RAM Frame Exposure - New Building Adjacent to Existing Building
Victoria Flys
I am creating a model of a building that is adjacent to an existing building on 2 sides, and exposed to wind on the other two sides, see snip below. There is an expansion joint between the buildings, so I am modeling the new building as a standalone structure…
3 months ago
RAM | STAAD | ADINA
RAM | STAAD Forum
Note indicating floor diaphragm is to be defined before wind definition
Abhisek M
Applies To Product(s): STAAD.Pro Version(s): ALL Environment: ALL Area: Modeling Solutions Subarea: Loading Original Author: Sye Chakraborty, Bentley Technical Support…
2 months ago
RAM | STAAD | ADINA
RAM | STAAD | ADINA Wiki
Wind Definitions with Multiple Area Loads
Will Zhang
Hi, My company usually only use one wind definition for wins area load and factor it for different wind cases. I have 3 wind definitions, and I am getting these messages in Editor. Is it a warning message? DEFINE WIND LOAD TYPE 1 NESC HEAVY INT…
3 months ago
RAM | STAAD | ADINA
RAM | STAAD Forum
HOW TO FIXED THIS PROBLEM "**WARNING-fx fy fz wind forces: 4.4589E-02 0.0000E+00 0.0000E+00"
Ruel Cepeda
Good day! How to solve this warning? I already set the range of application in the load cases details, still no avail to fix this one. Thanks.
4 months ago
RAM | STAAD | ADINA
RAM | STAAD Forum
Wind Load on Tapered Section -reg.
Dani Paul
Dear Colleagues, current version : STAAD.Pro CONNECT Edition - Version 22.12.00.142 there was a situation where we had to find out the lateral forces due to wind on a light pole (tapered profile) and provide suitable support for the same. Wind was…
6 months ago
RAM | STAAD | ADINA
RAM | STAAD Forum
STAAD Wind Load Generator
rafanan maranea
Regarding wind load generator in STAAD Pro V 22.06.00.138 My structure is simply a box structure but when using wind load generator applied to a group, the wind load generated in +X and -X as well as +Z and -Z have a discrepancy. It seems that loads…
10 months ago
RAM | STAAD | ADINA
RAM | STAAD Forum
Value of Basic Wind Speed generated as per the ASCE code cannot be edited using the GUI
Carlos Aguera
Product: STAAD.Pro First Affected Version: Found in Version: 22.08.00.175 Fixed and Released in Version: Area: Graphic User Interface Issue #: 758059 Problem Description When carrying…
7 months ago
RAM | STAAD | ADINA
RAM | STAAD | ADINA Wiki
STAAD - EUROCODE WIND GENERATOR FOR DUOPITCH ROOF STRUCTURE
Mohammed Othman
Hello Does anyone have a code or a macro to generate wind loads automatically in STAAD using Eurocode 1991-1-4 for a long duopitch roof structure ? I only have the IS875 in the drop down options for 'Wind Load Generator'. I tried to apply the…
over 1 year ago
RAM | STAAD | ADINA
RAM | STAAD Forum
*** ERROR: NOT ALL JOINTS LIE AT THE SAME FLOOR LEVEL.
ROTCIVMAR NIÑO SANTILLAN
Good Morning Everyone, I am analyzing a conveyor support and housing, The structure is located on a pier thats why I added WL & EL. However, there is an error on analyzing the file. Please help me. The nodes are on the same level. Also, please…
Answered
over 1 year ago
RAM | STAAD | ADINA
RAM | STAAD Forum
Code selection for Wind Load generation is grayed out
Abhisek M
Applies To Product(s): STAAD.Pro Version(s): ALL Environment: ALL Area: Modeling Solutions Subarea: Loading Original Author: Sye Chakraborty, Bentley Technical Support…
2 months ago
RAM | STAAD | ADINA
RAM | STAAD | ADINA Wiki
ASCE 7 Generated Wind Loads in STAAD
shaymore
I am trying to check some STAAD models containing ASCE 7 generated wind loads. The details of these wind loadings are proving difficult to verify. If I use STAAD to open the .STD files I was sent, and go into the ASCE 7 wind load dialog box, it appears…
over 1 year ago
RAM | STAAD | ADINA
RAM | STAAD Forum
Modelling Existing Building - Excessive Horizontal Node Displacement where Column meets Truss
Paul Goosney
Hello, I am modelling an existing building, which has a number of columns which connect to the bottom of trusses at approximately midspan. These Columns are at the building face where the wind will act on them. In all load cases where I have generated…
over 2 years ago
RAM | STAAD | ADINA
RAM | STAAD Forum
Why don't we have wind loads incorporated into Staad Pro as per IS Code?
