<?xml version="1.0" encoding="UTF-8" ?>
<?xml-stylesheet type="text/xsl" href="https://communities.bentley.com/cfs-file/__key/system/syndication/rss.xsl" media="screen"?><rss version="2.0" xmlns:dc="http://purl.org/dc/elements/1.1/"><channel><title>Issues with the AISC 14.1 Profile Database</title><link>https://communities.bentley.com/products/ram-staad/w/structural_analysis_and_design__wiki/31940/issues-with-the-aisc-14-1-profile-database</link><description /><dc:language>en-US</dc:language><generator>Telligent Community 12</generator><item><title>Issues with the AISC 14.1 Profile Database</title><link>https://communities.bentley.com/products/ram-staad/w/structural_analysis_and_design__wiki/31940/issues-with-the-aisc-14-1-profile-database</link><pubDate>Thu, 01 Dec 2016 01:36:48 GMT</pubDate><guid isPermaLink="false">6dad98f5-dbc9-4c4d-a9ba-e9da8dc6aa8e:92a14108-820b-4710-8797-5c79e2f68b59</guid><dc:creator>Sye</dc:creator><comments>https://communities.bentley.com/products/ram-staad/w/structural_analysis_and_design__wiki/31940/issues-with-the-aisc-14-1-profile-database#comments</comments><description>Current Revision posted to RAM | STAAD | ADINA Wiki by Sye on 12/1/2016 1:36:48 AM&lt;br /&gt;
&lt;h2&gt;&lt;/h2&gt;
&lt;p style="padding:0;margin:0;"&gt;&lt;/p&gt;
&lt;table align="left" style="border:0px solid #dce5f0;width:500px;background-color:#dce5f0;" border="0"&gt;
&lt;tbody&gt;
&lt;tr&gt;
&lt;td style="text-align:right;"&gt;&lt;b&gt;&amp;nbsp;&lt;/b&gt;&lt;/td&gt;
&lt;td style="text-align:left;"&gt;&lt;span style="text-decoration:underline;"&gt;&lt;strong&gt;Applies To&lt;span style="font-size:medium;"&gt;&amp;nbsp;&lt;/span&gt;&lt;/strong&gt;&lt;/span&gt;&lt;/td&gt;
&lt;td&gt;&lt;/td&gt;
&lt;td&gt;&lt;/td&gt;
&lt;/tr&gt;
&lt;tr&gt;
&lt;td style="text-align:right;"&gt;&lt;strong&gt;&amp;nbsp;&lt;/strong&gt;&lt;/td&gt;
&lt;td style="text-align:right;"&gt;&lt;strong&gt;Product:&lt;/strong&gt;&lt;/td&gt;
&lt;td&gt;STAAD.Pro&lt;/td&gt;
&lt;td&gt;&lt;/td&gt;
&lt;/tr&gt;
&lt;tr&gt;
&lt;td style="text-align:right;"&gt;&lt;strong&gt;&lt;/strong&gt;&lt;/td&gt;
&lt;td style="text-align:right;"&gt;&lt;strong&gt;First Affected Version:&lt;/strong&gt;&lt;/td&gt;
&lt;td&gt;&lt;/td&gt;
&lt;td&gt;&lt;/td&gt;
&lt;/tr&gt;
&lt;tr&gt;
&lt;td style="text-align:right;"&gt;&lt;strong&gt;&amp;nbsp;&lt;/strong&gt;&lt;/td&gt;
&lt;td style="text-align:right;"&gt;&lt;strong&gt;Found in Version:&lt;/strong&gt;&lt;/td&gt;
&lt;td&gt;20.07.11.33&lt;/td&gt;
&lt;td&gt;&lt;/td&gt;
&lt;/tr&gt;
&lt;tr&gt;
&lt;td style="text-align:right;"&gt;&lt;strong&gt;&lt;/strong&gt;&lt;/td&gt;
&lt;td style="text-align:right;"&gt;&lt;strong&gt;Released in Version:&lt;/strong&gt;&lt;/td&gt;
&lt;td&gt;20.07.11.45&lt;/td&gt;
&lt;td&gt;&lt;/td&gt;
&lt;/tr&gt;
