Applies To | |||
Product: | STAAD.Pro | ||
First Affected Version: | |||
Found in Version: | 20.07.10.65 | ||
Released in Version: | 20.07.11.45 | ||
Environment: | All | ||
Area: | Design | ||
Subarea: | AISC 360-05/10, IS800-2007 and CSA S16-09/14 | ||
Issue #: | 257528 |
When multiple tapered members are designed in group with CHECK CODE ALL command vs. designed individually, the design results do not match. Noted for multiple codes like AISC 360-05/10 / IS800-2007/ S16- 09/14.
Run an appropriate model with Tapered member and check the results of design for the two cases
a. using an individual CHECK CODE for each member
b. using a CHECK CODE for a LIST of members
Results seem to differ.
.
The only option for now is to design these tapered members individually using CHECK CODE MEMB ... command
The issue is addressed in 20.07.11.45