How do select the angle between truss members?
NAUSHAD KHAN
I want create a truss I chose one from structure wizard but I want a specific angle between truss members at end points (usually referred as alpha) where I can change the default settings for this?
Answered
6 months ago
RAM | STAAD | ADINA
RAM | STAAD Forum
STAAD.Pro Progress Bar View ?
Dani Paul
Dear Colleagues, after some time working in STAAD, a new window/application by the name 'ProgressBarView' seems to open; however unable to select/see that (or) trace that in Task Manager; but my daily activity is not affected by that window. snaps…
6 months ago
RAM | STAAD | ADINA
RAM | STAAD Forum
STAAD.pro Structural Tooltip Options
Dani Paul
Dear colleagues, i haven't noticed this before, but recently i had applied more than 3 releases to a member and i noticed that the Structural Tooltip popup (yellow) shows only the first 3 releases and skipped the rest. Structural Tooltip has always…
Answered
6 months ago
RAM | STAAD | ADINA
RAM | STAAD Forum
While doing design program terminates after 165 nos checking,
Karthikeyan T
While doing Concrete deign , Program design command not completed for whols structure, it terminates after 164 or 165th member design, while i check collegue system, it was closed at 200th number, Need suggestion STAAD SPACE CHP UDANKUDI START JOB…
7 months ago
RAM | STAAD | ADINA
RAM | STAAD Forum
Area of Steel Reqd. for Tran. Moment for Load Case ____ exceeds the Maximum Allowable for Element # ______ - STAAD.Pro Connect
Rex Homer C.
Good day. I was analyzing a model and designing the plates I made at STAAD.Pro Advanced Connect Edition 22.00.00.15. After the run analysis, the result gave the above notice on several plate elements I had. I modeled the plate elements using parametric…
7 months ago
RAM | STAAD | ADINA
RAM | STAAD Forum
Analysis file for two different version shows different result
Ankush Kumar
MJB_697+398_P1_R0_I0_300123 - Base pressure (OLD VERSION).std MJB_697+398_P1_R0_I0_300123 - Base pressure.std Please see the base pressure result.
8 months ago
RAM | STAAD | ADINA
RAM | STAAD Forum
Some of the icons in my STAAD.Pro interface are grayed out
Abhisek M
Applies To Product(s): STAAD.Pro Version(s): ALL Environment: ALL Area: General Solutions Subarea: General Information Original Author: Sye Chakraborty, Bentley Technical…
4 months ago
RAM | STAAD | ADINA
RAM | STAAD | ADINA Wiki
Wide Truss Canopy With Cable Questions
ROTCIVMAR NIÑO SANTILLAN
Good Day everyone, I am designing a wide truss canopy with a cable to provide support for deflection. I am having a hard time solving the warnings. Can someone please help me solve the warnings and also teach me on how to analyze cables on STAAD…
11 months ago
RAM | STAAD | ADINA
RAM | STAAD Forum
Supports of soil safe bearing capacity into our grade beam and plinth beam structural designs?
S Thirumarainathan
Respected Engineers, How can we incorporate the additional strength available by soil safe bearing capacity into our grade beam and plinth beam structural designs?
over 1 year ago
RAM | STAAD | ADINA
RAM | STAAD Forum
STAAD.Pro CONNECT Edition Installation
Modestas
Applies To Product(s): STAAD.Pro Version(s): CONNECT Edition Environment: Area: STAAD.Pro Download/Installation/Security/Performance Subarea: Installation Original Author…
6 months ago
RAM | STAAD | ADINA
RAM | STAAD | ADINA Wiki
staad.pro connect edition version 22.10.00.153
S Thirumarainathan
Dear Sir, Our Project Requirement: 600’ x 200’ x 43’ PEB Warehouse We’ve taken a Model of 157’ x 200’ x 43’ for STAAD Analysis as a similitude model with EJ For the last 45 days, our design engineers have been carrying out the design work of the…
over 1 year ago
RAM | STAAD | ADINA
RAM | STAAD Forum
ERROR: MEMBER # 3 IS NOT A VALID COLD-FORMED STEEL SECTION. E-10 - in Staad.pro
S Thirumarainathan
Hi Staad master sirs, I’m Trying with the Staad.pro model of a Rack system with Economic solutions - which consists of Hot Rolled Sections + Cold-Formed Steel sections, by using IS800 + IS801. My entire members are only supposed to be Designed as Hot…
over 1 year ago
RAM | STAAD | ADINA
RAM | STAAD Forum
I am getting error while designing per Chinese Steel Design Code known as SSDD
Modestas
