<?xml version="1.0" encoding="UTF-8" ?>
<?xml-stylesheet type="text/xsl" href="https://communities.bentley.com/cfs-file/__key/system/syndication/rss.xsl" media="screen"?><rss version="2.0" xmlns:dc="http://purl.org/dc/elements/1.1/"><channel><title>Ram Connection Does Not Launch from Ram Manager</title><link>https://communities.bentley.com/products/ram-staad/w/structural_analysis_and_design__wiki/36228/ram-connection-does-not-launch-from-ram-manager</link><description /><dc:language>en-US</dc:language><generator>Telligent Community 12</generator><item><title>Ram Connection Does Not Launch from Ram Manager</title><link>https://communities.bentley.com/products/ram-staad/w/structural_analysis_and_design__wiki/36228/ram-connection-does-not-launch-from-ram-manager</link><pubDate>Mon, 28 Aug 2017 20:38:47 GMT</pubDate><guid isPermaLink="false">6dad98f5-dbc9-4c4d-a9ba-e9da8dc6aa8e:ff7cbe36-8359-4559-a5af-fdadc73e0ab4</guid><dc:creator>Seth Guthrie</dc:creator><comments>https://communities.bentley.com/products/ram-staad/w/structural_analysis_and_design__wiki/36228/ram-connection-does-not-launch-from-ram-manager#comments</comments><description>Current Revision posted to RAM | STAAD | ADINA Wiki by Seth Guthrie on 8/28/2017 8:38:47 PM&lt;br /&gt;
&lt;table style="background-color:#dce5f0;border:0px solid #dce5f0;width:500px;" align="left" border="0"&gt;
&lt;tbody&gt;
&lt;tr&gt;
&lt;td style="text-align:right;"&gt;&lt;b&gt;&amp;nbsp;&lt;/b&gt;&lt;/td&gt;
&lt;td style="text-align:left;"&gt;&lt;span style="text-decoration:underline;"&gt;&lt;strong&gt;Applies To&lt;span style="font-size:medium;"&gt;&amp;nbsp;&lt;/span&gt;&lt;/strong&gt;&lt;/span&gt;&lt;/td&gt;
&lt;td&gt;&lt;/td&gt;
&lt;td&gt;&lt;/td&gt;
&lt;/tr&gt;
&lt;tr&gt;
&lt;td style="text-align:right;"&gt;&lt;strong&gt;&amp;nbsp;&lt;/strong&gt;&lt;/td&gt;
&lt;td style="text-align:right;"&gt;&lt;strong&gt;Product:&lt;/strong&gt;&lt;/td&gt;
&lt;td&gt;RAM Connection&amp;nbsp;for RAM SS&lt;/td&gt;
&lt;td&gt;&lt;/td&gt;
&lt;/tr&gt;
&lt;tr&gt;
&lt;td style="text-align:right;"&gt;&lt;strong&gt;&lt;/strong&gt;&lt;/td&gt;
&lt;td style="margin-left:30px;text-align:right;"&gt;&lt;strong&gt;First Affected Version:&lt;/strong&gt;&lt;/td&gt;
&lt;td&gt;11.01.01.240 (15.05.00)&lt;/td&gt;
&lt;td&gt;&lt;/td&gt;
&lt;/tr&gt;
&lt;tr&gt;
&lt;td style="text-align:right;"&gt;&lt;/td&gt;
&lt;td style="text-align:right;"&gt;&lt;strong&gt;Found in Version:&lt;/strong&gt;&lt;/td&gt;
&lt;td&gt;11.01.01.240 (15.05.00)&lt;/td&gt;
&lt;td&gt;&lt;/td&gt;
&lt;/tr&gt;
&lt;tr&gt;
&lt;td style="text-align:right;"&gt;&lt;strong&gt;&amp;nbsp;&lt;/strong&gt;&lt;/td&gt;
&lt;td style="text-align:right;"&gt;&lt;strong&gt;Fixed in Version:&lt;/strong&gt;&lt;/td&gt;
&lt;td&gt;11.01.01.240 (* posted&amp;nbsp;8/24/17)&lt;/td&gt;
&lt;td&gt;&lt;/td&gt;
&lt;/tr&gt;
&lt;tr&gt;
&lt;td style="text-align:right;"&gt;&lt;strong&gt;&lt;/strong&gt;&lt;/td&gt;
