Bentley Communities
Bentley Communities
  • Site
  • User
  • Site
  • Search
  • User
RAM | STAAD | ADINA
  • Product Communities
RAM | STAAD | ADINA
RAM | STAAD | ADINA Wiki Program Crash after Changing Beam Size in View/Update Dialog in RAM Frame - Steel Mode
    • Sign In
    • -RAM | STAAD | ADINA Wiki
      • +ADINA
      • +iTwin Analytical Synchronizer_
      • +Structural Analysis Support Solutions
      • +RAM Concept
      • +RAM Connection
      • +RAM Elements
      • +RAM SBeam
      • -RAM Structural System
        • +RAM Structural System - Feature Articles
        • RAM Structural System V17.0 License Consolidation
        • +RAM Structural System Release Notes
        • -RAM Structural System Support Solutions
          • +RAM Structural System - General Topics
          • +RAM Structural System - RAM Concrete
          • +RAM Structural System - RAM Foundation
          • -RAM Structural System - RAM Frame
            • ASCE 7, AISC 360, and the Direct Analysis Method in the RAM Structural System
            • ASCE 7, AISC 360, and the Effective Length Method in the RAM Structural System
            • CoreBrace Buckling Restrained Braces
            • Earth Pressure in RAM Structural System
            • Missing Load Cases from Generated RAM Frame Load Combinations
            • Program Crash after Changing Beam Size in View/Update Dialog in RAM Frame - Steel Mode
            • RAM Frame - Additional Lateral Restraint
            • +RAM Frame - Building and Frame Story Shear
            • RAM Frame - Center of Rigidity
            • RAM Frame - Criteria - B1 & B2
            • +RAM Frame - Criteria - Diaphragms
            • RAM Frame - Diaphragm Constraints and Gravity Forces in Shear Walls
            • RAM Frame - DXF
            • RAM Frame - Dynamic Analysis FAQ
            • RAM Frame - Eigenvalue Error [TN]
            • +RAM Frame - Load Cases
            • RAM Frame - Masses
            • RAM Frame - Notional Loads
            • RAM Frame - Overlapping Node Numbers in Plan View
            • RAM Frame - Rigid Diaphragm Constraints and Frame Shear [TN]
            • RAM Frame - Rigid End Zone assumptions
            • RAM Frame - Second Order Effects with BS 5950-1:2000
            • RAM Frame - Seismic Loads [FAQ]
            • +RAM Frame - Steel Standard and Seismic Provisions
            • RAM Frame - Story Drift at Control Points
            • RAM Frame - Tension Only [FAQ]
            • RAM Frame - Wind Loads [FAQ]
            • RAM Frame Analysis Stalls
            • RAM Frame Numbers
            • RAM Frame P-Delta [TN]
            • +RAM Frame Troubleshooting [TN]
            • RAM Frame Wall Groups FAQ
            • RAM Instability In Finite Element Analysis [TN]
            • RAM Meshing and Segmentation [TN]
            • RAMSS Truss Modeling And Design [TN]
            • +Red Status Lights for Lateral Load Cases in RAM Frame
          • +RAM Structural System - RAM Modeler
          • +RAM Structural System - RAM Steel
          • +RAM Structural System Tutorial
          • +What is RAM DataAccess? [TN]
        • +Known Issues in Ram Structural System
        • +Recordings from past RAM webinars
      • +STAAD.Pro
      • +STAAD Foundation Advanced
      • +STAAD Advanced Concrete Design (RCDC)
      • +STAAD.building
      • +STAAD RCDC FE
      • +Scenario Services
      • +STAAD.offshore
      • +Limcon
      • +Microstran
      • +MStower
      • +Structural Dashboard
      • +Structural WorkSuite
    • +RAM | STAAD Learning Resources
    • Simplifications to Bentley's Engineering Simulation Software Licenses

     
     Questions about this article, topic, or product? Click here. 

    Program Crash after Changing Beam Size in View/Update Dialog in RAM Frame - Steel Mode

       
      Applies To 
       
      Product(s): RAM Frame Analysis
      Version(s): 14.07.01.01
      Environment:  N/A
      Area:  Analysis
      Subarea: 
      Original Author: Bentley Technical Support Group
       

    Problem

    After changing a beam size in the view/update dialog in RAM Frame - Steel model and returning to RAM Frame - Analysis mode to run the analysis again, the analysis completes but then crashes with the error message below after clicking the OK button to close the Analysis dialog.

    After closing the program, the RAM Frame module no longer opens.

    The issue is associated with beams with SidePlate connections assigned to them.

    Program Defect #278236 has been logged for this issue.

    How to Avoid

    Use one of the following to bypass the crash:

    1. Assign the new beam size in RAM Frame - Analysis mode instead of the view/update dialog in RAM Frame.
    2. After changing the beam size in the view/update dialog in RAM Frame - Steel mode, exit RAM Frame and force a reframe of the model using the instructions in the Section "Forcing a Reframe" on the following web page:

    • analysis
    • RAM Frame
    • RAM Structural System
    • crash
    • beam size
    • SidePlate
    • Share
    • History
    • More
    • Cancel
    • Karl G Created by Bentley Colleague Karl G
    • When: Fri, Sep 4 2015 9:58 AM
    • Revisions: 1
    • Comments: 0
    Recommended
    Related
    Communities
    • Home
    • Getting Started
    • Community Central
    • Products
    • Support
    • Secure File Upload
    • Feedback
    Support and Services
    • Home
    • Product Support
    • Downloads
    • Subscription Services Portal
    Training and Learning
    • Home
    • About Bentley Institute
    • My Learning History
    • Reference Books
    Social Media
    •    LinkedIn
    •    Facebook
    •    Twitter
    •    YouTube
    •    RSS Feed
    •    Email

    © 2023 Bentley Systems, Incorporated  |  Contact Us  |  Privacy |  Terms of Use  |  Cookies