Applies To Product(s): STAAD.Pro Version(s): All Environment: N/A Area: Steel Design Subarea: General Steel Design Solutions Original Author: Global Technical Support…
5 months ago
RAM | STAAD | ADINA
RAM | STAAD | ADINA Wiki
Why IS Code 800-2007 LSD fails Ratio INFINITY, while AISC 360-10 ASD passed Beam with Ratio 0.44? Taper beam
Arun Chugh
1) Design check by IS Code 800-2007 LSD fails gives result of Bending Ratio = “INFINITY”, which passes with AISC 360-10 ASD Ratio 0.44! Also IS 800 code output does not give any ratio in both major, minor axis! 2) Is this 12 mm Flange thickness is critical…
over 1 year ago
RAM | STAAD | ADINA
RAM | STAAD Forum
Hardware requirement
Gary Forrow
Hi, Struggling with response times with running my model at the moment, and need to know what hardware I need to upgrade. I have a Xeon processor E-2176 @ 2.7GHz, 32Gb RAM and have a runtime of nearly 19 minutes A test on an 8th Gen i5-8350U @ 2…
over 1 year ago
RAM | STAAD | ADINA
RAM | STAAD Forum
Purpose of Beam - Graphs Page
Modestas
Applies To Product(s): STAAD.Pro Version(s): All Environment: N/A Area: Postprocessing workflow Subarea: N/A Original Author: Bentley Technical Support Group …
6 months ago
RAM | STAAD | ADINA
RAM | STAAD | ADINA Wiki
STAAD CONNECT - Variance In Length by 0.00001 m
Rakesh Jain
Hey All, While Modelling A Building In Staad Connect Edition, When I Model A Slab Of 5 X 5 m Size In C.E., It Takes The Length As 5.00001 m Irrespective of 5m Length Input, And So It Gives Error While Generating Floor Load With Boundary Of 5 X…
Answered
over 1 year ago
RAM | STAAD | ADINA
RAM | STAAD Forum
Spring Supports: Connect Edition
Superstar123
Hello, I am new to Staad and am unsure how to add spring supports to the top of my structure. I am modeling a simple two column, 1 beam frame with spring supports (absorption pads) that connect the frame to the composite slab above. My question is…
over 1 year ago
RAM | STAAD | ADINA
RAM | STAAD Forum
Section Properties Not displaying in Report In Stadd Connect
Rakesh Jain
Hello Everyone ! I Have Done Analysis For Window Model Using Prismatic General Section. But While Generating Report , No Property Values i.e. Ixx, Iyy, Izz For Prismatic Section Were Displayed in Utilization Ratio Table. Please Suggest How to get…
over 1 year ago
RAM | STAAD | ADINA
RAM | STAAD Forum
Coffee Corner: Updates and Enhancements in STAAD.Pro CONNECT Edition Update 10
Surojit Ghosh
Title: What’s new in STAAD.Pro – Updates and Enhancements in CONNECT Edition Update 10 Presenter: Surojit Ghosh, Senior Structural Engineer, Engineering Simulation, Bentley Systems Date: Wednesday, May 25, 2022 Time: 11:00 AM Gulf Standard Time (GMT…
over 1 year ago
RAM | STAAD | ADINA
RAM | STAAD | ADINA Announcements Forum
Model a curved beam (Displacement)
Francis Nunez
I am modeling a curved roof and used structure wizard to break the curve into smaller segments of a straight line. I can run the model and get the proper reaction and beam results that I previously estimated. The displacement is much greater than I expected…
over 1 year ago
RAM | STAAD | ADINA
RAM | STAAD Forum
Staad.beava in Staad pro connect edition
Sajal Shrivastava
How should I turn on Staad.beava (bridge code) in staad pro connect edition? In the earlier version, it was easily accessible right at the startup menu as per the screenshot attached. Please reply.
Answered
over 1 year ago
RAM | STAAD | ADINA
RAM | STAAD Forum
STAAD.Pro: how to input Lb for AISC 360 steel beam design
Chuen Han Lee
Dear all, I am modelling a simple roof steel frame and the steel beam design is not passing the design check for AIS-360 LRFD LBT I have defined UNT and LY for the steel beam and it should meet the condition of Lp < Lb < Lr, however the design results…
Answered
over 1 year ago
RAM | STAAD | ADINA
RAM | STAAD Forum
Warning for SET STAR 0
Ellen Joy Magat
We been adding SET STAR 0 to use basic solver since there's additional quarterly pay for advance solver. But in the recent update of STAAD. Pro Connect Edition, we find this warning. Is there also any update for the input? .
over 1 year ago
RAM | STAAD | ADINA
RAM | STAAD Forum
Pdf file for STAAD.Pro Help Documentation
Abhisek M
Applies To Product(s): STAAD.Pro Version(s): ALL Environment: ALL Area: General Solutions Subarea: Learning Material Original Author: Sye Chakraborty, Bentley Technical…