Chetan Mane
I have recently Installed Staad Pro and I am not able to view the report Tab see below snip, How I can turn it on? I am using STAAD.Pro 2023 - Version 23.00.01.25
6 days ago
RAM | STAAD | ADINA
RAM | STAAD Forum
Deflection not appearing in staad output file
Angelo Peredo
I'm having a problem with mu model. How would I make the deflections appear in the staad output file? All I am getting are these I am checking for strength and serviceability check. Load Envelope 1 for Srength and Load Envelope 2 for serviceability…
Answered
2 months ago
RAM | STAAD | ADINA
RAM | STAAD Forum
How to find user connection database folder in Connection Design using STAAD PRO Connect?
Krissada Phattaratanakorn
Is it possible to share the user connection database in Connection Design using STAAD PRO Connect? I'm trying to find a user connection database file location, which I need to share my connection database (created by the user) to the team. My purpose…
Answered
3 months ago
RAM | STAAD | ADINA
RAM | STAAD Forum
Why does STAAD Aluminum Design report fail to give any output in the "Clause" or "L/C" columns in the Utilization Ratio chart.
Brett Eisenhauer
Please help! Designing a simple truss using the Aluminum Code analysis. The initial analysis produced utilization ratios where the "Clause" references AISC's H1-3 Equation and H2-1 Equation. This led to revise my analysis commands so that it was analyzing…
4 months ago
RAM | STAAD | ADINA
RAM | STAAD Forum
STAAD.pro Structural Tooltip Options
Dani Paul
Dear colleagues, i haven't noticed this before, but recently i had applied more than 3 releases to a member and i noticed that the Structural Tooltip popup (yellow) shows only the first 3 releases and skipped the rest. Structural Tooltip has always…
Answered
6 months ago
RAM | STAAD | ADINA
RAM | STAAD Forum
Question regarding StaadPro CE file
Angel Castro
Hello everyone, I am modeling a steel joists truss in Staad pro CE but I am having trouble on how to resolve the warnings and errors. I have a double angle for the top chord and custom section properties for the bottom chord since staad did not have…
8 months ago
RAM | STAAD | ADINA
RAM | STAAD Forum
STAAD Pro Version 22.10.00.153
S Thirumarainathan
WE HAVE TRIED WITH THE FOLLOWING AVAILABLE COLD FORMED SECTIONS: Angle With Lips - 1 Double Angle (LD) Double Angle(SD) Channel With Lips Channel Without Lips Double Channel Back to Back Double Channel Front to Front Zee With Lips …
over 1 year ago
RAM | STAAD | ADINA
RAM | STAAD Forum
Staad Purlin's design was all about failure.
S Thirumarainathan
PEB warehouse structures Please, solve We have been trying to build a PEB staad.pro model of a warehouse for the past several days. We have set up all the IS standards of property and loading settings we know. However, the economic conclusion…
over 1 year ago
RAM | STAAD | ADINA
RAM | STAAD Forum
STAAD Pro "steel design detail" no longer able to show specific selected beam
Desmond You Sheng TONG
I am using STAAD Pro CONNECT Edition v22. After the update, the "Steel Design Detail" in the Report no longer able to select to show specific selected beam. Instead, the report lump every single member design detail in one like below: In previous…
Answered
over 1 year ago
RAM | STAAD | ADINA
RAM | STAAD Forum
STAAD CONNECT - Variance In Length by 0.00001 m
Rakesh Jain
Hey All, While Modelling A Building In Staad Connect Edition, When I Model A Slab Of 5 X 5 m Size In C.E., It Takes The Length As 5.00001 m Irrespective of 5m Length Input, And So It Gives Error While Generating Floor Load With Boundary Of 5 X…
Answered
over 1 year ago
RAM | STAAD | ADINA
RAM | STAAD Forum
After run analysis it always says "temporary local folder specified for analysis does not exist or is not accessible"
Elaiza Joyce Mejia
over 1 year ago
RAM | STAAD | ADINA
RAM | STAAD Forum
THE COMPRESSIVE AXIAL STRESS IN MEMBER # 1049 EXCEEDS 0.08FCK AT SECTION 0.0 MM FOR LOAD # 216 AS PER CL 6.1 OF IS-13920 2016.
Anirudh
Dear All, I got lot of warnings for the beams that the compressive axial stress in member exceed 0.08fck. What is the solution for that i have got lot of warnings regarding this. Please suggest me Thanks & Regards, Anirudh
over 1 year ago
RAM | STAAD | ADINA
RAM | STAAD Forum
STAAAD Physical - Error
Saeid Kanani
Hi Bentley Team, I am in the process of modeling a steel structure with some steel hoppers. Running Integrity Check and Analysis Model show no issue with no error in the model. But when I want to move to Analytical Modeling, the following message…
over 2 years ago
RAM | STAAD | ADINA
RAM | STAAD Forum
Cracked Section for concrete members
Anirudh
Dear All, I have modelled and applied Cracked section properties code specifies Is1893:2016 and in another model i have assigned Global Cracked section properties for the beams and columns. But the results and area of steel in columns and beams are…
over 2 years ago
RAM | STAAD | ADINA
RAM | STAAD Forum
Why RCDC is not Detecting Sherwalls from Etabs .accdb file
Falcon X
When in imported the accdb file in rcdc and select Columns&Walls option after it is showing columns only. not shearwall.
Answered
over 2 years ago
RAM | STAAD | ADINA
RAM | STAAD Forum
how to connect beam to column
Falcon X
how to connect beam to column. column size is 4m x .850m, baem size 0.750m x 0.400m. see the attach file image. Yellow line is the column. .
over 2 years ago
RAM | STAAD | ADINA
RAM | STAAD Forum
how to check clause no 7.6.4 IS 1893 part 1 in staad pro model (clause regarding diaphragm)?
gaurav vijay
May anyone please guide how to apply diaphragm command in line with above mention clause? any special command in Staad-pro to take care of this check.
over 3 years ago
RAM | STAAD | ADINA
RAM | STAAD Forum
STAAD PRO CONNECT - MESHING PLATES
Ignacio Rojas
Hello, How can I change the default settings in both physical and analytical modeling, in order to define the mesh grid size of a plate? 0,3m x 0,3m; 0,2m x 0,2m; etc (e.g.) Thank you. Ignacio
Answered
over 3 years ago
RAM | STAAD | ADINA
RAM | STAAD Forum
Crashing of staad while using beta angle
Shubham Ajaykumar Maurya
Staad crashes while assigning beta angle. Beta angles gets deleted after reopening the staad file.
over 3 years ago
RAM | STAAD | ADINA
RAM | STAAD Forum
Floor slab design
Mukuntheshwaran Venkatesan
I am designing a floor slab for the below mentioned view of the building. In the plan view the center part of the portion is to be left empty and the remaining area should be covered by slabs. In how many ways can i design a slab to account for both the…
Answered
over 4 years ago
RAM | STAAD | ADINA
RAM | STAAD Forum
View related content from anywhere