Bentley Communities
Bentley Communities
  • Site
  • User
  • Site
  • Search
  • User
RAM | STAAD | ADINA
  • Product Communities
RAM | STAAD | ADINA
RAM | STAAD | ADINA Wiki ERROR FYLD OUTSIDE THE NORMAL RANGE FOR STEEL
    • Sign In
    • -RAM | STAAD | ADINA Wiki
      • +ADINA
      • +iTwin Analytical Synchronizer_
      • +Structural Analysis Support Solutions
      • +RAM Concept
      • +RAM Connection
      • +RAM Elements
      • +RAM SBeam
      • +RAM Structural System
      • -STAAD.Pro
        • +Revision History
        • -STAAD.Pro Support Solutions
          • STAAD.Pro Safety Related Features
          • -Analytical Modeling workflow
            • -STAAD.Pro Analysis Solutions
              • +Advanced Analysis
              • +Buckling Analysis
              • -DIRECT ANALYSIS
                • Analyzing & designing a structure made of steel and concrete
                • Benchmark problems
                • Deflections with Full E and I values
                • DIRECT ANALYSIS AND ITS IMPLENTATION IN STAAD.PRO
                • DIRECT ANALYSIS and MEMBER TENSION
                • DIRECT ANALYSIS with INACTIVE members
                • Does specifying the Notional Load Factor as 0.002 automatically define notional loads ?
                • ERROR FYLD OUTSIDE THE NORMAL RANGE FOR STEEL
                • Example on Direct analysis with steel design as per AISC 360-10 using STAAD.Pro
                • FLEX and Taub
                • How to find the ratio of second order drift/first order drift
                • Is the reduction in stiffness applied when a response spectrum load case is subjected to DIRECT ANALYSIS
                • Iterations in DIRECT ANALYSIS
                • Loads factored by 1.6 for ASD
                • MEMBER TENSION/COMPRESSION with DIRECT ANALYSIS
                • Response spectrum loading in DIRECT ANALYSIS
                • WARNING: FYLD parameter has been deprecated for Direct Analysis
              • +Dynamic Analysis
              • +Eigen Solution
              • +Floor Response Spectrum Analysis
              • +Instability And Zero Stiffness
              • +Miscellaneous Analysis Solutions
              • +PDELTA Analysis
              • +Pushover Analysis
              • +Response Spectrum Analysis
              • +Seismic Analysis
              • +Time History Analysis
            • +STAAD.Pro Design Solutions
            • +STAAD.Pro General Solutions
            • +STAAD.Pro Import/Export Solutions
            • +STAAD.Pro Modeling Solutions
          • +Building Planner workflow
          • +Connection Design workflow
          • +Physical Modeling workflow
          • +Piping workflow
          • +Postprocessing workflow
          • +Steel AutoDrafter workflow
        • +STAAD.Pro OpenSTAAD
        • +(+) Archived Wikis
        • +STAAD.Pro - Known Issues
        • +STAAD.Pro Download/Installation/Performance/Security
        • +STAAD.Pro Licensing Solutions
        • +STAAD.Pro Webinars/Videos/Events
      • +STAAD Foundation Advanced
      • +STAAD Advanced Concrete Design (RCDC)
      • +STAAD.building
      • +STAAD RCDC FE
      • +Scenario Services
      • +STAAD.offshore
      • +Limcon
      • +Microstran
      • +MStower
      • +Structural Dashboard
      • +Structural WorkSuite
    • +RAM | STAAD Learning Resources
    • Simplifications to Bentley's Engineering Simulation Software Licenses

     
     Questions about this article, topic, or product? Click here. 

    ERROR FYLD OUTSIDE THE NORMAL RANGE FOR STEEL

    Applies To
    Product(s): STAAD.Pro
    Version(s): ALL
    Environment: ALL
    Area: Analysis Solutions
    Subarea: Direct Analysis
    Original Author: Sye Chakraborty, Bentley Technical Support Group

    When I run a DIRECT analysis, I get the following warning

    **ERROR- FYLD OUTSIDE THE NORMAL RANGE FOR STEEL, CHECK UNITS. What does that mean?

     

    As part of the DIRECT ANALYSIS definition, you are required to key in certain controlling parameters for the analysis which is done as part of the Direct Analysis definitions. One of these parameters is the FYLD parameter which is used subsequently by the software in computing the Taub values ( equation C2-2b of the AISC 360-10 specifications). The value that you use for the FYLD should be consistent with your input unit settings that you used when defining the parameter. The error would show up if there is an inconsistency between the value you provided and the units you used. For example if your input units were “inch Kip”, you are expected to put in a value for FYLD of 50 or 36 or 48 etc. However if you define it as 7200, you would get the error. The software does an internal check and tries to make you aware of this discrepancy by issuing this warning.

    • ERROR- FYLD OUTSIDE THE NORMAL RANGE FOR STEEL
    • Share
    • History
    • More
    • Cancel
    • Sye Created by Bentley Colleague Sye
    • When: Thu, Apr 23 2015 2:28 PM
    • Modestas Last revision by Bentley Colleague Modestas
    • When: Tue, Apr 25 2023 7:58 AM
    • Revisions: 3
    • Comments: 0
    Recommended
    Related
    Communities
    • Home
    • Getting Started
    • Community Central
    • Products
    • Support
    • Secure File Upload
    • Feedback
    Support and Services
    • Home
    • Product Support
    • Downloads
    • Subscription Services Portal
    Training and Learning
    • Home
    • About Bentley Institute
    • My Learning History
    • Reference Books
    Social Media
    •    LinkedIn
    •    Facebook
    •    Twitter
    •    YouTube
    •    RSS Feed
    •    Email

    © 2023 Bentley Systems, Incorporated  |  Contact Us  |  Privacy |  Terms of Use  |  Cookies