Bentley Communities
Bentley Communities
  • Site
  • User
  • Site
  • Search
  • User
RAM | STAAD | ADINA
  • Product Communities
RAM | STAAD | ADINA
RAM | STAAD | ADINA Wiki RAM Elements V8i (CONNECT Enabled) v13.05.00.227 Release Notes
    • Sign In
    • -RAM | STAAD | ADINA Wiki
      • +ADINA
      • +Integrated Structural Modeling
      • +Structural Analysis Support Solutions
      • +RAM Concept
      • +RAM Connection
      • -RAM Elements
        • +RAM Elements Feature Articles
        • RAM Elements Models From Users Around The World
        • Whitepapers
        • -RAM Elements Release Notes
          • RAM Advanse V9.6.X Release Notes
          • RAM Elements 10.0.1 Release Notes
          • RAM Elements CONNECT Edition v14.0.0.240 Release Notes
          • RAM Elements CONNECT Edition v14.0.1.008 Release Notes
          • RAM Elements CONNECT Edition v15.0 Release Notes
          • RAM Elements CONNECT Edition v16.0 Release Notes
          • RAM Elements CONNECT Edition v16.1 Release Notes
          • RAM Elements CONNECT Edition v16.1.1 Release Notes
          • RAM Elements CONNECT Edition v16.2 Release Notes
          • RAM Elements CONNECT Edition v16.3 Release Notes
          • RAM Elements CONNECT Edition v16.3.1 Release Notes
          • RAM Elements CONNECT Edition v16.4 Release Notes
          • RAM Elements CONNECT Edition v16.5 Release Notes
          • RAM Elements CONNECT Edition v16.6 Release Notes
          • RAM Elements CONNECT Edition v16.7 Release Notes
          • RAM Elements CONNECT Edition v16.8 Release Notes
          • RAM Elements v10.0.2 Release Notes
          • RAM Elements V10.5 Release Notes
          • RAM Elements V11.0 Release Notes
          • RAM Elements V12.0 Release Notes
          • RAM Elements V12.1 Release Notes
          • RAM Elements V12.5 Release Notes
          • RAM Elements V12.5.1 Release Notes
          • RAM Elements V12.5.2 Release Notes
          • RAM Elements V13.0 Release Notes
          • RAM Elements V13.0.3 Release Notes
          • RAM Elements V13.2.0 Release Notes
          • RAM Elements V13.3.0 Release Notes
          • RAM Elements V8i (CONNECT Enabled) v13.04.01.208 Release Notes
          • RAM Elements V8i (CONNECT Enabled) v13.05.00.227 Release Notes
          • RAM Elements V8i (CONNECT Enabled) v13.4 Release Notes
        • +RAM Elements Support Solutions
        • +Known Issues in Ram Elements
      • +RAM SBeam
      • +RAM Structural System
      • +STAAD.Pro
      • +STAAD Foundation Advanced
      • +STAAD Advanced Concrete Design (RCDC)
      • +STAAD.building
      • +STAAD RCDC FE
      • +Scenario Services
      • +STAAD.offshore
      • +Limcon
      • +Microstran
      • +MStower
      • +Structural Dashboard
      • +Structural WorkSuite
    • +RAM | STAAD Learning Resources
    • Simplifications to Bentley's Engineering Simulation Software Licenses

     
     Questions about this article, topic, or product? Click here. 

    RAM Elements V8i (CONNECT Enabled) v13.05.00.227 Release Notes

    RAM Elements V8i (CONNECT Enabled) v13.5.0 Release Notes – Updated May 2017

    Enhancements:

    1. RAM Elements now includes Bentley CONNECT Advisor v10.0.2 which is a CONNECT service enabling Bentley users to have real time access to LEARN content, recommendations for more productive workflows and the ability to embed an Expert Engineer to their CONNECTED project.

    2. Update to ISM 6.0.

    Resolved Issues:

    1. A display glitch prevented nodes from being shown on the screen after the Windows 10 Update version 1703 “Creators Update”. This has now been resolved.

    2. The Context Sensitive Help was not working for some spreadsheets in RAM Elements when pressing F1 in the keyboard. This has now been corrected and new help files have been generated.

    3. The “aw” parameter used in the computation of the buckling critical stress (Fcr) was being erroneously calculated for built-up sections. It was always calculated for rolled sections. This has now been corrected in AISC 360-05 and 10.

    4. The magnitude of distributed loads coming from area loads were incorrectly calculated. This has now been rectified.

    5. The interaction ratio of compression members with moments was being calculated per section 4.8.3.3 in all cases. This has been corrected to apply section 4.8.3.2 in both on screen and the reports. Section 4.8.3.3 is also being calculated when appropriate and reported accordingly.

    6. Other several minor fixes.
    • RAM Elements
    • release notes
    • Share
    • History
    • More
    • Cancel
    • F_Diego Created by Bentley Colleague F_Diego
    • When: Mon, May 15 2017 11:16 AM
    • F_Diego Last revision by Bentley Colleague F_Diego
    • When: Tue, May 30 2017 1:04 PM
    • Revisions: 5
    • Comments: 0
    Recommended
    Related
    Communities
    • Home
    • Getting Started
    • Community Central
    • Products
    • Support
    • Secure File Upload
    • Feedback
    Support and Services
    • Home
    • Product Support
    • Downloads
    • Subscription Services Portal
    Training and Learning
    • Home
    • About Bentley Institute
    • My Learning History
    • Reference Books
    Social Media
    •    LinkedIn
    •    Facebook
    •    Twitter
    •    YouTube
    •    RSS Feed
    •    Email

    © 2023 Bentley Systems, Incorporated  |  Contact Us  |  Privacy |  Terms of Use  |  Cookies