<?xml version="1.0" encoding="UTF-8" ?>
<?xml-stylesheet type="text/xsl" href="https://communities.bentley.com/cfs-file/__key/system/syndication/rss.xsl" media="screen"?><rss version="2.0" xmlns:dc="http://purl.org/dc/elements/1.1/"><channel><title>ACI 318 Shear Design Multi-Story Concrete Columns Seismic Design</title><link>https://communities.bentley.com/products/ram-staad/w/structural_analysis_and_design__wiki/31305/aci-318-shear-design-multi-story-concrete-columns-seismic-design</link><description /><dc:language>en-US</dc:language><generator>Telligent Community 12</generator><item><title>ACI 318 Shear Design Multi-Story Concrete Columns Seismic Design</title><link>https://communities.bentley.com/products/ram-staad/w/structural_analysis_and_design__wiki/31305/aci-318-shear-design-multi-story-concrete-columns-seismic-design</link><pubDate>Thu, 20 Oct 2016 18:46:12 GMT</pubDate><guid isPermaLink="false">6dad98f5-dbc9-4c4d-a9ba-e9da8dc6aa8e:c8804405-9cbd-438a-a6df-edc42be5f1a5</guid><dc:creator>Seth Guthrie</dc:creator><comments>https://communities.bentley.com/products/ram-staad/w/structural_analysis_and_design__wiki/31305/aci-318-shear-design-multi-story-concrete-columns-seismic-design#comments</comments><description>Current Revision posted to RAM | STAAD | ADINA Wiki by Seth Guthrie on 10/20/2016 6:46:12 PM&lt;br /&gt;
&lt;p style="padding:0;margin:0;"&gt;&lt;/p&gt;
&lt;table align="left" style="border:0px solid #dce5f0;width:500px;background-color:#dce5f0;" border="0"&gt;
&lt;tbody&gt;
&lt;tr&gt;
&lt;td style="text-align:right;"&gt;&lt;b&gt;&amp;nbsp;&lt;/b&gt;&lt;/td&gt;
&lt;td style="text-align:left;"&gt;&lt;span style="text-decoration:underline;"&gt;&lt;strong&gt;Applies To&lt;span style="font-size:medium;"&gt;&amp;nbsp;&lt;/span&gt;&lt;/strong&gt;&lt;/span&gt;&lt;/td&gt;
&lt;td&gt;&lt;/td&gt;
&lt;td&gt;&lt;/td&gt;
&lt;/tr&gt;
&lt;tr&gt;
&lt;td style="text-align:right;"&gt;&lt;strong&gt;&amp;nbsp;&lt;/strong&gt;&lt;/td&gt;
&lt;td style="text-align:right;"&gt;&lt;strong&gt;Product:&lt;/strong&gt;&lt;/td&gt;
&lt;td&gt;RAM Concrete&lt;/td&gt;
&lt;td&gt;&lt;/td&gt;
&lt;/tr&gt;
&lt;tr&gt;
&lt;td style="text-align:right;"&gt;&lt;strong&gt;&lt;/strong&gt;&lt;/td&gt;
&lt;td style="text-align:right;"&gt;&lt;strong&gt;First Affected Version:&lt;/strong&gt;&lt;/td&gt;
&lt;td&gt;&lt;/td&gt;
&lt;td&gt;&lt;/td&gt;
&lt;/tr&gt;
&lt;tr&gt;
&lt;td style="text-align:right;"&gt;&lt;strong&gt;&amp;nbsp;&lt;/strong&gt;&lt;/td&gt;
&lt;td style="text-align:right;"&gt;&lt;strong&gt;Found in Version:&lt;/strong&gt;&lt;/td&gt;
&lt;td&gt;14.06.02.00&lt;/td&gt;
&lt;td&gt;&lt;/td&gt;
&lt;/tr&gt;
&lt;tr&gt;
&lt;td style="text-align:right;"&gt;&lt;strong&gt;&lt;/strong&gt;&lt;/td&gt;
&lt;td style="text-align:right;"&gt;&lt;strong&gt;Fixed in Version:&lt;/strong&gt;&lt;/td&gt;
&lt;td&gt;&lt;/td&gt;
&lt;td&gt;&lt;/td&gt;
&lt;/tr&gt;
&lt;tr&gt;
&lt;td style="text-align:right;"&gt;&lt;strong&gt;&amp;nbsp;&lt;/strong&gt;&lt;/td&gt;
&lt;td style="text-align:right;"&gt;&lt;strong&gt;Area:&amp;nbsp;&lt;/strong&gt;&lt;/td&gt;
