structural engineering
hello guys can anyone answer me for this point, what's different between specification beam (Release) and normal beam of the structure? the specification beam (release) will remove ?
Dragon
STAAD SPACE START JOB INFORMATION ENGINEER DATE 05-Dec-22 END JOB INFORMATION INPUT WIDTH 79 UNIT METER KN JOINT COORDINATES 1 0 0 0; 2 10 0 0; 3 0 5 0; 4 10 5 0; 5 0 0 10; 6 10 0 10; 7 0 5 10; 8 10 5 10; 9 1.66667 5 0; 10 3.33333 5 0; 11 5 5 0; 12 6…
10 months ago
RAM | STAAD | ADINA
RAM | STAAD Forum
Design of Solid slab (Conventional slabs)
Sulaiman Ade
Hello Everyone For a while, I was using an Advanced Concrete Design (RCDC) for the design of a solid slab. Today I tried to learn the RAM concept for the slab designs but I saw a design of strips that had never seen before (When I was using RCDC and…
Answered
over 2 years ago
RAM | STAAD | ADINA
RAM | STAAD Forum
Dummy beam
Sulaiman Ade
Hello Everyone. I create a dummy beam with density=0 and E=0 (Figure.1) then I assign the beam (Figure.2) then Staad Error occurs( ***ERROR*** MATERIAL NAME MUST NOT CONTAIN ANY BLANK SPACE )(Figure.3), What is the solution?
Answered
over 2 years ago
RAM | STAAD | ADINA
RAM | STAAD Forum
PUNCHING SHEAR CALCULATION IS MISSING
Neethu Prasad
PUNCHING SHEAR CHECK CALCULATION IS NOT GENERATED(MISSING0 WHILE DESINGING IN STAAD FOUNDATION FOR A PARTICULAR STAAD MODEL, INSERTING THE MODEL FOR THE QUIKEST POSSIBLE SOLUTION. KINDLY REVERT AS SOON AS POSSIBLE L-Shaped_combined_Final.sfa
over 4 years ago
RAM | STAAD | ADINA
RAM | STAAD Forum
how to get the loadings details in report????
arul mani
I have got my report, but there is no loading details like dead load, Wind loads and all... In report settings i have added Loadings, but its not showing.... Wt to do???? i want to see other load details. How to get that details?
over 4 years ago
RAM | STAAD | ADINA
RAM | STAAD Forum
no load case associated to the current job is defined as ultimate loading
Haidar Abdul Rohdha
over 5 years ago