&lt;td style="margin-left:30px;text-align:right;"&gt;&lt;strong&gt;Environment:&lt;/strong&gt;&lt;/td&gt;
&lt;td&gt;x32 and x64&lt;/td&gt;
&lt;td&gt;&lt;/td&gt;
&lt;/tr&gt;
&lt;tr&gt;
&lt;td style="text-align:right;"&gt;&lt;strong&gt;&amp;nbsp;&lt;/strong&gt;&lt;/td&gt;
&lt;td style="text-align:right;"&gt;&lt;strong&gt;Area:&amp;nbsp;&lt;/strong&gt;&lt;/td&gt;
&lt;td&gt;Import/Export&lt;/td&gt;
&lt;td&gt;&lt;/td&gt;
&lt;/tr&gt;
&lt;tr&gt;
&lt;td style="text-align:right;"&gt;&lt;strong&gt;&amp;nbsp;&lt;/strong&gt;&lt;/td&gt;
&lt;td style="margin-left:30px;text-align:right;"&gt;&lt;strong&gt;Issue Number:&amp;nbsp;&lt;/strong&gt;&lt;/td&gt;
&lt;td&gt;742806&lt;/td&gt;
&lt;td&gt;&lt;/td&gt;
&lt;/tr&gt;
&lt;/tbody&gt;
&lt;/table&gt;
&lt;h1&gt;Problem Description&lt;/h1&gt;
&lt;p&gt;If RAM Connection CONNECT Edition version 11.01.01.240 (x32) is installed, it cannot be launched from Ram Structural System CONNECT Edition (x64) via the Ram Manager menu or button.&amp;nbsp;&lt;/p&gt;
&lt;h1&gt;Reason&lt;/h1&gt;
&lt;p&gt;A defect in the installation corrected with a quick update.&lt;/p&gt;
&lt;h1&gt;Solution&lt;/h1&gt;
&lt;p&gt;An updated installation was posted to Software Downloads on August 24, 2017 that now works with Ram Structural System 15.05. &amp;nbsp;If the defective build from the prior week is installed it must be uninstalled before the new one can be installed.&amp;nbsp;&lt;/p&gt;
&lt;p&gt;&lt;b&gt;&lt;img alt=" " height="60" src="/cfs-file.ashx/__key/communityserver-components-sitefiles/TSG-Logo.png" width="189" /&gt;&lt;/b&gt;&lt;/p&gt;&lt;div style="clear:both;"&gt;&lt;/div&gt;

&lt;div style="font-size: 90%;"&gt;Tags: Active, Import/Export, 11.01.01, RAM Structural System, RAM Connection, known issue, defect, First 11.01.01&lt;/div&gt;
</description></item><item><title>Ram Connection Does Not Launch from Ram Manager</title><link>https://communities.bentley.com/products/ram-staad/w/structural_analysis_and_design__wiki/36228/ram-connection-does-not-launch-from-ram-manager/revision/5</link><pubDate>Mon, 28 Aug 2017 20:17:44 GMT</pubDate><guid isPermaLink="false">6dad98f5-dbc9-4c4d-a9ba-e9da8dc6aa8e:ff7cbe36-8359-4559-a5af-fdadc73e0ab4</guid><dc:creator>Seth Guthrie</dc:creator><comments>https://communities.bentley.com/products/ram-staad/w/structural_analysis_and_design__wiki/36228/ram-connection-does-not-launch-from-ram-manager#comments</comments><description>Revision 5 posted to RAM | STAAD | ADINA Wiki by Seth Guthrie on 8/28/2017 8:17:44 PM&lt;br /&gt;
&lt;table style="background-color:#dce5f0;border:0px solid #dce5f0;width:500px;" align="left" border="0"&gt;
&lt;tbody&gt;
&lt;tr&gt;
&lt;td style="text-align:right;"&gt;&lt;b&gt;&amp;nbsp;&lt;/b&gt;&lt;/td&gt;
&lt;td style="text-align:left;"&gt;&lt;span style="text-decoration:underline;"&gt;&lt;strong&gt;Applies To&lt;span style="font-size:medium;"&gt;&amp;nbsp;&lt;/span&gt;&lt;/strong&gt;&lt;/span&gt;&lt;/td&gt;
&lt;td&gt;&lt;/td&gt;
&lt;td&gt;&lt;/td&gt;
&lt;/tr&gt;
