Bentley Communities
Site
Search
User
Site
Search
User
Product Communities
RAM | STAAD | ADINA
Sign In
All tags
Staad pro connect edition
Bentley Structural
Concrete Design
CONNECT Edition
connection
design
meshing
peb
Physical Modeller
plate
plates
RAM Connection
section wizard
STAAD
STAAD analysis
staad connect edition
Staad pro
staad pro v8i
STAAD.Pro
STAAD.Pro CONNECT Edition
STAAD.Pro V8i
STAADPro
Steel Structure
Structural
Structural Analysis
structural engineering
ERROR - Elastic Modulus not entered for member/element/solid No. - Staad Pro Connect
Superstar123
Hi all, Can someone please help me with this error I am getting? *ERROR** Elastic Modulus Not Enter for Member/Element/Solid No. I ensure my properties and materials are assigned to all members and checked this in the tools section. Yet I still receive…
over 1 year ago
RAM | STAAD | ADINA
RAM | STAAD Forum
Point load on a composite Slab
Superstar123
Hi All, I am trying to model multiple loads along my composite beam. Can I place my loads not on the beam, but between the beams on the slab? I am still very new and not familiar with the software. Thanks!
over 1 year ago
RAM | STAAD | ADINA
RAM | STAAD Forum
Is UNB/UNT/UNL linked to effective length factors Ky and Kz in STAADPRO?
Kay Thi Kyin
Hi all, I was wondering if anyone could provide some clarity on the use of UNL (UNB/UNT) in the case of cantilever members. What I know so far is that Ky and Kz would have some typical factor of 2 or 2.1 for cantilever members, and this impacts the…
over 1 year ago
RAM | STAAD | ADINA
RAM | STAAD Forum
Staad Pro Advanced V22 Update 7 - Creating Load Envelope in Physical Modeler
Arash Nasr
I need to create two load envelopes for strength and deflection checks. I'm using physical modeler for creating the model , therefore the envelope loads can not be created in Analytical model. How could I create envelopes in physical modeler? In general…
Answered
over 1 year ago
RAM | STAAD | ADINA
RAM | STAAD Forum
COLUMN CAP CONNECTION DESIGN
zeeshan haider
Moment at end of beam are 14132 Kip-in ( 1177 Kip-ft) when I design connection they moment considered are 1075.5 Kip-in (89.63 Kip-ft). why moment and forces are taken less then actual in Ram connection. Screenshot are attached.
Answered
over 1 year ago
RAM | STAAD | ADINA
RAM | STAAD Forum
Moment maximum
S A
Analyzer House.std staad BM.pdf
over 1 year ago
RAM | STAAD | ADINA
RAM | STAAD Forum
After run analysis it always says "temporary local folder specified for analysis does not exist or is not accessible"
Elaiza Joyce Mejia
over 1 year ago
RAM | STAAD | ADINA
RAM | STAAD Forum
Support displacement load creating axial member load
Arash Nasr
I created a simple supported beam and apply a support displacement on one end, as attached. The member is free to rotate, however I would expect axial force due to the displacement . The resultant axial force was zero. 2134.Test1.STD
over 1 year ago
RAM | STAAD | ADINA
RAM | STAAD Forum
Deflection check of Built up sections
Nilesh Behede
The deflection check is not performed in STAAD Pro Connect Edition for rolled section with T&B Flange plates. DJ1, DJ2 & DFF are also assigned to the member. Why the deflection check is not performed?
over 1 year ago
RAM | STAAD | ADINA
RAM | STAAD Forum
RCDC V11 BEAM DESIGN FAILED EVEN IN C30, FY 420 AND BIGGER DIMENSION.
Daario furrur
over 1 year ago
RAM | STAAD | ADINA
RAM | STAAD Forum
THE COMPRESSIVE AXIAL STRESS IN MEMBER # 1049 EXCEEDS 0.08FCK AT SECTION 0.0 MM FOR LOAD # 216 AS PER CL 6.1 OF IS-13920 2016.
Anirudh
Dear All, I got lot of warnings for the beams that the compressive axial stress in member exceed 0.08fck. What is the solution for that i have got lot of warnings regarding this. Please suggest me Thanks & Regards, Anirudh
over 1 year ago
RAM | STAAD | ADINA
RAM | STAAD Forum
No member loaded for floor load generation?
