-up wall module is intended for slender wall design. More on this topic can be found on the web page below: http://communities.bentley.com/products…
      • over 7 years ago
      • RAM | STAAD | ADINA
      • RAM | STAAD Forum
    • RE: Does RAM Concrete check for ACI 21.13: Members not designated as part of the SFR system

      Karl G
      Karl G
      See Section 4.8.4 in the RAM Concrete Column Manual for the sections of 21.13 that are implemented in the program. Induced moments and shears are not calculated by the program, so the program follows ACI 318-11 21.13.4 and not 21.13.2 or 21.13.3 when…
      • over 7 years ago
      • RAM | STAAD | ADINA
      • RAM | STAAD Forum
    • View related content from anywhere
    • More
    • Cancel
    Communities
    • Home
    • Getting Started
    • Community Central
    • Products
    • Support
    • Secure File Upload
    • Feedback
    Support and Services
    • Home
    • Product Support
    • Downloads
    • Subscription Services Portal
    Training and Learning
    • Home
    • About Bentley Institute
    • My Learning History
    • Reference Books
    Social Media
    •    LinkedIn
    •    Facebook
    •    Twitter
    •    YouTube
    •    RSS Feed
    •    Email

    © 2023 Bentley Systems, Incorporated  |  Contact Us  |  Privacy |  Terms of Use  |  Cookies