&lt;tr&gt;
&lt;td style="text-align:right;"&gt;&lt;strong&gt;&amp;nbsp;&lt;/strong&gt;&lt;/td&gt;
&lt;td style="text-align:right;"&gt;&lt;strong&gt;Product:&lt;/strong&gt;&lt;/td&gt;
&lt;td&gt;RAM Connection&amp;nbsp;for RAM SS&lt;/td&gt;
&lt;td&gt;&lt;/td&gt;
&lt;/tr&gt;
&lt;tr&gt;
&lt;td style="text-align:right;"&gt;&lt;strong&gt;&lt;/strong&gt;&lt;/td&gt;
&lt;td style="margin-left:30px;text-align:right;"&gt;&lt;strong&gt;First Affected Version:&lt;/strong&gt;&lt;/td&gt;
&lt;td&gt;11.01.01.240 (15.05.00)&lt;/td&gt;
&lt;td&gt;&lt;/td&gt;
&lt;/tr&gt;
&lt;tr&gt;
&lt;td style="text-align:right;"&gt;&lt;/td&gt;
&lt;td style="text-align:right;"&gt;&lt;strong&gt;Found in Version:&lt;/strong&gt;&lt;/td&gt;
&lt;td&gt;11.01.01.240 (15.05.00)&lt;/td&gt;
&lt;td&gt;&lt;/td&gt;
&lt;/tr&gt;
&lt;tr&gt;
&lt;td style="text-align:right;"&gt;&lt;strong&gt;&amp;nbsp;&lt;/strong&gt;&lt;/td&gt;
&lt;td style="text-align:right;"&gt;&lt;strong&gt;Fixed in Version:&lt;/strong&gt;&lt;/td&gt;
&lt;td&gt;11.01.01.240 (* posted&amp;nbsp;8/24/17)&lt;/td&gt;
&lt;td&gt;&lt;/td&gt;
&lt;/tr&gt;
&lt;tr&gt;
&lt;td style="text-align:right;"&gt;&lt;strong&gt;&lt;/strong&gt;&lt;/td&gt;
&lt;td style="margin-left:30px;text-align:right;"&gt;&lt;strong&gt;Environment:&lt;/strong&gt;&lt;/td&gt;
&lt;td&gt;x32 and x64&lt;/td&gt;
&lt;td&gt;&lt;/td&gt;
&lt;/tr&gt;
&lt;tr&gt;
&lt;td style="text-align:right;"&gt;&lt;strong&gt;&amp;nbsp;&lt;/strong&gt;&lt;/td&gt;
&lt;td style="text-align:right;"&gt;&lt;strong&gt;Area:&amp;nbsp;&lt;/strong&gt;&lt;/td&gt;
&lt;td&gt;Import/Export&lt;/td&gt;
&lt;td&gt;&lt;/td&gt;
&lt;/tr&gt;
&lt;tr&gt;
&lt;td style="text-align:right;"&gt;&lt;strong&gt;&amp;nbsp;&lt;/strong&gt;&lt;/td&gt;
&lt;td style="margin-left:30px;text-align:right;"&gt;&lt;strong&gt;Issue Number:&amp;nbsp;&lt;/strong&gt;&lt;/td&gt;
&lt;td&gt;742806&lt;/td&gt;
&lt;td&gt;&lt;/td&gt;
&lt;/tr&gt;
&lt;/tbody&gt;
&lt;/table&gt;
&lt;h1&gt;Problem Description&lt;/h1&gt;
&lt;p&gt;If RAM Connection CONNECT Edition version 11.01.01.240 (x32) is installed, it cannot be launched from Ram Structural System CONNECT Edition (x64) via the Ram Manager menu or button.&amp;nbsp;&lt;/p&gt;
&lt;h1&gt;Reason&lt;/h1&gt;
&lt;p&gt;A new defect to be corrected in the next build.&lt;/p&gt;
&lt;h1&gt;Solution&lt;/h1&gt;
&lt;p&gt;An updated installation was posted to Software Downloads on August 24, 2017 that now works with Ram Structural System 15.05. &amp;nbsp;If the defective build from the prior week is installed it must be uninstalled before the new one can be installed.&amp;nbsp;&lt;/p&gt;
&lt;p&gt;&lt;b&gt;&lt;img alt=" " height="60" src="/cfs-file.ashx/__key/communityserver-components-sitefiles/TSG-Logo.png" width="189" /&gt;&lt;/b&gt;&lt;/p&gt;&lt;div style="clear:both;"&gt;&lt;/div&gt;

&lt;div style="font-size: 90%;"&gt;Tags: Active, Import/Export, 11.01.01, RAM Structural System, RAM Connection, known issue, defect, First 11.01.01&lt;/div&gt;
