• What triggers a RAM Frame node renumbering?

    Is there a list of conditions under which node numbers in RAM Frame will renumber automatically? I assumed, incorrectly, that node numbers would likely stay intact if grids or columns moved but were not deleted, but that appears not to be the case. It…
  • How to move a node or group of nodes by a certain distance.

    Applies To Product(s): STAAD.Pro Version(s): All Environment: N/A Area: Modeling Solutions Subarea: Geometry Original Author: Phil Riegel, Technical Support Group …
  • Duplicate geometry in Physical modeller Staad Pro

    Hello sirs! Im recently started to learn Staad Pro and i want to know if im going to ignore duplicated nodes while in the Physical Modeller or is there a button or somewhere i can just delete those nodes? When i run the validate check i get the warnings…
  • Rigid diaphragm nodes deleted RAM Elements v16.07.00.248 Release

    Hi, there! Some rigid diaphragm nodes get deleted when run the analysis in RAM Elements v16.07.00.248 release . Is it a bug? 3566.BugReport.zip
  • Can I/How to hide nodes, elements, beams in the GUI in STAAD

    Hello, There are times I want to hide, not delete, certain nodes, elements, members when building a model - I may determine I want to use these again therefore I do not want to delete. I know I can "comment" them out using an asterisk in the STAAD editor…
  • Local Axis of Nodes

    Hello, Benltey! We should've to analyze beam's forces diagram .When we checked the results, we got the value of forces. Then, we checked the results in tab "Report", and found that the values are different. The forces were with the opposite sign.…
  • Staad Global and Local Limiting Displacements

    Hello, I am curious to know if it is possible to set a local node to node displacement limit, whilst allowing the two nodes to displace globally greater than the set limit? The issue I have is that I am modelling in pipe supports which under an applied…
  • RE: How do I merge nodes is RAM Frame model?

    There is no specific tool to merge the nodes. It is usually necessary to move one thing or another so that there is a single point of intersection. This wiki has more tips: RAM Frame Meshing and Segmentation
  • Nodes Not Displayed in Graphics Window

    Applies To Product: Ram Elements First Affected Version: 13.04.00.177 Found in Version: 13.04.01.208 Fixed and Released in Version: 13.05.00.224 Area: Graphics Environment: Win…
  • RAM Frame - Overlapping Node Numbers in Plan View

    Product(s): RAM Structural System; RAM Frame Version(s): Any Environment: N/A Area: Analysis; Graphics Problem Description In plan view within Ram Frame - Analysis mode, showing node numbers (View - Node…
  • Fabric sheeting on top of a structure

    Hi, I'm modeling a structure that consists of a series of concrete columns spreaded on the perimeter of a rectangular shape building, and attached to a channel concrete caps that running on top of perimeter columns, then the channel beam is connected…