• STAAD Foundations Punching Shear Dcritical value incorrect

    Hello, I have exported the load cases from a STAAD model to a foundation model, and I have begun the design for pile caps. However, I am getting strange values for Dcritical. I have a 48" thick pile cap, and the effective depth calculation reads as follows…
  • Design of Solid slab (Conventional slabs)

    Hello Everyone For a while, I was using an Advanced Concrete Design (RCDC) for the design of a solid slab. Today I tried to learn the RAM concept for the slab designs but I saw a design of strips that had never seen before (When I was using RCDC and…
  • Dummy beam

    Hello Everyone. I create a dummy beam with density=0 and E=0 (Figure.1) then I assign the beam (Figure.2) then Staad Error occurs( ***ERROR*** MATERIAL NAME MUST NOT CONTAIN ANY BLANK SPACE )(Figure.3), What is the solution?
  • UC Ratio problem

    warehouse.zip wind calculation also in that folder.... try to fix this probem guys
  • PUNCHING SHEAR CALCULATION IS MISSING

    PUNCHING SHEAR CHECK CALCULATION IS NOT GENERATED(MISSING0 WHILE DESINGING IN STAAD FOUNDATION FOR A PARTICULAR STAAD MODEL, INSERTING THE MODEL FOR THE QUIKEST POSSIBLE SOLUTION. KINDLY REVERT AS SOON AS POSSIBLE L-Shaped_combined_Final.sfa
  • how to get the loadings details in report????

    I have got my report, but there is no loading details like dead load, Wind loads and all... In report settings i have added Loadings, but its not showing.... Wt to do???? i want to see other load details. How to get that details?
  • UC Ratio problem

    Actually i need all members UC Ratio values. How to get all values???? Please guys guide me New folder (2).rar