In Staad foundation, no design result is getting generated
Dhrubajyoti Ghosh
sabbir ahmed -static - 07.05.22.std SOMEONE PLEASE REPLY, Calculation sheet is not available as design has failed, why it is showing ? sabbir ahmed -static - 07.05.22_foundation.xml
over 1 year ago
RAM | STAAD | ADINA
RAM | STAAD Forum
Design of Solid slab (Conventional slabs)
Sulaiman Ade
Hello Everyone For a while, I was using an Advanced Concrete Design (RCDC) for the design of a solid slab. Today I tried to learn the RAM concept for the slab designs but I saw a design of strips that had never seen before (When I was using RCDC and…
Answered
over 2 years ago
RAM | STAAD | ADINA
RAM | STAAD Forum
Dummy beam
Sulaiman Ade
Hello Everyone. I create a dummy beam with density=0 and E=0 (Figure.1) then I assign the beam (Figure.2) then Staad Error occurs( ***ERROR*** MATERIAL NAME MUST NOT CONTAIN ANY BLANK SPACE )(Figure.3), What is the solution?
Answered
over 2 years ago
RAM | STAAD | ADINA
RAM | STAAD Forum
Design Workflow_Staad Pro and Ram Element
Hazim Al
I start my work flow modeling the structure in Ram Element and apply some of the loads, add the constrains and transfer the structure to Staad Pro for more rigorous analysis and foundation design. Is that an efficient design work flow? Regards.. …
Answered
over 3 years ago
RAM | STAAD | ADINA
RAM | STAAD Forum
UC Ratio problem
arul mani
warehouse.zip wind calculation also in that folder.... try to fix this probem guys
over 4 years ago
RAM | STAAD | ADINA
RAM | STAAD Forum
how to get the loadings details in report????
arul mani
I have got my report, but there is no loading details like dead load, Wind loads and all... In report settings i have added Loadings, but its not showing.... Wt to do???? i want to see other load details. How to get that details?
over 4 years ago
RAM | STAAD | ADINA
RAM | STAAD Forum
UC Ratio problem
arul mani
Actually i need all members UC Ratio values. How to get all values???? Please guys guide me New folder (2).rar
over 4 years ago
RAM | STAAD | ADINA
RAM | STAAD Forum
Design of combined footing with 3 columns using STAAD Foundation Advanced Connect Edition
angkasa consulting
Hi, Is it possible to design a combined footing with 3 columns as shown in the diagram below? I have tried it and find out that STAAD Foundation only allow collinear column to be designed.
over 4 years ago
RAM | STAAD | ADINA
RAM | STAAD Forum
STAAD Foundation Advanced v9.0.0.9 crash
Lucas Mendoza
Hello, I've imported a mat foundation from STAAD.Pro and set up a new mat analysis/design job in SFA. Everything works fine until I analyze the foundation. Each time I hit analyze the program crashes. It successfully analyzes the mat and I get to the…
over 4 years ago
RAM | STAAD | ADINA
RAM | STAAD Forum
STAAD PRO FOUNDATION ADVANCED , TANK FOUNDATION
Selvaraj Selvaraj
Dear Colleagues, After running the analysis for a large irregular mat foundation on STAAD Foundation Advanced Connect Edition 8.4.0.21, it abruptly stops working when trying to load the output after clicking design.
over 4 years ago
RAM | STAAD | ADINA
RAM | STAAD Forum
HOW TO DEAL WITH CONCENTRATED BENDING MOMENTS AROUND COLUMNS IN PLATES ANALYSIS AND DESIGN
Magnus Hwosafe
Hello, Please, I am a bit uncertain about how to interpret or use moment values (plate contours) from staad plate analysis for design. I want to ask, is it correct to design the slab for the concentrated moments that occur around columns and walls…
over 5 years ago
RAM | STAAD | ADINA
RAM | STAAD Forum
Instability of joint with tension cables
Fiona Cheng
Hi Everyone, I am modeling a scaffold to hold wooden banners for an event. Since the scaffold will be standing in an open area and the area of the banner is very large, the builder will use concrete blocks to prevent the structure from being lifted…
Answered