RAM | STAAD | ADINA Wiki RAM Concrete Column Hangs and then Crashes During Design
    • Sign In
    • -RAM | STAAD | ADINA Wiki
      • +ADINA
      • +iTwin Analytical Synchronizer_
      • +Structural Analysis Support Solutions
      • +RAM Concept
      • +RAM Connection
      • +RAM Elements
      • +RAM SBeam
      • -RAM Structural System
        • +RAM Structural System - Feature Articles
        • RAM Structural System V17.0 License Consolidation
        • +RAM Structural System Release Notes
        • +RAM Structural System Support Solutions
        • -Known Issues in Ram Structural System
          • +RAM SS - V8i Version 14.07 Issues
          • +RAM SS - CONNECT Version 15.00 Issues
          • -RAM SS - CONNECT Version 15.02 Issues
            • Eurocode Section Classification for Section Subject to Flexure Only
            • Overlapping Surface Loads on Two-Way Decks Ignored in RAM Frame and RAM Concrete
            • RAM Concrete Column Hangs and then Crashes During Design
            • Reframe causes previous passing composite girder designs to fail
          • +RAM SS - CONNECT Version 15.03 Issues
          • +RAM SS - CONNECT Version 15.04 issues
          • +RAM SS - CONNECT Version 15.05 Issues
          • +RAM SS - CONNECT Version 15.11 Issues
          • +RAM SS - CONNECT Version 16.00 Issues
          • +RAM SS - CONNECT Version 17.00 Issues
          • +RAM SS - CONNECT Version 17.01 Issues
          • +RAM SS - CONNECT Version 17.02 Issues
          • +RAM SS - CONNECT Version 17.04 Issues
        • +Recordings from past RAM webinars
      • +STAAD.Pro
      • +STAAD Foundation Advanced
      • +STAAD Advanced Concrete Design (RCDC)
      • +STAAD.building
      • +STAAD RCDC FE
      • +Scenario Services
      • +STAAD.offshore
      • +Limcon
      • +Microstran
      • +MStower
      • +Structural Dashboard
      • +Structural WorkSuite
    • +RAM | STAAD Learning Resources
    • Simplifications to Bentley's Engineering Simulation Software Licenses

     
     Questions about this article, topic, or product? Click here. 

    RAM Concrete Column Hangs and then Crashes During Design

      Applies To 
      Product: RAM Concrete Column
    First Affected Version: 15.02.00.00
      Found in Version: 15.02.00.00
    Released in Version: 15.03.00.00
      Area:  Design
      Issue #: 475167

    Problem Description

    The program hangs and then crashes producing a MFC Application Error when attempting to design concrete columns using either Process - Design All or Process - View/Update.

    In affected models, the columns can be designed once successfully. The problem occurs when attempting to design the columns or view/update after the initial design.

    Reason

    The program is checking that a valid set of bar patterns is assigned and is caught in an infinite loop.

    Solution

    Fixed in version 15.03.00.00 (August 2016) 

    For users who cannot update the version for some reason, the following file, RamConcreteColumn.dll can be used on machines running version 15.02.00.00 x64 only (32 users should submit a service request to get a 32 bit version). To use the file download it to the hard drive and replace the file in the Ram Structural System program directory, normally located here:

    C:\Program Files\Bentley\Engineering\RAM Structural System\Prog

    There is no need to register the file, but we do recommend making a backup copy of the original file first.

    The following process may also be used as a work-around:

    1. In RAM Concrete - Concrete Column, clear the column designs by clicking on Process - Clear Column Line - All.
    2. Force a reframe of the model. This can be done by changing a setting in RAM Manager - Criteria - Member Loads, clicking OK to accept the change, and then re-opening dialog and changing the setting back.
    3. Re-run the analyses in each module.
    4. Design concrete columns.

    The problem will occur again after the columns are re-designed, however.

    • First 15.02.00
    • RAM Structural System
    • crash
    • 15.03.00
    • known issue
    • defect
    • Column Design
    • Ram Concrete
    • MFC application error
    • Share
    • History
    • More
    • Cancel
    • Karl G Created by Bentley Colleague Karl G
    • When: Wed, Jun 15 2016 3:21 PM
    • Seth Guthrie Last revision by Bentley Colleague Seth Guthrie
    • When: Wed, Oct 26 2016 12:49 PM
    • Revisions: 8
    • Comments: 0
    Recommended
    Related
    Communities
    • Home
    • Getting Started
    • Community Central
    • Products
    • Support
    • Secure File Upload
    • Feedback
    Support and Services
    • Home
    • Product Support
    • Downloads
    • Subscription Services Portal
    Training and Learning
    • Home
    • About Bentley Institute
    • My Learning History
    • Reference Books
    Social Media
    •    LinkedIn
    •    Facebook
    •    Twitter
    •    YouTube
    •    RSS Feed
    •    Email

    © 2023 Bentley Systems, Incorporated  |  Contact Us  |  Privacy |  Terms of Use  |  Cookies