    • RAM Concept CONNECT Edition V8 Update 4 Release Notes

      Sabrina Tedeschi
      Sabrina Tedeschi
      Release Date: November 2022 Version: RAM Conce pt CONNECT Edition V8 Update 4 Version Number: 08.04.00.122 Download and Installation Instructions Current and past RAM Conce pt releases can be downloaded from the Bentley Software Downloads page…
      • 21 days ago
      • RAM | STAAD | ADINA
      • RAM | STAAD | ADINA Wiki
    • RAM CONCEPT - AS3600 PT Design Flat Plate Strip Segment setting and Errors.

      Michael Hart
      Michael Hart
      Hello, I have recently come back from UK where I did extensive PT design to EC2/TR43 standards, I was very comfortable with the use of RAM to these codes. For 2-way slabs; Full width strip design and Top/Bottom Concrete Stress limits were very simple…
      • over 1 year ago
      • RAM | STAAD | ADINA
      • RAM | STAAD Forum
    • AS 3600

      ANN KOALA
      ANN KOALA
      Hi everyone, I have a couple of questions that need to be addressed here: 1/ Where is the section in the AS 3600 that dictates which one is blade column and which one is wall? 2/ I asked the question 1/ because in Ram Concept, if we define a vertical…
      • over 5 years ago
      • RAM | STAAD | ADINA
      • RAM | STAAD Forum
    • Ram Concept - AS 3600.2009

      VINH DUONG
      VINH DUONG
      Ram concept - AS 3600.2009 Hi everyone, When I first looked into load combination of AS.3600-2009 for prestressed concrete, the initial service load combo in Standard is 0.9SW + 1.15P, which is different from 0.8SW + 1.15P in Ram Concept manual. …
      • over 5 years ago
      • RAM | STAAD | ADINA
      • RAM | STAAD Forum
    • RE: RAM Concept: Span Detailer Producing more Reinforcement

      Seth Guthrie
      Seth Guthrie
      For AS 3600 2009 your bottom steel is probably controlled by section 8.1.6 or 9.4.3.2. For span detailing of RC and PT Two-Way Slabs - Figure 9.1.3.4 is implemented in support and span regions. Clause (b) says to use 75% of the area required by one of…
      • over 6 years ago
      • RAM | STAAD | ADINA
      • RAM | STAAD Forum
    • RE: RAM Concept - Punching Shear Question

      Seth Guthrie
      Seth Guthrie
      We do use the thinnest part of the failure plane for the punching shear calculations. Below is some feedback from the program development manager regarding why we took this approach: The code provisions are based upon a model introduced by B.V.…
      • over 7 years ago
      • RAM | STAAD | ADINA
      • RAM | STAAD Forum
    • RE: RAM ECR parameters

      Seth Guthrie
      Seth Guthrie
      A colleague who is more familiar with the AS 3600 code offered this help. AS 3600 breaks down total shrinkage into autogenous shrinkage and drying shrinkage, whereas Concept only has a single value for shrinkage that represents the combination. I think…
      • over 7 years ago
      • RAM | STAAD | ADINA
      • RAM | STAAD Forum
    • RE: footing slab on piles modelling using Ram Concept

      Seth Guthrie
      Seth Guthrie
      According to the program manual, for one-way slabs, two-way slabs or beams, the program checks AS 3600-2009 section 8.1.6 and 9.4.3.2. If you turn on "Controlling Criteria" through visible objects in Ram Concept you should be able to see which is controlling…
      • over 7 years ago
      • RAM | STAAD | ADINA
      • RAM | STAAD Forum
    • RE: RAM Concept Compression only wall effect

      Seth Guthrie
      Seth Guthrie
      I ran your file with the CONNECT edition (v6.0). 1. I’m not seeing anything that I would call excessive reinforcement around the innder triangular core, not parallel to the walls, nor perpendicular. Since the slab terminates at the wall centerline…
      • over 7 years ago
      • RAM | STAAD | ADINA
      • RAM | STAAD Forum
    • RE: Ram Concept Reinforcement Clause 8.1.5

      Seth Guthrie
      Seth Guthrie
      Take a look at the program manual, section 60.6.7 Section 8.1.5 Ductility of Beams in Bending for details on how section 8.1.5. is implemented (in AS 3600-2009). It is noted that the challenge here is to simultaneously provide positive moment ductility…
      • over 8 years ago
      • RAM | STAAD | ADINA
      • RAM | STAAD Forum
    • RE: Initial Service Design in RAM Concept

      Seth Guthrie
      Seth Guthrie
      In AS3600-2009, the Initial Service code check for a PT slab is code section 8.1.6.2. In the Concept manual, section "60.6.6 8.1.6.2 Transfer Compressive Stress Limits" we give some details about who this is implemented. Here's a copy of that, I think…
      • over 8 years ago
      • RAM | STAAD | ADINA
      • RAM | STAAD Forum
    • RE: RAM CONCEPT: Shear reo in slabs according to AS3600-2009

      Seth Guthrie
      Seth Guthrie
      You might find the section design plot for "Shear Density" to be informative. In the case os your right middle strip, the shear demand is indeed quite small, but a plot of Strength Design - Shear density indicates ties are required at several stations…
      • over 8 years ago
      • RAM | STAAD | ADINA
      • RAM | STAAD Forum
    • RE: RAM Concept - creep factor according to AS3600

      Seth Guthrie
      Seth Guthrie
      I'm paraphrasing something from the Ram Concept development manager, but this seems to fit your situation: Question: " Could you please confirm what we would be using as the value for Creep Factor in the Calc Options menu input. We design to AS3600…
      • over 8 years ago
      • RAM | STAAD | ADINA
      • RAM | STAAD Forum
    • View related content from anywhere
    • More
    • Cancel
    Communities
    • Home
    • Getting Started
    • Community Central
    • Products
    • Support
    • Secure File Upload
    • Feedback
    Support and Services
    • Home
    • Product Support
    • Downloads
    • Subscription Services Portal
    Training and Learning
    • Home
    • About Bentley Institute
    • My Learning History
    • Reference Books
    Social Media
    •    LinkedIn
    •    Facebook
    •    Twitter
    •    YouTube
    •    RSS Feed
    •    Email

    © 2023 Bentley Systems, Incorporated  |  Contact Us  |  Privacy |  Terms of Use  |  Cookies