&lt;tr&gt;
&lt;td style="text-align:right;"&gt;&lt;strong&gt;&lt;/strong&gt;&lt;/td&gt;
&lt;td style="text-align:right;margin-left:30px;"&gt;&lt;strong&gt;Environment:&lt;/strong&gt;&lt;/td&gt;
&lt;td&gt;All&lt;/td&gt;
&lt;td&gt;&lt;/td&gt;
&lt;/tr&gt;
&lt;tr&gt;
&lt;td style="text-align:right;"&gt;&lt;strong&gt;&amp;nbsp;&lt;/strong&gt;&lt;/td&gt;
&lt;td style="text-align:right;"&gt;&lt;strong&gt;Area:&amp;nbsp;&lt;/strong&gt;&lt;/td&gt;
&lt;td&gt;Modeling&lt;/td&gt;
&lt;td&gt;&lt;/td&gt;
&lt;/tr&gt;
&lt;tr&gt;
&lt;td style="text-align:right;"&gt;&lt;strong&gt;&lt;/strong&gt;&lt;/td&gt;
&lt;td style="text-align:right;margin-left:30px;"&gt;&lt;strong&gt;Subarea:&lt;/strong&gt;&lt;/td&gt;
&lt;td&gt;AISC_14.1&amp;nbsp;&lt;/td&gt;
&lt;td&gt;&lt;/td&gt;
&lt;/tr&gt;
&lt;tr&gt;
&lt;td style="text-align:right;"&gt;&lt;strong&gt;&amp;nbsp;&lt;/strong&gt;&lt;/td&gt;
&lt;td style="text-align:right;"&gt;&lt;strong&gt;Issue #:&lt;/strong&gt;&lt;/td&gt;
&lt;td&gt;257492,&amp;nbsp;&amp;nbsp;257533&lt;/td&gt;
&lt;td&gt;&lt;/td&gt;
&lt;/tr&gt;
&lt;/tbody&gt;
&lt;/table&gt;
&lt;h1&gt;Problem Description&lt;/h1&gt;
&lt;p&gt;It has been noted that the AISC 14.1 section profile database that is delivered with STAAD.Pro V8i SS6 (20.07.11.33) has a couple of issues :-&lt;/p&gt;
&lt;p&gt;1) Models that include standard or extra strong pipe sections. These had been assigned incorrect STAAD names and thus a standard profile would be assigned a extra strong property and an extra strong profile would be assigned the standard property.&lt;/p&gt;
&lt;p&gt;2) The first few profiles listed in the wide flange &amp;#39;W Shape&amp;#39; table are new heavy sections and added to the database with a space in the STAAD name which when assigned to a model would cause the analysis engine to crash.&lt;/p&gt;
&lt;p&gt;.&lt;/p&gt;
&lt;h1&gt;Steps to Reproduce&lt;/h1&gt;
&lt;ol&gt;
&lt;li&gt;Open STAAD.Pro.&lt;/li&gt;
&lt;li&gt;Open Configuration &amp;ndash; Section Profile Table. Choose AISC_14.1 section database for AISC.&lt;/li&gt;
&lt;li&gt;Now open any model.&lt;/li&gt;
&lt;li&gt;Go to section database.&lt;/li&gt;
&lt;li&gt;Open AISC W sections.&lt;/li&gt;
&lt;li&gt;Try to assign any of the first 10 W sections to any member.&lt;/li&gt;
&lt;li&gt;Open the input editor.&lt;/li&gt;
&lt;li&gt;Edit it, save it and try to close the editor.&lt;/li&gt;
&lt;li&gt;Program gives error message.&lt;/li&gt;
&lt;/ol&gt;
&lt;p&gt;.&lt;/p&gt;
&lt;h1&gt;Workaround&lt;/h1&gt;
&lt;p&gt;A corrected version of the database can be downloaded from &lt;a href="https://communities.bentley.com/products/structural/structural_analysis___design/b/analysis_and_design_blog/archive/2015/07/21/staad-pro-v8i-ss6-aisc-14-1-profile-database"&gt;here&lt;/a&gt;&amp;nbsp;&lt;/p&gt;
&lt;h1&gt;Solution&lt;/h1&gt;
