• CONNECT EDITION UPDATE 7

    CAN YOU PLEASE EXPLAIN WHAT IS SEISMIC -H AND SEISMIC -V??? IF I M RIGHT H FOR HORIZONTAL AND V FOR VERTICAL. NOW MY 2ND QUESTION IS WHEN WE NEED TO CONSIDER SEISMIC- H AND WHEN WE NEED TO CONSIDER SEISMIC -V CASES????
  • STAAD PRO CE UPDATE 7

    WHAT HAPPENED WITH ANALYSIS DON'T KNOW??? OHT 1000 KL INTZR1.STD
  • REGARDING STAAD PRO CONNECT EDITION

    Why is such kind of loading diagram shown when I apply floor load.
  • Regarding Staad

    in the above four images, 2 images show the two different types of arrangement of the beam and the rest two show the bending moment diagram for both arrangements. My question is as we know the positive moment indicates the support moment and the negative…
  • Staad pro ce

    Why this happen each and everytime when i open the model and make any changes than programme is crashed.
  • STAAD PRO CE

    IN MY MODEL PLATE NO. IS NOT VISIBLE, WHY?? I HAVE USED ALL THE OPTION SHOWING THE PLATE NUMBER KINDLY RESOLVE MY ISSUE.
  • Regarding stadd pro ce update 5

    Hello Everyone, Q1. When i modelled geometry and assign the property and than close the model after closing i again open the model than what i see it will break the property into multiple segment like i assign property one by one on each member don…
  • RCDC Imposed load

    I'm Designing a Two-way solid slab (Slab on beams) from Staad pro to RCDC. What is the Imposed Load of RCDC? Does it mean the self-weight of a slab or Floor Finishing load?
  • Primary and Secondary beams Intersection vs merge

    Hello Everyone Which is better to intersect the primary beam and secondary beam (Figure1), or Merge the primary beam to be one (Figure2)?
  • Design of Solid slab (Conventional slabs)

    Hello Everyone For a while, I was using an Advanced Concrete Design (RCDC) for the design of a solid slab. Today I tried to learn the RAM concept for the slab designs but I saw a design of strips that had never seen before (When I was using RCDC and…
  • Regarding Staad Pro

    Hello Everyone 1.Please check it out attached model why i m getting so much moment in bottom coulmn. 2.If the column height is recudecs than why i m getting maximum moment in column 1078 instead of column no. 1047 and 1088. please reply ASAP. …
  • Regarding Moment in Y direction.

    Hello Everyone I just want to know the analysis i m performing is correct or not becoz some of the column moment in y direction is too large and also reinforcement. here is my model please go through it and tell me is it right or not?. bridge 200…
  • Regarding Staad Pro CE

    Hello Sir, I m unable to understand How structure behave when we perform seismic analysis of the structure.Some of the beam the value of moment is very high.I m going to attached my model in which look at the beam 5727 5730 and 5737. please solve…
  • STAAD PRO CE

    Hello Everyone. I just want to know when we model water tank with top, bottom and conical dome. after analysis we got result in terms of stresses for which we need to provide R/F. Now can you please tell me if Sx*thickness give hope force and it…
  • BUILDING PLANNER

    When i open building planner than is type of warning shows refer attached screenshot and program close automatically. note :- i uninstalled program and again installed but facing same issue .
  • Eq analysis.

    Hello Everyone, Can anyone explain me when we do EQ analysis including 1893 part 4 than why Ah value multiplied by 2.
  • staad pro ce

    Can anybody tell me why its happen with plate element the moment of one or two plate element is exeed. The SS attached below if you see the graph than tha value of moment is very less except 1 or 2 plate element. I m confused for what value should…
  • Staad pro CE

    When i m going to applied hydrostatic pressure on plate element than it will not applied througly. As shown in Attached screenshot. Again you can see. in the above screenshot hydraulic pressure applied than what haapen you can see than how can i work…
  • STAAD PRO CONNECT EDITION

    Whenever i want to apply floor load or any other load like wind load etc in which we need to define x ,y & z ranges. if i am defining y range than it will automatically take x and z range. why its happen i don't know. kindly resolve the issue.
  • Regarding Staad Foundation Advance

    Hello, Kindly provide me solution for design of isolated footing with all check (including sliding and overturning). Whenever i m going to design the warning appear shown below. 15:29:46 [INFO] END OF DESIGN FOR NODE NUMBER 25 15:30:48 [INFO]…
  • Regarding Staad Foundation Advance

    Hello, I just want to know whenever i m going to design isolated footing and want to apply all the checks like one way shear, two way shear, sliding & overturning. But when i m going to see design calculation the calculation for overturning and sliding…
  • Regarding Staad Foundation Advance.

    Hello Everyone, Actually whenever i want to run staad foundation or planwin , warning appear on the screen and programme will automatically terminated. Attached Screenshot here.
  • Regarding Staad Pro Connect Edition.

    Hello Everyone. 1. Can anybody tell me what is the difference between load combination & Repeat load and which one is better for consideration for generating load combination with moving load.(Please explain in detail don't tell to refer any clause…
  • Regarding moving load

    Hello Everyone, can anybody tell me how to make combination of moving load with other loads.
  • Regarded Staad pro connect edition

    Hello Everyone. Can anyone provide the solution don't know what happend with connect version 20.00.00.28 update 3. When i analysis the model in series 6 model is work fine but when i m going to import it connect edition it will breakdown the entire…