Applies To | |||
Product: | STAAD.Pro | ||
First Affected Version: | |||
Found in Version: | 20.07.11.33 | ||
Released in Version: | 20.07.11.45 | ||
Environment: | All | ||
Area: | Modeling | ||
Subarea: | AISC_14.1 | ||
Issue #: | 257492, 257533 |
It has been noted that the AISC 14.1 section profile database that is delivered with STAAD.Pro V8i SS6 (20.07.11.33) has a couple of issues :-
1) Models that include standard or extra strong pipe sections. These had been assigned incorrect STAAD names and thus a standard profile would be assigned a extra strong property and an extra strong profile would be assigned the standard property.
2) The first few profiles listed in the wide flange 'W Shape' table are new heavy sections and added to the database with a space in the STAAD name which when assigned to a model would cause the analysis engine to crash.
.
.
A corrected version of the database can be downloaded from here
The issue is addressed in 20.07.11.45