&lt;p&gt;The issue is addressed in 20.07.11.45&lt;/p&gt;
&lt;h1&gt;See Also&lt;/h1&gt;
&lt;p&gt;&lt;b&gt;&lt;img width="189" height="60" alt=" " src="/cfs-file.ashx/__key/communityserver-components-sitefiles/TSG-Logo.png" /&gt;&lt;/b&gt;&lt;/p&gt;&lt;div style="clear:both;"&gt;&lt;/div&gt;

&lt;div style="font-size: 90%;"&gt;Tags: STAAD.Pro, 20.07.11.45, AISC_14.1, First 20.07.11.33, known issue, defect, Database&lt;/div&gt;
</description></item><item><title>Issues with the AISC 14.1 Profile Database</title><link>https://communities.bentley.com/products/ram-staad/w/structural_analysis_and_design__wiki/31940/issues-with-the-aisc-14-1-profile-database/revision/1</link><pubDate>Thu, 01 Dec 2016 01:28:08 GMT</pubDate><guid isPermaLink="false">6dad98f5-dbc9-4c4d-a9ba-e9da8dc6aa8e:92a14108-820b-4710-8797-5c79e2f68b59</guid><dc:creator>Sye</dc:creator><comments>https://communities.bentley.com/products/ram-staad/w/structural_analysis_and_design__wiki/31940/issues-with-the-aisc-14-1-profile-database#comments</comments><description>Revision 1 posted to RAM | STAAD | ADINA Wiki by Sye on 12/1/2016 1:28:08 AM&lt;br /&gt;
&lt;h2&gt;&lt;/h2&gt;
&lt;p style="padding:0;margin:0;"&gt;&lt;/p&gt;
&lt;table align="left" style="border:0px solid #dce5f0;width:500px;background-color:#dce5f0;" border="0"&gt;
&lt;tbody&gt;
&lt;tr&gt;
&lt;td style="text-align:right;"&gt;&lt;b&gt;&amp;nbsp;&lt;/b&gt;&lt;/td&gt;
&lt;td style="text-align:left;"&gt;&lt;span style="text-decoration:underline;"&gt;&lt;strong&gt;Applies To&lt;span style="font-size:medium;"&gt;&amp;nbsp;&lt;/span&gt;&lt;/strong&gt;&lt;/span&gt;&lt;/td&gt;
&lt;td&gt;&lt;/td&gt;
&lt;td&gt;&lt;/td&gt;
&lt;/tr&gt;
&lt;tr&gt;
&lt;td style="text-align:right;"&gt;&lt;strong&gt;&amp;nbsp;&lt;/strong&gt;&lt;/td&gt;
&lt;td style="text-align:right;"&gt;&lt;strong&gt;Product:&lt;/strong&gt;&lt;/td&gt;
&lt;td&gt;STAAD.Pro&lt;/td&gt;
&lt;td&gt;&lt;/td&gt;
&lt;/tr&gt;
&lt;tr&gt;
&lt;td style="text-align:right;"&gt;&lt;strong&gt;&lt;/strong&gt;&lt;/td&gt;
&lt;td style="text-align:right;"&gt;&lt;strong&gt;First Affected Version:&lt;/strong&gt;&lt;/td&gt;
&lt;td&gt;&lt;/td&gt;
&lt;td&gt;&lt;/td&gt;
&lt;/tr&gt;
&lt;tr&gt;
&lt;td style="text-align:right;"&gt;&lt;strong&gt;&amp;nbsp;&lt;/strong&gt;&lt;/td&gt;
&lt;td style="text-align:right;"&gt;&lt;strong&gt;Found in Version:&lt;/strong&gt;&lt;/td&gt;
&lt;td&gt;20.07.11.33&lt;/td&gt;
&lt;td&gt;&lt;/td&gt;
&lt;/tr&gt;
&lt;tr&gt;
&lt;td style="text-align:right;"&gt;&lt;strong&gt;&lt;/strong&gt;&lt;/td&gt;
&lt;td style="text-align:right;"&gt;&lt;strong&gt;Released in Version:&lt;/strong&gt;&lt;/td&gt;
&lt;td&gt;20.07.11.45&lt;/td&gt;
&lt;td&gt;&lt;/td&gt;
&lt;/tr&gt;
&lt;tr&gt;
&lt;td style="text-align:right;"&gt;&lt;strong&gt;&lt;/strong&gt;&lt;/td&gt;