Anirudh
Sir I have modelled and applied the loads in the staad interface the loads are applying but after the analysis in the output I'm getting warning that no member is loaded for the floor load generation! I have thoroughly checked the duplicate nodes,orphan…
over 1 year ago
RAM | STAAD | ADINA
RAM | STAAD Forum
Staad Pro - WARNING: The current units are in KN METE. All the design results are in KN MET (unless otherwise noted)
SB
Hello, I keep getting this warning in my analysis output. "WARNING: The current units are in KN METE. All the design results are in KN MET (unless otherwise noted)." Could I request some guidance on how this can be resolved? Thank you
over 2 years ago
RAM | STAAD | ADINA
RAM | STAAD Forum
T BEAM unable to view in RCDC
DHINESHKUMAR RAJAVEL
Hi all, i have two models R1 and R2. In R1 MODEL , I am unable to view T Beam in RCDC software while desinging. in R2 MODEL, I am able to view T beam in RCDC software. both models are almost same only few updations T beam is created using user…
Answered
over 2 years ago
RAM | STAAD | ADINA
RAM | STAAD Forum
STAAAD Physical - Error
Saeid Kanani
Hi Bentley Team, I am in the process of modeling a steel structure with some steel hoppers. Running Integrity Check and Analysis Model show no issue with no error in the model. But when I want to move to Analytical Modeling, the following message…
over 2 years ago
RAM | STAAD | ADINA
RAM | STAAD Forum
Cracked Section for concrete members
Anirudh
Dear All, I have modelled and applied Cracked section properties code specifies Is1893:2016 and in another model i have assigned Global Cracked section properties for the beams and columns. But the results and area of steel in columns and beams are…
over 2 years ago
RAM | STAAD | ADINA
RAM | STAAD Forum
Implemantation of amendment -2 of IS 1893-2016 in staad pro connect edition
Irfan Ahmad
Please let me know that amendment -2 of IS1893-2016 has been updated in the staad pro connect edition. inform the version of that staad pro connect edition if updated otherwise when same will be updated .
over 2 years ago
RAM | STAAD | ADINA
RAM | STAAD Forum
How to apply sequence of loading for elevated water tank resting on sloping ground by using Response spectrum analysis?
Anjali saindane
Hello.sir i m comparative study of elevated water tank resting on sloping ground & take slope varies from 0 to upto 30degree..I have dout in staad model.. actually I already model but my result not getting correct..means as per our study base shear will…
over 2 years ago
RAM | STAAD | ADINA
RAM | STAAD Forum
Staad Reference loads definition for soft storey checking as per indian code is 1893 2016
Anirudh
Hi all the staad reference load is necessary for checking the soft stories. But I have a doubt while defining reference loads the live load has to reduce as per the specified code or we have to assign full live load in the reference loads? Because the…
over 2 years ago
RAM | STAAD | ADINA
RAM | STAAD Forum
Story stiffness calculation in staad?
Anirudh
Hi every one i have modelled staad with same number of columns and all the column sizes are same. so as per the staad literature the stiffness of columns calculated as 12EI/L^3. My member sizes are same and the floor heights are same in staad but the…
over 2 years ago
RAM | STAAD | ADINA
RAM | STAAD Forum
Water Retaining Concrete Sump Design for Leakage Test
Dong Han Lee
Hello, I am using Staad Pro Connect Edition Version 21.03.00.146. I am trying to design water retaining concrete sump for leakage test case using Plate element. There is no Top Slab during the leakage test and fill inside of concrete sump by water…
over 2 years ago
RAM | STAAD | ADINA
RAM | STAAD Forum
Staad Pro Connect Edition - Water Retaining Concrete Sump Design for Leakage Test
Dong Han Lee
Hello, I am using Staad Pro Connect Edition Version 21.03.00.146. I am trying to design water retaining concrete sump for leakage test case using Plate element. There is no Top Slab during the leakage test and fill inside of concrete sump by water…
over 2 years ago
RAM | STAAD | ADINA
RAM | STAAD Forum
**WARNING - COMMAND REQUIRES SECTION FORCES, HOWEVER NO CASES ARE SOLVED YET.
vellean ancheta
could you please help. what would be the problem that I got this warnings FLOOR DIAPHRAGM ************************************************************************************ FLOOR DIAPHRAGM UNIT - KN METE --------------- ---------------- NO.…
over 2 years ago
RAM | STAAD | ADINA
RAM | STAAD Forum
How to create a crusiform type column geometrical properties?
S.Arul Mary
Dear sir, I want to model a slender column with the cruciform cross-section, How to give the geometrical input to staad pro?
over 2 years ago
RAM | STAAD | ADINA
RAM | STAAD Forum
**WARNING: WALL AREA command should be present with ST = 4. Ref Clause 7.6.2b.
T Karariya
GSFG
over 2 years ago
RAM | STAAD | ADINA
RAM | STAAD Forum
View related content from anywhere
More
Cancel
<
>