Bentley Communities
Bentley Communities
  • Site
  • User
  • Site
  • Search
  • User
RAM | STAAD | ADINA
  • Product Communities
RAM | STAAD | ADINA
RAM | STAAD | ADINA Wiki RAM Frame - Overlapping Node Numbers in Plan View
    • Sign In
    • -RAM | STAAD | ADINA Wiki
      • +ADINA
      • +Integrated Structural Modeling
      • +Structural Analysis Support Solutions
      • +RAM Concept
      • +RAM Connection
      • +RAM Elements
      • +RAM SBeam
      • -RAM Structural System
        • +RAM Structural System - Feature Articles
        • RAM Structural System V17.0 License Consolidation
        • +RAM Structural System Release Notes
        • -RAM Structural System Support Solutions
          • ISM menu is missing under the File Menu
          • +RAM Structural System - General Topics
          • +RAM Structural System - RAM Concrete
          • +RAM Structural System - RAM Foundation
          • -RAM Structural System - RAM Frame
            • ASCE 7, AISC 360, and the Direct Analysis Method in the RAM Structural System
            • ASCE 7, AISC 360, and the Effective Length Method in the RAM Structural System
            • CoreBrace Buckling Restrained Braces
            • Earth Pressure in RAM Structural System
            • Missing Load Cases from Generated RAM Frame Load Combinations
            • Program Crash after Changing Beam Size in View/Update Dialog in RAM Frame - Steel Mode
            • RAM Frame - Additional Lateral Restraint
            • +RAM Frame - Building and Frame Story Shear
            • RAM Frame - Center of Rigidity
            • RAM Frame - Criteria - B1 & B2
            • +RAM Frame - Criteria - Diaphragms
            • RAM Frame - Diaphragm Constraints and Gravity Forces in Shear Walls
            • RAM Frame - DXF
            • RAM Frame - Dynamic Analysis FAQ
            • RAM Frame - Eigenvalue Error [TN]
            • +RAM Frame - Load Cases
            • RAM Frame - Masses
            • RAM Frame - Notional Loads
            • RAM Frame - Overlapping Node Numbers in Plan View
            • RAM Frame - Rigid Diaphragm Constraints and Frame Shear [TN]
            • RAM Frame - Rigid End Zone assumptions
            • RAM Frame - Second Order Effects with BS 5950-1:2000
            • RAM Frame - Seismic Loads [FAQ]
            • +RAM Frame - Steel Standard and Seismic Provisions
            • RAM Frame - Story Drift at Control Points
            • RAM Frame - Tension Only [FAQ]
            • RAM Frame - Wind Loads [FAQ]
            • RAM Frame Analysis Stalls
            • RAM Frame Numbers
            • RAM Frame P-Delta [TN]
            • +RAM Frame Troubleshooting [TN]
            • RAM Frame Wall Groups FAQ
            • RAM Instability In Finite Element Analysis [TN]
            • RAM Meshing and Segmentation [TN]
            • RAMSS Truss Modeling And Design [TN]
            • +Red Status Lights for Lateral Load Cases in RAM Frame
          • +RAM Structural System - RAM Modeler
          • +RAM Structural System - RAM Steel
          • +RAM Structural System Tutorial
          • +What is RAM DataAccess? [TN]
        • +Known Issues in Ram Structural System
        • +Recordings from past RAM webinars
      • +STAAD.Pro
      • +STAAD Foundation Advanced
      • +STAAD Advanced Concrete Design (RCDC)
      • +STAAD.building
      • +STAAD RCDC FE
      • +Scenario Services
      • +STAAD.offshore
      • +Limcon
      • +Microstran
      • +MStower
      • +Structural Dashboard
      • +Structural WorkSuite
    • +RAM | STAAD Learning Resources

     
     Questions about this article, topic, or product? Click here. 

    RAM Frame - Overlapping Node Numbers in Plan View

      Product(s): RAM Structural System; RAM Frame
      Version(s): Any
      Environment:  N/A
      Area:  Analysis; Graphics

    Problem Description

    In plan view within Ram Frame - Analysis mode, showing node numbers (View - Node Numbers) sometimes causes nodes above or below the plan to also show making it hard to read.

    Reason

    In order to show the nodes from a single plan view, the program uses a cut plane above and below that story. When stories are close together this sometimes causes nodes above or below the plane to still show. Sloped levels, levels with hanging columns and levels with partial height vertical braces (aka knee braces) can also cause problems. 

    Steps to Resolve

    In some cases the problem can be resolved by using low resolution (View - Resolution - Low) also called line mode.

    Using a 3D view with limited vertical extents can also work (View - Extents). Rotate the 3D view using Ctrl+Left mouse button [hold and drag] or the arrow keys. If an angle can be found where the node numbers are mostly legible, print that view.

    The other work-around is use the printed Report - Model Data which includes a listing of the node numbers and coordinates at the end.

    See Also

    RAM SS 3D Viewer FAQ 

    • RAM Frame
    • RAM Structural System
    • nodes
    • 3D
    • Support Solutions
    • Share
    • History
    • More
    • Cancel
    • Seth Guthrie Created by Bentley Colleague Seth Guthrie
    • When: Thu, May 8 2014 12:10 PM
    • Seth Guthrie Last revision by Bentley Colleague Seth Guthrie
    • When: Fri, Dec 7 2018 2:17 PM
    • Revisions: 5
    • Comments: 0
    Recommended
    Related
    Communities
    • Home
    • Getting Started
    • Community Central
    • Products
    • Support
    • Secure File Upload
    • Feedback
    Support and Services
    • Home
    • Product Support
    • Downloads
    • Subscription Services Portal
    Training and Learning
    • Home
    • About Bentley Institute
    • My Learning History
    • Reference Books
    Social Media
    •    LinkedIn
    •    Facebook
    •    Twitter
    •    YouTube
    •    RSS Feed
    •    Email

    © 2023 Bentley Systems, Incorporated  |  Contact Us  |  Privacy |  Terms of Use  |  Cookies