Bentley Communities
Bentley Communities
  • Site
  • User
  • Site
  • Search
  • User
RAM | STAAD | ADINA
  • Product Communities
RAM | STAAD | ADINA
RAM | STAAD | ADINA Wiki EC2 Concrete Column Design Reported VEd Forces
    • Sign In
    • -RAM | STAAD | ADINA Wiki
      • +ADINA
      • +iTwin Analytical Synchronizer_
      • +Structural Analysis Support Solutions
      • +RAM Concept
      • +RAM Connection
      • +RAM Elements
      • +RAM SBeam
      • -RAM Structural System
        • +RAM Structural System - Feature Articles
        • RAM Structural System V17.0 License Consolidation
        • +RAM Structural System Release Notes
        • +RAM Structural System Support Solutions
        • -Known Issues in Ram Structural System
          • +RAM SS - V8i Version 14.07 Issues
          • +RAM SS - CONNECT Version 15.00 Issues
          • +RAM SS - CONNECT Version 15.02 Issues
          • +RAM SS - CONNECT Version 15.03 Issues
          • -RAM SS - CONNECT Version 15.04 issues
            • EC2 Concrete Column Design Reported VEd Forces
            • Incorrect Foundation Loads at Column-Brace Foundation Node due to Tolerance Issue
            • Nodal load moments not displayed in Ram Frame
          • +RAM SS - CONNECT Version 15.05 Issues
          • +RAM SS - CONNECT Version 15.11 Issues
          • +RAM SS - CONNECT Version 16.00 Issues
          • +RAM SS - CONNECT Version 17.00 Issues
          • +RAM SS - CONNECT Version 17.01 Issues
          • +RAM SS - CONNECT Version 17.02 Issues
          • +RAM SS - CONNECT Version 17.04 Issues
        • +Recordings from past RAM webinars
      • +STAAD.Pro
      • +STAAD Foundation Advanced
      • +STAAD Advanced Concrete Design (RCDC)
      • +STAAD.building
      • +STAAD RCDC FE
      • +Scenario Services
      • +STAAD.offshore
      • +Limcon
      • +Microstran
      • +MStower
      • +Structural Dashboard
      • +Structural WorkSuite
    • +RAM | STAAD Learning Resources
    • Simplifications to Bentley's Engineering Simulation Software Licenses

     
     Questions about this article, topic, or product? Click here. 

    EC2 Concrete Column Design Reported VEd Forces

    Reported Major and Minor Shear Values RAM Concrete Column  Product(s): RAM Concrete Column
      First Affected Version:
    Found in Version: 15.04.00.00
    Fixed in Version 15.05.00.00
      Environment: N/A
      Area: Report
      Subarea: N/A
      Defect Number: 658764

    Problem Description

    When EC2 is selected as the design code, the critical major and minor shear forces (VEd) listed in the Design Report may not be the actual critical shear forces used in the design. This is a reporting issue only. The correct critical shear forces are used in the design and can be viewed in the View/Update dialog.

    Reason

    Only the first two load combinations are considered for the reported critical shear forces. When another load combination controls, the reporting error will occur.

    Solution

    Fixed in version 15.05.00.

    • reports
    • RAM Structural System
    • 15.05.00
    • known issue
    • Column Design
    • Ram Concrete
    • Share
    • History
    • More
    • Cancel
    • Karl G Created by Bentley Colleague Karl G
    • When: Fri, Jul 14 2017 1:31 PM
    • Revisions: 1
    • Comments: 0
    Recommended
    Related
    Communities
    • Home
    • Getting Started
    • Community Central
    • Products
    • Support
    • Secure File Upload
    • Feedback
    Support and Services
    • Home
    • Product Support
    • Downloads
    • Subscription Services Portal
    Training and Learning
    • Home
    • About Bentley Institute
    • My Learning History
    • Reference Books
    Social Media
    •    LinkedIn
    •    Facebook
    •    Twitter
    •    YouTube
    •    RSS Feed
    •    Email

    © 2023 Bentley Systems, Incorporated  |  Contact Us  |  Privacy |  Terms of Use  |  Cookies