</description></item><item><title>Ram Connection Does Not Launch from Ram Manager</title><link>https://communities.bentley.com/products/ram-staad/w/structural_analysis_and_design__wiki/36228/ram-connection-does-not-launch-from-ram-manager/revision/4</link><pubDate>Tue, 22 Aug 2017 19:23:44 GMT</pubDate><guid isPermaLink="false">6dad98f5-dbc9-4c4d-a9ba-e9da8dc6aa8e:ff7cbe36-8359-4559-a5af-fdadc73e0ab4</guid><dc:creator>Karl G</dc:creator><comments>https://communities.bentley.com/products/ram-staad/w/structural_analysis_and_design__wiki/36228/ram-connection-does-not-launch-from-ram-manager#comments</comments><description>Revision 4 posted to RAM | STAAD | ADINA Wiki by Karl G on 8/22/2017 7:23:44 PM&lt;br /&gt;
&lt;table style="background-color:#dce5f0;border:0px solid #dce5f0;width:500px;" align="left" border="0"&gt;
&lt;tbody&gt;
&lt;tr&gt;
&lt;td style="text-align:right;"&gt;&lt;b&gt;&amp;nbsp;&lt;/b&gt;&lt;/td&gt;
&lt;td style="text-align:left;"&gt;&lt;span style="text-decoration:underline;"&gt;&lt;strong&gt;Applies To&lt;span style="font-size:medium;"&gt;&amp;nbsp;&lt;/span&gt;&lt;/strong&gt;&lt;/span&gt;&lt;/td&gt;
&lt;td&gt;&lt;/td&gt;
&lt;td&gt;&lt;/td&gt;
&lt;/tr&gt;
&lt;tr&gt;
&lt;td style="text-align:right;"&gt;&lt;strong&gt;&amp;nbsp;&lt;/strong&gt;&lt;/td&gt;
&lt;td style="text-align:right;"&gt;&lt;strong&gt;Product:&lt;/strong&gt;&lt;/td&gt;
&lt;td&gt;RAM Connection&amp;nbsp;for RAM SS&lt;/td&gt;
&lt;td&gt;&lt;/td&gt;
&lt;/tr&gt;
&lt;tr&gt;
&lt;td style="text-align:right;"&gt;&lt;strong&gt;&lt;/strong&gt;&lt;/td&gt;
&lt;td style="margin-left:30px;text-align:right;"&gt;&lt;strong&gt;First Affected Version:&lt;/strong&gt;&lt;/td&gt;
&lt;td&gt;11.01.01.240 (15.05.00)&lt;/td&gt;
&lt;td&gt;&lt;/td&gt;
&lt;/tr&gt;
&lt;tr&gt;
&lt;td style="text-align:right;"&gt;&lt;/td&gt;
&lt;td style="text-align:right;"&gt;&lt;strong&gt;Found in Version:&lt;/strong&gt;&lt;/td&gt;
&lt;td&gt;11.01.01.240 (15.05.00)&lt;/td&gt;
&lt;td&gt;&lt;/td&gt;
&lt;/tr&gt;
&lt;tr&gt;
&lt;td style="text-align:right;"&gt;&lt;strong&gt;&amp;nbsp;&lt;/strong&gt;&lt;/td&gt;
&lt;td style="text-align:right;"&gt;&lt;strong&gt;Fixed in Version:&lt;/strong&gt;&lt;/td&gt;
&lt;td&gt;&lt;/td&gt;
&lt;td&gt;&lt;/td&gt;
&lt;/tr&gt;
&lt;tr&gt;
&lt;td style="text-align:right;"&gt;&lt;strong&gt;&lt;/strong&gt;&lt;/td&gt;
&lt;td style="margin-left:30px;text-align:right;"&gt;&lt;strong&gt;Environment:&lt;/strong&gt;&lt;/td&gt;
&lt;td&gt;x32 and x64&lt;/td&gt;
&lt;td&gt;&lt;/td&gt;
&lt;/tr&gt;
&lt;tr&gt;
&lt;td style="text-align:right;"&gt;&lt;strong&gt;&amp;nbsp;&lt;/strong&gt;&lt;/td&gt;
&lt;td style="text-align:right;"&gt;&lt;strong&gt;Area:&amp;nbsp;&lt;/strong&gt;&lt;/td&gt;
&lt;td&gt;Import/Export&lt;/td&gt;
&lt;td&gt;&lt;/td&gt;
&lt;/tr&gt;
&lt;tr&gt;
&lt;td style="text-align:right;"&gt;&lt;strong&gt;&amp;nbsp;&lt;/strong&gt;&lt;/td&gt;
&lt;td style="margin-left:30px;text-align:right;"&gt;&lt;strong&gt;Issue Number:&amp;nbsp;&lt;/strong&gt;&lt;/td&gt;
