• Ram connection using Hb force component instead of Hc as the axial force at the vertical brace connection's beam-to-column interface.

    At the vertical brace connection framing-to-beam-column junction , it appears that the Hb force component (required shear force on the gusset-to-beam connection) is considered as the axial force at the beam-to-column connection interface, rather than…
  • Distribution of Forces in the RAM Frame

    Hi Team, I am analyzing a G+4 Story steel Building using ASCE 7-16 and AISC 360-16, At Level 1, Level2, and Level 3 there is Concrete Filled Metal Deck which i considered as Rigid for analysis. At Roof Level there is Bare Metal Deck Which i considered…
  • RAM Structural System Learning Resources

    RAM Structural System provides a complete solution for analysis, design, drafting, and documentation for steel and concrete buildings, foundations, and individual structural components in compliance with a variety of US and international design building…
  • Knee brace gusset to beam/ column connection eccentricity due to workline not coinciding with weld centre

    We have encountered a problem while performing checks in vertical brace knee brace. The software does not allow us to enter the values of Xleft and Xright, which represent the eccentricity from connection centre to workline. As a result, the calculation…
  • WARNING- Deflection check of member # 11 will not be performed as DFF value not provided.

    I am getting this warning: WARNING- Deflection check of member # 11 will not be performed as DFF value not provided. I am sharing the input command. Please provide your view. STAAD SPACE START JOB INFORMATION ENGINEER DATE 15-May-23 END JOB INFORMATION…
  • RAM Steel Beam - Fatal Error for "Illegal Framing Configuration..."

    In RAM Steel Beam, I get Fatal Error for "Illegal Framing Configuration or Missing Slab Edge Detected for a Wall" related to one of the walls of my elevator enclosure. I have deleted the walls and redrawn them; confirming that their nodes match. I have…
  • Steel Beams to Lateral Concrete Columns

    As shown in the image above, a project we have has steel beams connected to concrete columns. Based on geometry alone there should be a moment applied to the column during design in the Concrete module. Added to this, the red beam on the left has a gravity…
  • Uplift point loads in my model are not being considered by the ram beam design module

    I have a building with screen wall loads on the roof. These loads act as a couple with the main post and the kicker having reactions in opposite directions. When I add these loads to the ram model, ram beam module is only considering the downward gravity…
  • How to use .con file for connection check in RAM Steel Module.

    Applies To Product(s): RAM Structural System Version(s): All Environment: N/A Area: RAM Steel Subarea: Connection Check; Reports; Tables I've created a .con…
  • RAM Steel AISC Verification Question

    In the RAM Steel verification document, I noticed that you're using two different equations for the concrete modulus of elasticity Ec. On page 2, you use the AISC Chapter I equation for stud strength, and on page 5 you use ACI Eqn. 19.2.2.1a for I,effective…
  • RAM Frame - Moderately Ductile Beam Requirements

    I am looking at the requirements of the beam at the second story of the chevron BRBF. Why is RAM Frame checking Beam ductility using the Diagonal Brace requirements of AISC 341-16? The output clearly says it does not check the axial demand in the beam…
  • Not a valid "Column base (CB)" joint

    I am attempting to assign and design gusset plate connections using Ram connection using data from a RSS model. When trying to assign a connection detail to a joint the error The joint composed by node "171" and members "120, 886" is not valid "Column…
  • RAM Structural System - Load Distribution on Lateral Walls

    In RAM SS, how does the program distributes the lateral load (seismic and wind) in a rigid and non-rigid diaphragm? What are the differences in outcome with the different diaphragm types specified? My problem: In the picture below, I am showing a…
  • Sloped Joist

    I am aware that RAM SS designates a joist as SP, when the slope is greater than 1/2" rise per 12" span. My question is, for a 2 1/4":12" slope, when the design is given as SP, say 16K4 SP, is the joist designed as 16K4? Or is there any other design I…
  • Moment Not Transferred To Beam Ends Correctly

    Hello, The moment in my frame does not seem to be correctly transferring to the fixed ends of the steel beams. All of the moment connections are set to a fixity of "XXX" and are lateral members. The ends do have moment values but seem to be way smaller…
  • CIRCULAR BEAMS RELEASES PROBELM FOR STEEL TOWER NEED HELP

    Good day guys! I am currently designing Water Tank Steel Tower and I have a lot of questions about it so I'll just enumerate it. 1. For a circular beam (which from Structure Wizard, composed of segmented beams) should I make releases or not? If yes…
  • Wrong Loading Combination for Beam Optimization

    I am working on a two story steel building and am experiencing issues with the beam optimization. RAM is currently using a loading combination for some beams, displayed below, that is not the maximum loading so the beams are designed too small. Instead…
  • Illegal framing Configuration Detected on Beam

    I am getting Illegal Framing Configuration Detected on the circled beams below. Not sure how to resolve this. Immediately to the right of these beams is two way slab, not sure if that has anything to do with it. I modelled slab edge using "Whole Perimeter…
  • Design of Solid slab (Conventional slabs)

    Hello Everyone For a while, I was using an Advanced Concrete Design (RCDC) for the design of a solid slab. Today I tried to learn the RAM concept for the slab designs but I saw a design of strips that had never seen before (When I was using RCDC and…
  • Can you manually change the Material Properties Used in RAM SBeam for Modulus of Elasticity

    Can i manually change the modulus of elasticity used in Ram steel? The client wants us to use E based on the Euro code but design is based on IBC/AISC codes.
  • Composite Joists in RSS

    Is there any option for specifying composite joists in RSS? The FloorVibe module had the option to use the SJI Composite Joist designations (i.e. ddCJxxx/xxx where dd is depth and xxx are the applicable loads). But I don't see any implementation of that…
  • Negative Dead Load

    Hello, I am working on a model and getting a large dead load at the end of one of my cantilevers. I have two pinned beams connecting into the end of the cantilever - both have bending moments, shear and deflections that match my hand checks. There is…
  • How to model sloping parapet walls in RAM Structural System

    Hello, I have a one-story building with sloping parapets on the exterior walls and flat parapets on an interior portion (see white colored parapets in image below). Currently, my model has the floor and the roof, with the roof having the deck and…