Bentley Communities
Site
Search
User
Site
Search
User
Product Communities
RAM | STAAD | ADINA
RAM | STAAD | ADINA Wiki
THE VALUE OF MOMENT AMPLIFICATION FACTORS KY OR KZ IS GREATER THAN 1.4
Sign In
-
RAM | STAAD | ADINA Wiki
+
ADINA
+
iTwin Analytical Synchronizer_
+
Structural Analysis Support Solutions
+
RAM Concept
+
RAM Connection
+
RAM Elements
+
RAM SBeam
+
RAM Structural System
-
STAAD.Pro
+
Revision History
-
STAAD.Pro Support Solutions
STAAD.Pro Safety Related Features
-
Analytical Modeling workflow
+
STAAD.Pro Analysis Solutions
-
STAAD.Pro Design Solutions
+
STAAD.Pro Aluminum Design
+
STAAD.Pro Concrete Design
+
STAAD.Pro General Design Solutions
-
STAAD.Pro Steel Design
+
American Steel Design Codes AISC
+
API 2A-WSD 21st Edition
+
British Steel Design code BS 5950-1:2000
+
Canadian Steel Code S16
+
European Steel Design code EN 1993-1-1-2005 (EC3)
+
General Steel Design Solutions
-
Indian Steel Design codes IS 800
Addendum-1 to IS:800-2007
BASIC SECTION DIMENSONS HAVE NOT BEEN PROVIDED. MEMBER # XXX CANNOT BE DESIGNED
Deflection check of member # xx will not be performed as service envelope not provided
Design of User defined section according to IS800:2007 code
Load Case # XX is already defined in a previous envelope. The load case of final envelope type will override previous envelope type attributes
MEMBER - XXX IS SLENDER AND CANNOT BE CHECKED FOR MOMENT FORCES
MINIMUM WEB THICKNESS REQUIREMENT FOR SERVICEABILITY NOT ACHIEVED
Reason for difference in UC ratio for symmetrical model
Serviceability Check in Design According to IS800:2007
STP Parameter per IS:800-2007
THE VALUE OF MOMENT AMPLIFICATION FACTORS KY OR KZ IS GREATER THAN 1.4
Warning - The value of Fyld for member (cable) does not seem to be right
Warning appears ‘The value of Fyld for member (cable) does not seem to be right’ during analysis
+
Verification Problems for Steel Design Codes
+
STAAD.Pro Timber Design
+
STAAD.Pro General Solutions
+
STAAD.Pro Import/Export Solutions
+
STAAD.Pro Modeling Solutions
+
Building Planner workflow
+
Connection Design workflow
+
Physical Modeling workflow
+
Piping workflow
+
Postprocessing workflow
+
Reports workflow
+
Steel AutoDrafter workflow
+
STAAD.Pro OpenSTAAD
+
(+) Archived Wikis
+
STAAD.Pro - Known Issues
+
STAAD.Pro Download/Installation/Performance/Security
+
STAAD.Pro Licensing Solutions
+
STAAD.Pro Webinars/Videos/Events
+
STAAD Advanced Concrete Design (RCDC)
+
STAAD.building
+
STAAD RCDC FE
+
Scenario Services
+
STAAD.offshore
+
Limcon
+
Microstran
+
MStower
+
Structural Dashboard
+
Structural WorkSuite
+
STAAD Foundation Advanced (SFA)
+
RAM | STAAD Learning Resources
Simplifications to Bentley's Engineering Simulation Software Licenses
THE VALUE OF MOMENT AMPLIFICATION FACTORS KY OR KZ IS GREATER THAN 1.4
Revision
Creation Date
Revision Author
Select All
Current Revision
Tue, Jun 6 2023 2:52 AM
Abhisek M
13
Revision #13
Thu, Apr 27 2023 7:27 AM
Modestas
12
Revision #12
Fri, Oct 8 2021 3:02 PM
Surojit Ghosh
11
Revision #11
Tue, Jun 25 2019 4:46 AM
Surojit Ghosh
10
Revision #10
Tue, Jun 25 2019 4:33 AM
Surojit Ghosh
9
Revision #9
Tue, Jun 25 2019 4:32 AM
Surojit Ghosh
8
Revision #8
Tue, Jun 25 2019 4:29 AM
Surojit Ghosh
7
Revision #7
Sun, May 28 2017 5:23 AM
Surojit Ghosh
6
Revision #6
Fri, Aug 12 2016 6:14 AM
Surojit Ghosh
5
Revision #5
Wed, Aug 10 2016 4:29 AM
Surojit Ghosh
4
Revision #4
Wed, Aug 10 2016 2:49 AM
Surojit Ghosh
>
Compare Versions
View current version