Axial force at intermediate section locations incorrect for REPEAT LOADs including cases with self w


 Applies To 
 Product:STAAD.Pro
First Affected Version:
 Found in Version:20.07.11.50
Released in Version:20.07.11.82
Environment:All
 Area: Post processing
Subarea:N/A
 Issue #:392114

Problem Description

If any primary load case containing self weight is included in a Repeat Load case, the effect of self weight on axial force calculation is ignored at intermediate sections, thereby producing incorrect axial forces at intermediate section locations for the Repeat Load case. The values at the start and end of the member are correct.

Steps to Reproduce

  1. Define a REPEAT LOAD with a case that has self weight defined as part of it.
  2. Check the axial force at intermediate section locations for that REPEAT LOAD case.

Workaround

None

Solution

This is addressed in 20.07.11.82

See Also