Extract beam maximum dead and live loads
Carlos Villegas
Hi, I am trying to export a csv or excel file where I can see the maximum Dead and Live/Roof live load moments in each beam. I need to obtain them unfactored to post-process them in excel. The table would simply have the beam label, Md and ML. I've been…
3 months ago
RAM | STAAD | ADINA
RAM | STAAD Forum
Composite beam with 2 deck types
Carlos Villegas
Hi, I am modelling a beam with a change of deck along the length of the beam (half of the beam has a W2+3.5" verco deck, and the other half has a W2+2" deck). I read this response: Effects of Changing Deck Type - RAM | STAAD | ADINA Wiki - RAM | STAAD…
Answered
4 months ago
RAM | STAAD | ADINA
RAM | STAAD Forum
HI, everyone can anybody help me to create frame for storge oil tank without support (fixed, pinned, foundation,.............etc), because we have crane carry up this frame, so weight of the model will go above cuz crane, need strong designer to solve...
Dragon
STAAD SPACE START JOB INFORMATION ENGINEER DATE 19-Nov-22 END JOB INFORMATION INPUT WIDTH 79 UNIT MMS KN JOINT COORDINATES 12 14700 6850 0; 13 19450 6850 0; 14 27450 6850 0; 15 30101 6850 0; 16 14700 6850 4200; 17 19450 6850 4200; 18 27450 6850 4200;…
10 months ago
RAM | STAAD | ADINA
RAM | STAAD Forum
Design of Solid slab (Conventional slabs)
Sulaiman Ade
Hello Everyone For a while, I was using an Advanced Concrete Design (RCDC) for the design of a solid slab. Today I tried to learn the RAM concept for the slab designs but I saw a design of strips that had never seen before (When I was using RCDC and…
Answered
over 2 years ago
RAM | STAAD | ADINA
RAM | STAAD Forum
Dummy beam
Sulaiman Ade
Hello Everyone. I create a dummy beam with density=0 and E=0 (Figure.1) then I assign the beam (Figure.2) then Staad Error occurs( ***ERROR*** MATERIAL NAME MUST NOT CONTAIN ANY BLANK SPACE )(Figure.3), What is the solution?
Answered
over 2 years ago
RAM | STAAD | ADINA
RAM | STAAD Forum
Yield Strength Rounds Down
Dmitri Babisin
Why does RAM Structural System round down the Yield Strength fy value? I am located in Canada so if I use american steel then I convert the fy=50 000psi to MPa which is approximately 345MPa. So in the Modeler when laying out the beams I type in 345MPa…
Answered
over 3 years ago
RAM | STAAD | ADINA
RAM | STAAD Forum
RAM SS Beam Deflection Error
Timothy Schuster
I just go a more recent version of RAM SS and when I run the beam module there are certain beam that now show that they fail in deflection. But when I look at the report the beam does not fail in deflection. I have tried deleting the beam and putting…
Answered
over 4 years ago
RAM | STAAD | ADINA
RAM | STAAD Forum
how to get the loadings details in report????
arul mani
I have got my report, but there is no loading details like dead load, Wind loads and all... In report settings i have added Loadings, but its not showing.... Wt to do???? i want to see other load details. How to get that details?
over 4 years ago
RAM | STAAD | ADINA
RAM | STAAD Forum
5. RCDC Support Solutions
Abhisek M
Applies To Product(s): STAAD Advanced Concrete Design Version(s): Connect Edition Environment: Area: Concrete Design Subarea: Original Author:…
over 1 year ago
RAM | STAAD | ADINA
RAM | STAAD | ADINA Wiki
ACI 318 Incorrect Moment Capacity Concrete Beam
Karl G
Applies To Product: RAM Concrete First Affected Version: Found in Version: 15.05.00 Fixed in Version: Area: Design Issue #: 719833 Problem Description In some cases…
over 6 years ago
RAM | STAAD | ADINA
RAM | STAAD | ADINA Wiki
ACI 318 Shear Design of SMF Concrete Beams with Two-Way Decks
Karl G
Applies To Product: RAM Concrete First Affected Version: Found in Version: 15.03.00 Fixed in Version: Area: Design Issue #: 641214 Problem Description The design shear…
over 6 years ago
RAM | STAAD | ADINA
RAM | STAAD | ADINA Wiki
ACI 318 Design of Gravity Beams for Seismic Provisions
Seth Guthrie
Product(s): RAM Concrete Beam First Affected Version: Found in Version: 14.07.01.00 Fixed and Released in Version 15.04.00.00 Environment: N/A Area: Design Subarea: N/A …
over 6 years ago
RAM | STAAD | ADINA
RAM | STAAD | ADINA Wiki
RAM Structural System - RAM Concrete
Karl G
The TechNotes and FAQs in this section cover various topics that pertain to RAM Concrete. RAM Concrete Beam [FAQ] RAM Concrete Column - ACI Slenderness Design Concrete Column Minimum Eccentric Moment RAM SS Walls FAQ Wall Boundary Element…
over 7 years ago
RAM | STAAD | ADINA
RAM | STAAD | ADINA Wiki
RAM SS What Beams and Joists Frame Into
Tom Curry
I am trying to use RAM Structural System to design an apartment building out of Steel and Wood. The wood beams are modeled as steel joists (I have custom joist tables set up for the wood beam members). The steel beams are modeled as steel beams. Both…
Answered
over 8 years ago
RAM | STAAD | ADINA
RAM | STAAD Forum
RE: RAM Concrete Beam - Effective Depth used for Deflection Calculations when Reinforcing Continuous at Beam Depth Change
Seth Guthrie
Your images did not come through, but if I understand correctly, you have two consecutive spans that are different depth beams with continuous top bars across the support, but the d value used in the deflection checks is less than expected. Splicing…
over 8 years ago
RAM | STAAD | ADINA
RAM | STAAD Forum
RSS - AISC 6th Edition beams
Tom Shelmerdine
Does anyone have an RSS Beams table with 6th edition beam shapes in it?
over 12 years ago
RAM | STAAD | ADINA
RAM | STAAD Forum
RamContainer MFC Application
afspear
OS: Windows 7 Ram Structural Version: 14.2.2 When viewing in 3D, we selected a concrete beam to view in elevation. A popup error window appeared that said: "RAMContainer MFC Application has stopped working" Re-installing the application fixed…
over 13 years ago
RAM | STAAD | ADINA
RAM | STAAD Forum
Beam "extension" at multi-story column
Jeff VanderMolen
When you model a cantilever beam with type "extension" at a lower level of a multi-story column, does RAM SS analyze the column as continuous or does it assume the beam essentially passes through the column? In other words, do the moments from the cantilever…
over 10 years ago
RAM | STAAD | ADINA
RAM | STAAD Forum
Composite Beam Deflection Query
jpeters85
I am designing a composite floor system as my first project in RAM. As I was looking at the composite beam deflections and checking them to make sure I understood and agreed, it seemed that the Post-Composite Beam Deflections for a S-S beam with a UDL…
over 11 years ago