Sidharth Reddy
Even in Staad CE Wind loads are still generated using ASCE code. Also, a number of videos are floating around on youtube explained by people who are not at all subject matter experts.
over 2 years ago
RAM | STAAD | ADINA
RAM | STAAD Forum
Wind Projected Area on Angular Members
Btb
Hi, I am modelling an open structure with angular sections as the vertical members (Telco tower). However I found that the wind forces on the angles are a bit large. So I did a test model to compare a tube 100x100mm and an equal angle 100x100mm, applied…
over 2 years ago
RAM | STAAD | ADINA
RAM | STAAD Forum
Modeling Slopped Roofs and Impacts on Wind Design
Aaron Deaton
Lately I've been running into issues with my lateral analysis on a large, square steel framed building. The roof is an 1-1/2" metal deck that slopes in one direction and drops 10' over the length of the building, which I've modeled as a semirigid diaphragm…
over 2 years ago
RAM | STAAD | ADINA
RAM | STAAD Forum
automatic generation of wind load
atulkumarengineer
. The automatic generation of wind load should be made available to Indian code also apart from American code.It will save lot of time in analysis and manual calculation. REGARDS, ATUL
over 2 years ago
RAM | STAAD | ADINA
STAAD.Pro
Can a metallic sheeting replace the bracings to resist the lateral forces - seismic forces and wind forces, to add stability of the structure?
rsk
I have a slender structure, 5 m x 2.4 m of height 18 m. I wanted to replace the lateral bracings from level 6 m and above with the metallic sheeting, 6mm or more. I have added the plates of thickness 6mm to simulate the sheeting and by adding intermediate…
Answered
over 3 years ago
RAM | STAAD | ADINA
RAM | STAAD Forum
Floor Diaphgram and Moment Release
Anurag Tripathi
0245.struc.STD 1) After applying floor diaphgram i am getting following warning *WARNING- ZERO STIFFNESS IN DIRECTION 2 AT JOINT 32 EQN.NO. 188 ***WARNING - INSTABILITY AT JOINT 980 DIRECTION = MY 2) Have i applied the moment release correctly…
over 3 years ago
RAM | STAAD | ADINA
RAM | STAAD Forum
Negative Load Case vs Negative Load Combination
Dani Paul
Dear Colleagues, Say if I have to apply wind on all the four sides (+x / +z / -x / -z) of an irregular structure/geometry, is it okay to consider only 2 positive cases (+x / +z) as Basic Load Case and generate 4 load combinations with 2 positive and…
Answered
over 3 years ago
RAM | STAAD | ADINA
RAM | STAAD Forum
screenwall at roof level
VAEngr
I have a relatively tall screen wall at the roof level - about 20ft tall - around a mechanical area. The structure is kicked back into the roof diaphragm. What is the best way to model it so that RAM Frame accounts for its wind surface area? The footprint…
over 3 years ago
RAM | STAAD | ADINA
RAM | STAAD Forum
wind load area on whorehouse side bracing
Mujahid Oweida
I have an issue about wind load , when i have (bracing) on the side of whorehouse the area of wind load are dragging to corner of screen and when i delete the (Bracing) the wind are being OK as you see in the pictures it appears that lines are…
Answered
over 3 years ago
RAM | STAAD | ADINA
RAM | STAAD Forum
Distribution of wind loads for building with intermediate floors
JP Connors
I'm using RAM SS to design a building where we have raised slabs modeled due to a bridge framing into the building. I'm wondering if there are any special requirements in order to have RAM use the main floor diaphragms to calculate the tributary heights…
over 4 years ago
RAM | STAAD | ADINA
RAM | STAAD Forum
MSTower Wind Loads
Ibrahim Kadri
Hello everyone, First of all, apologies if this was discussed before but i could not find the answer for this. I have a question about wind load calculations in MSTower software. I just started to use MSTower and try to understand its logic. It is…
over 4 years ago
RAM | STAAD | ADINA
RAM | STAAD Forum
Eurocode with German NA
Nirav Thakkar
Hello, Currently, I am using STAAD pro Connect edition's latest version. Following are question mainly targeting of RCC and Steel structure design in STAAD Pro and in other Bentley tools per Eurocode with German N ational Annex (NA). 1. Can…
over 4 years ago
RAM | STAAD | ADINA
RAM | STAAD Forum
Wind load not applied properly
DHINESHKUMAR RAJAVEL
Hi Engineers, I have modeled a truss structure , in that model wind load is not applied properly../ i have attached model below for reference.../ 01256.std
over 4 years ago
RAM | STAAD | ADINA
RAM | STAAD Forum