&lt;td&gt;742806&lt;/td&gt;
&lt;td&gt;&lt;/td&gt;
&lt;/tr&gt;
&lt;/tbody&gt;
&lt;/table&gt;
&lt;h1&gt;Problem Description&lt;/h1&gt;
&lt;p&gt;If RAM Connection CONNECT Edition version 11.01.01.240 (x32) is installed, it cannot be launched from Ram Structural System CONNECT Edition (x64) via the Ram Manager menu or button.&amp;nbsp;&lt;/p&gt;
&lt;h1&gt;Reason&lt;/h1&gt;
&lt;p&gt;A new defect to be corrected in the next build.&lt;/p&gt;
&lt;h1&gt;Solution&lt;/h1&gt;
&lt;p&gt;Problem to be corrected in the next build after 11.01.01.240. &amp;nbsp;Until then, if integration with Ram Structural System is required, uninstall Ram Connection 11.01.011.240 and reinstall an older version (e.g. 11.01.00.227).&amp;nbsp;&lt;/p&gt;
&lt;p&gt;When uninstalling and reverting back to the previous version, please follow the instructions under the RAM Connection on the web page below to perform a clean install of the program.&lt;/p&gt;
&lt;p&gt;&lt;a title="Performing a Clean Installation" href="/products/ram-staad/w/structural_analysis_and_design__wiki/3336/performing-a-clean-installation-tn"&gt;Performing a Clean Installation&lt;/a&gt;&lt;/p&gt;
&lt;p&gt;&lt;b&gt;&lt;img alt=" " height="60" src="/cfs-file.ashx/__key/communityserver-components-sitefiles/TSG-Logo.png" width="189" /&gt;&lt;/b&gt;&lt;/p&gt;&lt;div style="clear:both;"&gt;&lt;/div&gt;

&lt;div style="font-size: 90%;"&gt;Tags: Active, Import/Export, RAM Structural System, RAM Connection, known issue, defect, First 11.01.01&lt;/div&gt;
</description></item><item><title>Ram Connection Does Not Launch from Ram Manager</title><link>https://communities.bentley.com/products/ram-staad/w/structural_analysis_and_design__wiki/36228/ram-connection-does-not-launch-from-ram-manager/revision/3</link><pubDate>Tue, 22 Aug 2017 17:11:42 GMT</pubDate><guid isPermaLink="false">6dad98f5-dbc9-4c4d-a9ba-e9da8dc6aa8e:ff7cbe36-8359-4559-a5af-fdadc73e0ab4</guid><dc:creator>Seth Guthrie</dc:creator><comments>https://communities.bentley.com/products/ram-staad/w/structural_analysis_and_design__wiki/36228/ram-connection-does-not-launch-from-ram-manager#comments</comments><description>Revision 3 posted to RAM | STAAD | ADINA Wiki by Seth Guthrie on 8/22/2017 5:11:42 PM&lt;br /&gt;
&lt;table style="background-color:#dce5f0;border:0px solid #dce5f0;width:500px;" align="left" border="0"&gt;
&lt;tbody&gt;
&lt;tr&gt;
&lt;td style="text-align:right;"&gt;&lt;b&gt;&amp;nbsp;&lt;/b&gt;&lt;/td&gt;
&lt;td style="text-align:left;"&gt;&lt;span style="text-decoration:underline;"&gt;&lt;strong&gt;Applies To&lt;span style="font-size:medium;"&gt;&amp;nbsp;&lt;/span&gt;&lt;/strong&gt;&lt;/span&gt;&lt;/td&gt;
&lt;td&gt;&lt;/td&gt;
&lt;td&gt;&lt;/td&gt;
&lt;/tr&gt;
&lt;tr&gt;
&lt;td style="text-align:right;"&gt;&lt;strong&gt;&amp;nbsp;&lt;/strong&gt;&lt;/td&gt;
&lt;td style="text-align:right;"&gt;&lt;strong&gt;Product:&lt;/strong&gt;&lt;/td&gt;