&lt;td style="text-align:right;margin-left:30px;"&gt;&lt;strong&gt;Environment:&lt;/strong&gt;&lt;/td&gt;
&lt;td&gt;All&lt;/td&gt;
&lt;td&gt;&lt;/td&gt;
&lt;/tr&gt;
&lt;tr&gt;
&lt;td style="text-align:right;"&gt;&lt;strong&gt;&amp;nbsp;&lt;/strong&gt;&lt;/td&gt;
&lt;td style="text-align:right;"&gt;&lt;strong&gt;Area:&amp;nbsp;&lt;/strong&gt;&lt;/td&gt;
&lt;td&gt;Modeling&lt;/td&gt;
&lt;td&gt;&lt;/td&gt;
&lt;/tr&gt;
&lt;tr&gt;
&lt;td style="text-align:right;"&gt;&lt;strong&gt;&lt;/strong&gt;&lt;/td&gt;
&lt;td style="text-align:right;margin-left:30px;"&gt;&lt;strong&gt;Subarea:&lt;/strong&gt;&lt;/td&gt;
&lt;td&gt;AISC_14.1&amp;nbsp;&lt;/td&gt;
&lt;td&gt;&lt;/td&gt;
&lt;/tr&gt;
&lt;tr&gt;
&lt;td style="text-align:right;"&gt;&lt;strong&gt;&amp;nbsp;&lt;/strong&gt;&lt;/td&gt;
&lt;td style="text-align:right;"&gt;&lt;strong&gt;Issue #:&lt;/strong&gt;&lt;/td&gt;
&lt;td&gt;257492&lt;/td&gt;
&lt;td&gt;&lt;/td&gt;
&lt;/tr&gt;
&lt;/tbody&gt;
&lt;/table&gt;
&lt;h1&gt;Problem Description&lt;/h1&gt;
&lt;p&gt;It has been noted that the AISC 14.1 section profile database that is delivered with STAAD.Pro V8i SS6 (20.07.11.33) has a couple of issues :-&lt;/p&gt;
&lt;p&gt;1) Models that include standard or extra strong pipe sections. These had been assigned incorrect STAAD names and thus a standard profile would be assigned a extra strong property and an extra strong profile would be assigned the standard property.&lt;/p&gt;
&lt;p&gt;2) The first few profiles listed in the wide flange &amp;#39;W Shape&amp;#39; table are new heavy sections and added to the database with a space in the STAAD name which when assigned to a model would cause the analysis engine to crash.&lt;/p&gt;
&lt;p&gt;.&lt;/p&gt;
&lt;h1&gt;Steps to Reproduce&lt;/h1&gt;
&lt;ol&gt;
&lt;li&gt;Open STAAD.Pro.&lt;/li&gt;
&lt;li&gt;Open Configuration &amp;ndash; Section Profile Table. Choose AISC_14.1 section database for AISC.&lt;/li&gt;
&lt;li&gt;Now open any model.&lt;/li&gt;
&lt;li&gt;Go to section database.&lt;/li&gt;
&lt;li&gt;Open AISC W sections.&lt;/li&gt;
&lt;li&gt;Try to assign any of the first 10 W sections to any member.&lt;/li&gt;
&lt;li&gt;Open the input editor.&lt;/li&gt;
&lt;li&gt;Edit it, save it and try to close the editor.&lt;/li&gt;
&lt;li&gt;Program gives error message.&lt;/li&gt;
&lt;/ol&gt;
&lt;p&gt;.&lt;/p&gt;
&lt;h1&gt;Workaround&lt;/h1&gt;
&lt;p&gt;A corrected version of the database can be downloaded from &lt;a href="https://communities.bentley.com/products/structural/structural_analysis___design/b/analysis_and_design_blog/archive/2015/07/21/staad-pro-v8i-ss6-aisc-14-1-profile-database"&gt;here&lt;/a&gt;&amp;nbsp;&lt;/p&gt;
&lt;h1&gt;Solution&lt;/h1&gt;
&lt;p&gt;The issue is addressed in 20.07.11.45&lt;/p&gt;
&lt;h1&gt;See Also&lt;/h1&gt;