RAM Concrete Shear Wall Negative Reinforcement Ratio


 Applies To 
 Product:RAM Concrete
First Affected Version:
 Found in Version:15.03.00
Fixed and Released in Version:15.04.00
 Area: Design
 Issue #:651534

Problem Description

In rare cases, the program may have reported negative horizontal and vertical reinforcement ratios. When this occurred, the program marked the section cut as failing when the reinforcement requirements satisfied code requirements.

Solution

Fixed in v15.04.00.

The issue may still occur in existing models. To resolve the issue in these models, delete and remodel all section cuts.