Comparison of Bending Moment of a structure modeled with member and plate entities
Modestas
Applies To Product(s): STAAD.Pro Version(s): ALL Environment: ALL Area: Postprocessing Subarea: Original Author: Bentley Technical Support Group …
4 months ago
RAM | STAAD | ADINA
RAM | STAAD | ADINA Wiki
PROBLAM DURING DESIGN OF BEAM IN ADVANCE CONCRETE DESIGN (RCDC)
Design Can Change The World
When i am going to design beam than rcdc shows this warning and not proceed further for design.
Answered
over 4 years ago
RAM | STAAD | ADINA
RAM | STAAD Forum
Design of Hollow Octagonal Steel Poles. Is it Required to use of Rigid Inplane Rotation Command
AVS_Siddharth
Design of Hollow Octagonal Steel Poles. We have modeled 15 m high vertical steel pole using Finite Plate Elements. The Hollow Steel Pole is connected to Base Plate fixed on a Concrete Pedestal with Four No. of Bolts with Self Weight and Wind Loads applied…
over 8 years ago
RAM | STAAD | ADINA
RAM | STAAD Forum
help needed with concrete design analysis report
Daniel Sanz
Hello everyone, i just need to know if it's possible to print data about the area of reinforcing steel on the reports that can be made by staad.pro, also if there is a way to show those values the same way it does with bending, shear, deflection, envelope…
Answered
over 9 years ago
RAM | STAAD | ADINA
RAM | STAAD Forum
mast tower staad.pro v8i
hock
pl lead me to STAAD PROBLEM EXAMPLE for a mast. Been to a STAAD training & seen an example problem in the handout, but no leads to it. i WOULIKE LIKE TO RUN THAT MODEL & LEARN ITS STRUCTURAL ANALY. & steel DESIGN TO Eurocode checks
over 10 years ago
RAM | STAAD | ADINA
RAM | STAAD Forum
mast tower staad.pro v8i
hock
pl lead me to STAAD PROBLEM EXAMPLE for a mast. Been to a STAAD training & seen an example problem in the handout, but no leads to it. i WOULIKE LIKE TO RUN THAT MODEL & LEARN ITS STRUCTURAL ANALY. & steel DESIGN TO Eurocode checks
over 10 years ago