• How to combine Moving Load with other existing Loads

    Applies To Product(s): STAAD.Pro Version(s): ALL Environment: ALL Area: Modeling Solutions Subarea: Loading Original Author: Sye Chakraborty, Bentley Technical Support…
  • WARNING-NO MEMBERS IN SPECIFIED VERTICAL RANGE - in STAAD.Pro moving load generation

    Applies To Product(s): STAAD.Pro Version(s): ALL Environment: ALL Area: Modeling Solutions Subarea: Loading Original Author: Sye Chakraborty, Bentley Technical Support…
  • Moving Load Generator- Trailing Vehicle

    Dear sir, I am having a bridge span of 120m and I want to run a moving load as per IRC. While trying, only one vehicle is running from one end to another end. How to create a trailing vehicle with a specific nose to tail spacing option. Is there any…
  • UDL as moving load?

    Is there any direct or indirect option in STAAD pro to apply UDL as moving load?
  • Moving load applied to wrong member

    I am having trouble applying a moving load to a specific member in my model. The model is a temporary bridge support pier. It is a plane frame. The pier consists of three steel columns, steel cross-bracing in one bay, and a steel pier cap. On top of…
  • Live Load Analysis is NOT Running

    Hi, Dear All, Please see the attached model I created. The analysis is not running with some errors which I can not fix. Please help. Thanks, Dong longit model.STD
  • Erroneous Shear in transverse members due to Moving load

    Staad Input: STAAD SPACE START JOB INFORMATION ENGINEER DATE 26-Sep-18 END JOB INFORMATION INPUT WIDTH 79 UNIT METER MTON JOINT COORDINATES 15 -0.9 9 0; 16 -0.9 9 16.61; 28 52.58 9 16.61; 2347 52.58 9 0; 12797 33.86 9 0; 12801 37.86 9 0; 12822 33.86…
  • Moving load with load combinations

    I'm referring to an old response . Would it be technically correct and easier to check which generated load causes the maximum stresses from a crane dedicated model then reflect the corresponding critical load location on the main structure model to be…
  • **WARNING-A MOVING LOAD THAT WOULD HAVE BEEN APPLIED BEYOND THE X AND Z RANGES

    Applies To Product(s): STAAD.Pro Version(s): ALL Environment: ALL Area: Modeling Solutions Subarea: Loading Original Author: Sye Chakraborty, Bentley Technical Support…
  • how to apply moving load using BS code

    Dear Engineers, I have working on Bridge design... Is it possible to apply moving load (HA and HB ) in Bridge deck using BS code... Can any one help me on this issue and tell me how to apply those load plz.../ I am unable to find it...
  • RE: Vehicle Defination

    You can directly define your wheel loads using the option as shown below. All details related to the input are available in section 5.31.1 of the technical reference manual titled Definition of Moving Load System. In addition, for your reference, there…
  • RE: How to apply consider braking load for bridge super structure

    Yes as of now the option using notional load, as outlined in the wiki below, is the only option. http://communities.bentley.com/products/structural/structural_analysis___design/w/structural_analysis_and_design__wiki/25708.how-to-apply-horizontal-moving…
  • RE: Error "Not Enough Space" When adding predefined load to moving load?

    The issue was that you were trying to add a load case to a generation that was not defined ahead of the generation. I moved the load case 146 ahead of the load generation and renumbered it to load case 1. The load generation now works fine with the load…
  • RE: Bridge superstructure load rating

    I have attached a std file with moving load generation using a HS20 truck ( modified the Example 12 ). You can find more details on moving load generation as part of Help > Contents > Application Examples > American Examples > and refer to Example 12…
  • How to view the generated moving loads

    Applies To Product(s): STAAD.Pro Version(s): ALL Environment: ALL Area: Postprocessing Subarea: Original Author: Sye Chakraborty, Bentley Technical Support Group …
  • Re: Moving loads with load combinations

    You should use the ADD LOAD option as explained below for combining other existing load cases with generated moving load cases. If you need to add multiple such cases to the generation, you have to ensure that you define REPEAT LOADs ( and not LOAD COMBINATION…
  • Unable to use the Moving Load functionality

    Applies To Product(s): Microstran Version(s): V8i Environment: N/A Area: Licensing Original Author: Payel Sasmal, Bentley Technical Support Group Problem Description …
  • Moving Loads on Plates

    Applies To Product(s): STAAD.Pro Version(s): ALL Environment: ALL Area: Load Generation Subarea: Moving Load Original Author: Sye Chakraborty, Bentley Technical Support…
  • Distributing the wheel loads to the members of the deck

    Applies To Product(s): STAAD.Pro Version(s): ALL Environment: ALL Area: Modeling Solutions Subarea: Loading Original Author: Kris Sathia, Bentley Technical Support Group…
  • Moving Load on Slab

    Dear All, I want to check a structure due to Dead Load, Live Load and Moving Load. SInce there are load on slab, so I create a dummy beam to cater this issue (let say for brickwall stands on slab). Then the problem is with Moving Load. As we know…