• Structural Design as per IS 13920 in staad.

    Hello sir(s), While deigning structure in staad as per IS 13920 i got following Note in output. NOTE :- SOME OF THE BEAMS CONNECTED TO THE COLUMN NO. ** ARE NOT DESIGNED. ONLY SHEAR FORCE FROM ANALYSIS WILL BE CONSIDERED FOR SHEAR DESIGN. Please…
  • Design of Solid slab (Conventional slabs)

    Hello Everyone For a while, I was using an Advanced Concrete Design (RCDC) for the design of a solid slab. Today I tried to learn the RAM concept for the slab designs but I saw a design of strips that had never seen before (When I was using RCDC and…
  • Mton/Cm to Kn/m

    How do I change Mton/Cm to Kn/m
  • i did program for aluminium canopy fixed at roof slab level without support and we are fixing this with heavy duty through bolt anchor of M10, and this alumnium tubes are welded and its supported by 3 brackets (mid & 2 ends),brackets

    dear sir, i didnt know where to fix my fixed support to get the support reactions and wherever i try to fix it shows that shear and moment are zero and also the valuaes of the static results are different from the original support analysed report notes…
  • FLOOR LOAD

    Dear sir, In attached stad file. I am applying the dead load 2kn/m2 as floor load. 1.somewhere I am attaching two secondary beams with primary beams with the same node.is this load distributed all over the area same as 2kn/m2 or where I am having…
  • floor load

    Dear sir, In attached stad file .I am applying the dead load 2kn/m2 as floor load. 1.somewhere i am attaching two secondary beams with primary beams with the same node.is this load distributed all over the area same as 2kn/m2 or where i am having…
  • UC Ratio problem

    warehouse.zip wind calculation also in that folder.... try to fix this probem guys
  • Eurocode with German NA

    Hello, Currently, I am using STAAD pro Connect edition's latest version. Following are question mainly targeting of RCC and Steel structure design in STAAD Pro and in other Bentley tools per Eurocode with German N ational Annex (NA). 1. Can…
  • Shear results from query dialog box and postprocessing are different, so which is correct, please help me

  • how to get the loadings details in report????

    I have got my report, but there is no loading details like dead load, Wind loads and all... In report settings i have added Loadings, but its not showing.... Wt to do???? i want to see other load details. How to get that details?
  • UC Ratio problem

    Actually i need all members UC Ratio values. How to get all values???? Please guys guide me New folder (2).rar
  • How can we incorporate RAM Connection data in ISM file?

    I have a steel structure Modeled, Analysed & Designed in STAAD.Pro V8i SS4 and Connections designed in RAM Connection plugin for STAAD. However, when I'm creating a repository for exporting the data to Pro Steel for detailing, RAM Connection data is not…