Applies To | |||
Product: | STAAD.Pro | ||
First Affected Version: | 20.07.11.33 | ||
Found in Version: | 20.07.11.33 | ||
Released in Version: | 20.07.11.47 | ||
Environment: | All | ||
Area: | Design | ||
Subarea: | AISC 360, AISC 341 | ||
Issue #: | 314845 |
Design of angles and Tees fail as per the AISC code when seismic provisions of AISC 341 are checked. With SEI set to 1, error messages like the ones below are obtained for angles and tee sections
ERROR: MEMBER DESIGN FAILED FOR MEMBER 378
ERROR: MEMBER DESIGN FAILED FOR MEMBER 379
.
There is currently no workaround other than commenting out the seismic checks for these sections.
This issue was released in version 20.07.11.47