      Rahul Brijpuriya
      Rahul Brijpuriya
      WHY STAAD NOT SUPPORT THE MULTI THREAD?CORE FOR DESIGN? AS MANY OF SOFTWARE IN MARKET HAS CAPABILTY OF DOING SAME STAAD TAKING MUCH MORE TIME TO DESIGN , HOW TO REDUCE IT AND FOR INDIAN CODES WHEN STAAD SUPPORT MULTICORE/ THREAD TO DESIGN?ANALYSIS THE…
      • 8 days ago
      • RAM | STAAD | ADINA
      • RAM | STAAD Forum
    • Why IS Code 800-2007 LSD fails Ratio INFINITY, while AISC 360-10 ASD passed Beam with Ratio 0.44? Taper beam

      Arun Chugh
      Arun Chugh
      1) Design check by IS Code 800-2007 LSD fails gives result of Bending Ratio = “INFINITY”, which passes with AISC 360-10 ASD Ratio 0.44! Also IS 800 code output does not give any ratio in both major, minor axis! 2) Is this 12 mm Flange thickness is critical…
      • over 1 year ago
      • RAM | STAAD | ADINA
      • RAM | STAAD Forum
    • Member failing due to Critical Sec. 9.3.2.2

      Manas Gupta
      Manas Gupta
      I Need Help in Resolving Failure of Member. This is a tapered I section, but it is failing under clause 9.3.2.2. of IS800. Can anyone help me to resolve this critical condition ? Flange thickness is 12 mm Other details of section in photo. 5826…
      • over 2 years ago
      • RAM | STAAD | ADINA
      • RAM | STAAD Forum
    • Problem modelling plates on top of beams for elevated steel water tank

      SUJAY H M
      SUJAY H M
      I am trying to model a Elevated steel water tank with bracing for analysis in STAAD.Pro. While modelling the structure I've encountered a problem and would like your help. The problem is: While the beam offset works perfectly for modelling a beam…
      • over 3 years ago
      • RAM | STAAD | ADINA
      • RAM | STAAD Forum
    • RAM SS V15.05 Release Notes

      Allen Adams
      Allen Adams
      RAM Structural System CONNECT Edition Update 5 Release 15.05 Release Notes Release Date: July 19, 2017 This document contains important information regarding changes to the RAM Structural System. It is important that all users are aware of these changes…
      • over 6 years ago
      • RAM | STAAD | ADINA
      • RAM | STAAD | ADINA Wiki
    • RE: Design of single angle as per IS 800 and AISC 360-10 codes in STAAD

      Sye
      Sye
      The AISC 360-10 allows single angles to be designed as per geometric axis only under certain conditions like if the angle has a continuous lateral restraint or the angle is an equal angle, bending only about one of the geometric axis with no compression…
      • over 6 years ago
      • RAM | STAAD | ADINA
      • RAM | STAAD Forum
    • Design calculation for double angles as per the IS800-2007 is incorrect when Iy > Iz

      Sye
      Sye
      Applies To Product: STAAD.Pro First Affected Version: Found in Version: 20.07.11.50 Released in Version: 20.07.11.70 Environment: All Area: Design Subarea: IS 800 2007…
      • over 6 years ago
      • RAM | STAAD | ADINA
      • RAM | STAAD | ADINA Wiki
    • Slenderness calculation for double angles as per the IS800-2007 is incorrect when Iy > Iz

      Sye
      Sye
      Applies To Product: STAAD.Pro First Affected Version: 20.07.11.33 Found in Version: 20.07.11.50 Released in Version: 20.07.11.70 Environment: All Area: Design Subarea…
      • over 6 years ago
      • RAM | STAAD | ADINA
      • RAM | STAAD | ADINA Wiki
    • Deflection check per AISC 360/ IS 800/S16-14 code is reporting last load case in the serviceability envelope as critical

      Sye
      Sye
      Applies To Product: STAAD.Pro First Affected Version: 20.07.10.66 Found in Version: 20.07.11.70 Released in Version: 20.07.11.82 Environment: All Area: Design Subarea…
      • over 6 years ago
      • RAM | STAAD | ADINA
      • RAM | STAAD | ADINA Wiki
    • Deflection check as per AISC 360-05/10, IS 800 2007, S16 09/14 is incorrect

      Sye
      Sye
      Applies To Product: STAAD.Pro First Affected Version: Found in Version: 20.07.11.70 Released in Version: 20.07.11.82 Environment: All Area: Design Subarea: AISC 360…
      • over 6 years ago
      • RAM | STAAD | ADINA
      • RAM | STAAD | ADINA Wiki
    • Incorrect section properties considered for design of Pipe sections as per IS800:2007

      Sye
      Sye
      Applies To Product: STAAD.Pro First Affected Version: Found in Version: 20.07.11.70 Released in Version: 20.07.11.82 Environment: All Area: Design Subarea: IS800 2007…
      • over 6 years ago
      • RAM | STAAD | ADINA
      • RAM | STAAD | ADINA Wiki
    • I sections with slender flanges not being checked for flexure as per IS 800 2007

      Sye
      Sye
      Applies To Product: STAAD.Pro First Affected Version: 20.07.11.70 Found in Version: 20.07.11.70 Released in Version: 20.07.11.82 Environment: All Area: Design Subarea…
      • over 6 years ago
      • RAM | STAAD | ADINA
      • RAM | STAAD | ADINA Wiki
    • EUROPEAN SECTIONS

      theocharis tofis
      theocharis tofis
      Hi there, I'm trying to design connections/base plates using RAM Connection V8i rev5.5. I'm using European Sections and seems that they are not compatible with the software, as I have changed my sections to British and works fine. Is there any solution…
      • over 9 years ago
      • RAM | STAAD | ADINA
      • RAM | STAAD Forum
    • Re: Member Property Specification - STAAD.Pro Version: 20.07.06.23

      Jason Coleman
      Jason Coleman
      STAAD.Pro does not design either GENERAL or PRISMATIC members as these have no defined section type. Different shapes have different local failure states, there is no way to identify a user-defined general or prismatic shape. However, any parametric user…
      • over 12 years ago
      • RAM | STAAD | ADINA
      • RAM | STAAD Forum
    • View related content from anywhere
    • More
    • Cancel
    Communities
    • Home
    • Getting Started
    • Community Central
    • Products
    • Support
    • Secure File Upload
    • Feedback
    Support and Services
    • Home
    • Product Support
    • Downloads
    • Subscription Services Portal
    Training and Learning
    • Home
    • About Bentley Institute
    • My Learning History
    • Reference Books
    Social Media
    •    LinkedIn
    •    Facebook
    •    Twitter
    •    YouTube
    •    RSS Feed
    •    Email

    © 2023 Bentley Systems, Incorporated  |  Contact Us  |  Privacy |  Terms of Use  |  Cookies