&lt;td&gt;Design&lt;/td&gt;
&lt;td&gt;&lt;/td&gt;
&lt;/tr&gt;
&lt;tr&gt;
&lt;td style="text-align:right;"&gt;&lt;strong&gt;&amp;nbsp;&lt;/strong&gt;&lt;/td&gt;
&lt;td style="text-align:right;"&gt;&lt;strong&gt;Issue #:&lt;/strong&gt;&lt;/td&gt;
&lt;td&gt;123374&lt;/td&gt;
&lt;td&gt;&lt;/td&gt;
&lt;/tr&gt;
&lt;/tbody&gt;
&lt;/table&gt;
&lt;h1&gt;Problem Description&lt;/h1&gt;
&lt;p&gt;The program designed concrete columns for an incorrect shear demand (Vu) when all of the following conditions occurred:&lt;/p&gt;
&lt;ol&gt;
&lt;li&gt;The columns spanned multiple stories.&lt;/li&gt;
&lt;li&gt;The columns were not braced by beams at the intermediate levels.&lt;/li&gt;
&lt;li&gt;The columns were part of a intermediate or special moment frame.&lt;/li&gt;
&lt;/ol&gt;
&lt;p&gt;The problem affected all ACI design codes.&lt;/p&gt;
&lt;h1&gt;Reason&lt;/h1&gt;
&lt;p&gt;Columns that are part of intermediate or special moment frames must be designed for a shear demand associated with probable flexural strength (Mpr). When determining Mpr, the program looked at the top and bottom of each column segment and did not consider the bracing condition at each end of the segment. When one&amp;nbsp;end of the segment was not braced, as would occur when no beam frame into the column, the program returned a value of 0 for Mpr.&lt;/p&gt;
&lt;p&gt;&lt;/p&gt;
&lt;h1&gt;Solution&lt;/h1&gt;
&lt;p&gt;We are working on a fix for this problem.&lt;/p&gt;
&lt;p&gt;&lt;/p&gt;
&lt;p&gt;&lt;b&gt;&lt;img width="189" height="60" alt=" " src="/cfs-file.ashx/__key/communityserver-components-sitefiles/TSG-Logo.png" /&gt;&lt;/b&gt;&lt;/p&gt;&lt;div style="clear:both;"&gt;&lt;/div&gt;

&lt;div style="font-size: 90%;"&gt;Tags: Active, design, Column, RAM Structural System, Shear, ACI 318, known issue, seismic, defect, Ram Concrete&lt;/div&gt;
</description></item><item><title>ACI 318 Shear Design Multi-Story Concrete Columns Seismic Design</title><link>https://communities.bentley.com/products/ram-staad/w/structural_analysis_and_design__wiki/31305/aci-318-shear-design-multi-story-concrete-columns-seismic-design/revision/1</link><pubDate>Wed, 19 Oct 2016 19:42:14 GMT</pubDate><guid isPermaLink="false">6dad98f5-dbc9-4c4d-a9ba-e9da8dc6aa8e:c8804405-9cbd-438a-a6df-edc42be5f1a5</guid><dc:creator>Karl G</dc:creator><comments>https://communities.bentley.com/products/ram-staad/w/structural_analysis_and_design__wiki/31305/aci-318-shear-design-multi-story-concrete-columns-seismic-design#comments</comments><description>Revision 1 posted to RAM | STAAD | ADINA Wiki by Karl G on 10/19/2016 7:42:14 PM&lt;br /&gt;
&lt;p style="padding:0;margin:0;"&gt;&lt;/p&gt;
&lt;table align="left" style="border:0px solid #dce5f0;width:500px;background-color:#dce5f0;" border="0"&gt;
&lt;tbody&gt;
&lt;tr&gt;
&lt;td style="text-align:right;"&gt;&lt;b&gt;&amp;nbsp;&lt;/b&gt;&lt;/td&gt;
&lt;td style="text-align:left;"&gt;&lt;span style="text-decoration:underline;"&gt;&lt;strong&gt;Applies To&lt;span style="font-size:medium;"&gt;&amp;nbsp;&lt;/span&gt;&lt;/strong&gt;&lt;/span&gt;&lt;/td&gt;
