BEAMS ARE NOT LOADING IN RCDC
NAUSHAD KHAN
I Have created a model in staadpro and analyzed it and I also used mesh tool for slab design now after creating mesh the beams are divided into small length ..... no problem till now but when I import this model in RCDC the beams are not loading (i think…
4 months ago
RAM | STAAD | ADINA
RAM | STAAD Forum
Sway Shear Calculation in STAAD
Abhisek M
Applies To Product(s): STAAD.Pro Version(s): ALL Environment: ALL Area: Design Subarea: Concrete Design Is13920 Original Author: Abhisek Mandal, Bentley Technical Support…
6 months ago
RAM | STAAD | ADINA
RAM | STAAD | ADINA Wiki
Include torsion in beam design as per IS456
Modestas
Applies To Product(s): STAAD Advanced Concrete Design Version(s): All Environment: N/A Area: Concrete Design Subarea: IS 456:2000 Original Author: Abhisek Mandal Bentley…
5 months ago
RAM | STAAD | ADINA
RAM | STAAD | ADINA Wiki
Why IS Code 800-2007 LSD fails Ratio INFINITY, while AISC 360-10 ASD passed Beam with Ratio 0.44? Taper beam
Arun Chugh
1) Design check by IS Code 800-2007 LSD fails gives result of Bending Ratio = “INFINITY”, which passes with AISC 360-10 ASD Ratio 0.44! Also IS 800 code output does not give any ratio in both major, minor axis! 2) Is this 12 mm Flange thickness is critical…
over 1 year ago
RAM | STAAD | ADINA
RAM | STAAD Forum
DEPTH OF BEAM SHALL PREFERABLY BE LESS THAN THE 1/4TH OF CLEAR SPAN
Abhisek M
Applies To Product(s): STAAD.Pro Version(s): ALL Environment: ALL Area: Design Subarea: Concrete Design Is13920 Original Author: Abhisek Mandal, Bentley Technical Support…
6 months ago
RAM | STAAD | ADINA
RAM | STAAD | ADINA Wiki
WARNING BEAM CODE RECOMMENDS THAT WIDTH/DEPTH > 0.3
Abhisek M
Applies To Product(s): STAAD.Pro Version(s): ALL Environment: ALL Area: Design Subarea: Concrete Design Is13920 Original Author: Abhisek Mandal, Bentley Technical Support…
6 months ago
RAM | STAAD | ADINA
RAM | STAAD | ADINA Wiki
The analysis of a stepped column is possible or not?
soumyaranjan samartha
PDF Dear communities, Please provide me the solution or method to design & analysis the STEPPED column. For the reference, I have attached the pdf file, please check it & provide me the solution. Thank you.
over 2 years ago
RAM | STAAD | ADINA
RAM | STAAD Forum
Dummy beam
Sulaiman Ade
Hello Everyone. I create a dummy beam with density=0 and E=0 (Figure.1) then I assign the beam (Figure.2) then Staad Error occurs( ***ERROR*** MATERIAL NAME MUST NOT CONTAIN ANY BLANK SPACE )(Figure.3), What is the solution?
Answered
over 2 years ago
RAM | STAAD | ADINA
RAM | STAAD Forum
RC designer beam fail
Subin kumar
Hello , I have done analysis and tried RC designer . the columns are safe. Beam summary show fails. please help me into this . cross section of beam is large i assume. 8284.COLLEGE PROKECT.STD
over 3 years ago