&lt;td&gt;RAM Connection&amp;nbsp;for RAM SS&lt;/td&gt;
&lt;td&gt;&lt;/td&gt;
&lt;/tr&gt;
&lt;tr&gt;
&lt;td style="text-align:right;"&gt;&lt;strong&gt;&lt;/strong&gt;&lt;/td&gt;
&lt;td style="margin-left:30px;text-align:right;"&gt;&lt;strong&gt;First Affected Version:&lt;/strong&gt;&lt;/td&gt;
&lt;td&gt;11.01.01.240 (15.05.00)&lt;/td&gt;
&lt;td&gt;&lt;/td&gt;
&lt;/tr&gt;
&lt;tr&gt;
&lt;td style="text-align:right;"&gt;&lt;/td&gt;
&lt;td style="text-align:right;"&gt;&lt;strong&gt;Found in Version:&lt;/strong&gt;&lt;/td&gt;
&lt;td&gt;11.01.01.240 (15.05.00)&lt;/td&gt;
&lt;td&gt;&lt;/td&gt;
&lt;/tr&gt;
&lt;tr&gt;
&lt;td style="text-align:right;"&gt;&lt;strong&gt;&amp;nbsp;&lt;/strong&gt;&lt;/td&gt;
&lt;td style="text-align:right;"&gt;&lt;strong&gt;Fixed in Version:&lt;/strong&gt;&lt;/td&gt;
&lt;td&gt;&lt;/td&gt;
&lt;td&gt;&lt;/td&gt;
&lt;/tr&gt;
&lt;tr&gt;
&lt;td style="text-align:right;"&gt;&lt;strong&gt;&lt;/strong&gt;&lt;/td&gt;
&lt;td style="margin-left:30px;text-align:right;"&gt;&lt;strong&gt;Environment:&lt;/strong&gt;&lt;/td&gt;
&lt;td&gt;x32 and x64&lt;/td&gt;
&lt;td&gt;&lt;/td&gt;
&lt;/tr&gt;
&lt;tr&gt;
&lt;td style="text-align:right;"&gt;&lt;strong&gt;&amp;nbsp;&lt;/strong&gt;&lt;/td&gt;
&lt;td style="text-align:right;"&gt;&lt;strong&gt;Area:&amp;nbsp;&lt;/strong&gt;&lt;/td&gt;
&lt;td&gt;Import/Export&lt;/td&gt;
&lt;td&gt;&lt;/td&gt;
&lt;/tr&gt;
&lt;tr&gt;
&lt;td style="text-align:right;"&gt;&lt;strong&gt;&amp;nbsp;&lt;/strong&gt;&lt;/td&gt;
&lt;td style="margin-left:30px;text-align:right;"&gt;&lt;strong&gt;Issue Number:&amp;nbsp;&lt;/strong&gt;&lt;/td&gt;
&lt;td&gt;742806&lt;/td&gt;
&lt;td&gt;&lt;/td&gt;
&lt;/tr&gt;
&lt;/tbody&gt;
&lt;/table&gt;
&lt;h1&gt;Problem Description&lt;/h1&gt;
&lt;p&gt;If RAM Connection CONNECT Edition version 11.01.01.240 (x32) is installed, it cannot be launched from Ram Structural System CONNECT Edition (x64) via the Ram Manager menu or button.&amp;nbsp;&lt;/p&gt;
&lt;h1&gt;Reason&lt;/h1&gt;
&lt;p&gt;A new defect to be corrected in the next build.&lt;/p&gt;
&lt;h1&gt;Solution&lt;/h1&gt;
&lt;p&gt;Problem to be corrected in the next build after 11.01.01.240. &amp;nbsp;Until then, if integration with Ram Structural System is required, uninstall Ram Connection 11.01.011.240 and reinstall an older version (e.g. 11.01.00.227).&amp;nbsp;&lt;/p&gt;
&lt;p&gt;&lt;b&gt;&lt;img alt=" " height="60" src="/cfs-file.ashx/__key/communityserver-components-sitefiles/TSG-Logo.png" width="189" /&gt;&lt;/b&gt;&lt;/p&gt;&lt;div style="clear:both;"&gt;&lt;/div&gt;

&lt;div style="font-size: 90%;"&gt;Tags: Active, Import/Export, RAM Structural System, RAM Connection, known issue, defect, First 11.01.01&lt;/div&gt;