&lt;td&gt;&lt;/td&gt;
&lt;td&gt;&lt;/td&gt;
&lt;/tr&gt;
&lt;tr&gt;
&lt;td style="text-align:right;"&gt;&lt;strong&gt;&amp;nbsp;&lt;/strong&gt;&lt;/td&gt;
&lt;td style="text-align:right;"&gt;&lt;strong&gt;Product:&lt;/strong&gt;&lt;/td&gt;
&lt;td&gt;RAM Concrete&lt;/td&gt;
&lt;td&gt;&lt;/td&gt;
&lt;/tr&gt;
&lt;tr&gt;
&lt;td style="text-align:right;"&gt;&lt;strong&gt;&lt;/strong&gt;&lt;/td&gt;
&lt;td style="text-align:right;"&gt;&lt;strong&gt;First Affected Version:&lt;/strong&gt;&lt;/td&gt;
&lt;td&gt;&lt;/td&gt;
&lt;td&gt;&lt;/td&gt;
&lt;/tr&gt;
&lt;tr&gt;
&lt;td style="text-align:right;"&gt;&lt;strong&gt;&amp;nbsp;&lt;/strong&gt;&lt;/td&gt;
&lt;td style="text-align:right;"&gt;&lt;strong&gt;Found in Version:&lt;/strong&gt;&lt;/td&gt;
&lt;td&gt;14.06.02.00&lt;/td&gt;
&lt;td&gt;&lt;/td&gt;
&lt;/tr&gt;
&lt;tr&gt;
&lt;td style="text-align:right;"&gt;&lt;strong&gt;&lt;/strong&gt;&lt;/td&gt;
&lt;td style="text-align:right;"&gt;&lt;strong&gt;Fixed in Version:&lt;/strong&gt;&lt;/td&gt;
&lt;td&gt;&lt;/td&gt;
&lt;td&gt;&lt;/td&gt;
&lt;/tr&gt;
&lt;tr&gt;
&lt;td style="text-align:right;"&gt;&lt;strong&gt;&amp;nbsp;&lt;/strong&gt;&lt;/td&gt;
&lt;td style="text-align:right;"&gt;&lt;strong&gt;Area:&amp;nbsp;&lt;/strong&gt;&lt;/td&gt;
&lt;td&gt;Design&lt;/td&gt;
&lt;td&gt;&lt;/td&gt;
&lt;/tr&gt;
&lt;tr&gt;
&lt;td style="text-align:right;"&gt;&lt;strong&gt;&amp;nbsp;&lt;/strong&gt;&lt;/td&gt;
&lt;td style="text-align:right;"&gt;&lt;strong&gt;Issue #:&lt;/strong&gt;&lt;/td&gt;
&lt;td&gt;123374&lt;/td&gt;
&lt;td&gt;&lt;/td&gt;
&lt;/tr&gt;
&lt;/tbody&gt;
&lt;/table&gt;
&lt;h1&gt;Problem Description&lt;/h1&gt;
&lt;p&gt;The program designed concrete columns for an incorrect shear demand (Vu) when all of the following conditions occurred:&lt;/p&gt;
&lt;ol&gt;
&lt;li&gt;The columns spanned multiple stories.&lt;/li&gt;
&lt;li&gt;The columns were not braced by beams at the intermediate levels.&lt;/li&gt;
&lt;li&gt;The columns were part of a intermediate or special moment frame.&lt;/li&gt;
&lt;/ol&gt;
&lt;p&gt;The problem affected all ACI design codes.&lt;/p&gt;
&lt;h1&gt;Reason&lt;/h1&gt;
&lt;p&gt;Columns that are part of intermediate or special moment frames must be designed for a shear demand associated with probable flexural strength (Mpr). When determining Mpr, the program looked at the top and bottom of each column segment and did not consider the bracing condition at each end of the segment. When one&amp;nbsp;end of the segment was not braced, as would occur when no beam frame into the column, the program returned a value of 0 for Mpr.&lt;/p&gt;
&lt;p&gt;&lt;/p&gt;
&lt;h1&gt;Solution&lt;/h1&gt;
&lt;p&gt;We are working on a fix for this problem.&lt;/p&gt;
&lt;p&gt;&lt;/p&gt;
&lt;p&gt;&lt;b&gt;&lt;img width="189" height="60" alt=" " src="/cfs-file.ashx/__key/communityserver-components-sitefiles/TSG-Logo.png" /&gt;&lt;/b&gt;&lt;/p&gt;&lt;div style="clear:both;"&gt;&lt;/div&gt;

&lt;div style="font-size: 90%;"&gt;Tags: design, Column, RAM Structural System, Shear, ACI 318, known issue, seismic, defect, Ram Concrete&lt;/div&gt;