</description></item><item><title>Ram Connection Does Not Launch from Ram Manager</title><link>https://communities.bentley.com/products/ram-staad/w/structural_analysis_and_design__wiki/36228/ram-connection-does-not-launch-from-ram-manager/revision/2</link><pubDate>Tue, 22 Aug 2017 17:04:16 GMT</pubDate><guid isPermaLink="false">6dad98f5-dbc9-4c4d-a9ba-e9da8dc6aa8e:ff7cbe36-8359-4559-a5af-fdadc73e0ab4</guid><dc:creator>Seth Guthrie</dc:creator><comments>https://communities.bentley.com/products/ram-staad/w/structural_analysis_and_design__wiki/36228/ram-connection-does-not-launch-from-ram-manager#comments</comments><description>Revision 2 posted to RAM | STAAD | ADINA Wiki by Seth Guthrie on 8/22/2017 5:04:16 PM&lt;br /&gt;
&lt;table style="background-color:#dce5f0;border:0px solid #dce5f0;width:500px;" align="left" border="0"&gt;
&lt;tbody&gt;
&lt;tr&gt;
&lt;td style="text-align:right;"&gt;&lt;b&gt;&amp;nbsp;&lt;/b&gt;&lt;/td&gt;
&lt;td style="text-align:left;"&gt;&lt;span style="text-decoration:underline;"&gt;&lt;strong&gt;Applies To&lt;span style="font-size:medium;"&gt;&amp;nbsp;&lt;/span&gt;&lt;/strong&gt;&lt;/span&gt;&lt;/td&gt;
&lt;td&gt;&lt;/td&gt;
&lt;td&gt;&lt;/td&gt;
&lt;/tr&gt;
&lt;tr&gt;
&lt;td style="text-align:right;"&gt;&lt;strong&gt;&amp;nbsp;&lt;/strong&gt;&lt;/td&gt;
&lt;td style="text-align:right;"&gt;&lt;strong&gt;Product:&lt;/strong&gt;&lt;/td&gt;
&lt;td&gt;RAM Connection&amp;nbsp;for RAM SS&lt;/td&gt;
&lt;td&gt;&lt;/td&gt;
&lt;/tr&gt;
&lt;tr&gt;
&lt;td style="text-align:right;"&gt;&lt;strong&gt;&lt;/strong&gt;&lt;/td&gt;
&lt;td style="margin-left:30px;text-align:right;"&gt;&lt;strong&gt;First Affected Version:&lt;/strong&gt;&lt;/td&gt;
&lt;td&gt;11.01.01.240 (15.05.00)&lt;/td&gt;
&lt;td&gt;&lt;/td&gt;
&lt;/tr&gt;
&lt;tr&gt;
&lt;td style="text-align:right;"&gt;&lt;/td&gt;
&lt;td style="text-align:right;"&gt;&lt;strong&gt;Found in Version:&lt;/strong&gt;&lt;/td&gt;
&lt;td&gt;11.01.01.240 (15.05.00)&lt;/td&gt;
&lt;td&gt;&lt;/td&gt;
&lt;/tr&gt;
&lt;tr&gt;
&lt;td style="text-align:right;"&gt;&lt;strong&gt;&amp;nbsp;&lt;/strong&gt;&lt;/td&gt;
&lt;td style="text-align:right;"&gt;&lt;strong&gt;Fixed in Version:&lt;/strong&gt;&lt;/td&gt;
&lt;td&gt;&lt;/td&gt;
&lt;td&gt;&lt;/td&gt;
&lt;/tr&gt;
&lt;tr&gt;
&lt;td style="text-align:right;"&gt;&lt;strong&gt;&lt;/strong&gt;&lt;/td&gt;
&lt;td style="margin-left:30px;text-align:right;"&gt;&lt;strong&gt;Environment:&lt;/strong&gt;&lt;/td&gt;
&lt;td&gt;x32 and x64&lt;/td&gt;
&lt;td&gt;&lt;/td&gt;
&lt;/tr&gt;
&lt;tr&gt;
&lt;td style="text-align:right;"&gt;&lt;strong&gt;&amp;nbsp;&lt;/strong&gt;&lt;/td&gt;
&lt;td style="text-align:right;"&gt;&lt;strong&gt;Area:&amp;nbsp;&lt;/strong&gt;&lt;/td&gt;
&lt;td&gt;Import/Export&lt;/td&gt;
&lt;td&gt;&lt;/td&gt;
&lt;/tr&gt;
&lt;tr&gt;
&lt;td style="text-align:right;"&gt;&lt;strong&gt;&amp;nbsp;&lt;/strong&gt;&lt;/td&gt;
&lt;td style="margin-left:30px;text-align:right;"&gt;&lt;strong&gt;Issue Number:&amp;nbsp;&lt;/strong&gt;&lt;/td&gt;
&lt;td&gt;742806&lt;/td&gt;
&lt;td&gt;&lt;/td&gt;
&lt;/tr&gt;
&lt;/tbody&gt;
&lt;/table&gt;
&lt;h1&gt;Problem Description&lt;/h1&gt;
&lt;p&gt;If RAM Connection CONNECT Edition version 11.01.01.240 (x32) is installed, it cannot be launched from Ram Structural System CONNECT Edition (x64) via the Ram Manager menu or button.&amp;nbsp;&lt;/p&gt;
&lt;h1&gt;Reason&lt;/h1&gt;
&lt;p&gt;A new defect to be corrected in the next build.&lt;/p&gt;
&lt;h1&gt;Solution&lt;/h1&gt;
&lt;p&gt;Problem to be corrected in the next build after 11.01.01.240. &amp;nbsp;Until then, if integration with Ram Structural System is required, uninstall Ram Connection 11.01.011.240 and reinstall an older version (e.g. 11.01.00.227).&amp;nbsp;&lt;/p&gt;
&lt;p&gt;&lt;b&gt;&lt;img alt=" " height="60" src="/cfs-file.ashx/__key/communityserver-components-sitefiles/TSG-Logo.png" width="189" /&gt;&lt;/b&gt;&lt;/p&gt;&lt;div style="clear:both;"&gt;&lt;/div&gt;

&lt;div style="font-size: 90%;"&gt;Tags: Import/Export, RAM Structural System, RAM Connection, known issue, defect, First 11.01.01&lt;/div&gt;
</description></item><item><title>Ram Connection Does Not Launch from Ram Manager</title><link>https://communities.bentley.com/products/ram-staad/w/structural_analysis_and_design__wiki/36228/ram-connection-does-not-launch-from-ram-manager/revision/1</link><pubDate>Tue, 22 Aug 2017 17:01:16 GMT</pubDate><guid isPermaLink="false">6dad98f5-dbc9-4c4d-a9ba-e9da8dc6aa8e:ff7cbe36-8359-4559-a5af-fdadc73e0ab4</guid><dc:creator>Seth Guthrie</dc:creator><comments>https://communities.bentley.com/products/ram-staad/w/structural_analysis_and_design__wiki/36228/ram-connection-does-not-launch-from-ram-manager#comments</comments><description>Revision 1 posted to RAM | STAAD | ADINA Wiki by Seth Guthrie on 8/22/2017 5:01:16 PM&lt;br /&gt;
&lt;table style="background-color:#dce5f0;border:0px solid #dce5f0;width:500px;" align="left" border="0"&gt;
&lt;tbody&gt;
&lt;tr&gt;
&lt;td style="text-align:right;"&gt;&lt;b&gt;&amp;nbsp;&lt;/b&gt;&lt;/td&gt;
&lt;td style="text-align:left;"&gt;&lt;span style="text-decoration:underline;"&gt;&lt;strong&gt;Applies To&lt;span style="font-size:medium;"&gt;&amp;nbsp;&lt;/span&gt;&lt;/strong&gt;&lt;/span&gt;&lt;/td&gt;
&lt;td&gt;&lt;/td&gt;
&lt;td&gt;&lt;/td&gt;
&lt;/tr&gt;
&lt;tr&gt;
&lt;td style="text-align:right;"&gt;&lt;strong&gt;&amp;nbsp;&lt;/strong&gt;&lt;/td&gt;
&lt;td style="text-align:right;"&gt;&lt;strong&gt;Product:&lt;/strong&gt;&lt;/td&gt;
&lt;td&gt;RAM Connection&amp;nbsp;for RAM SS&lt;/td&gt;
&lt;td&gt;&lt;/td&gt;
&lt;/tr&gt;
&lt;tr&gt;
&lt;td style="text-align:right;"&gt;&lt;strong&gt;&lt;/strong&gt;&lt;/td&gt;
&lt;td style="margin-left:30px;text-align:right;"&gt;&lt;strong&gt;First Affected Version:&lt;/strong&gt;&lt;/td&gt;
&lt;td&gt;11.01.01.240 (15.05.00)&lt;/td&gt;
&lt;td&gt;&lt;/td&gt;
&lt;/tr&gt;
&lt;tr&gt;
&lt;td style="text-align:right;"&gt;&lt;/td&gt;
&lt;td style="text-align:right;"&gt;&lt;strong&gt;Found in Version:&lt;/strong&gt;&lt;/td&gt;
&lt;td&gt;11.01.01.240 (15.05.00)&lt;/td&gt;
&lt;td&gt;&lt;/td&gt;
&lt;/tr&gt;
&lt;tr&gt;
&lt;td style="text-align:right;"&gt;&lt;strong&gt;&amp;nbsp;&lt;/strong&gt;&lt;/td&gt;
&lt;td style="text-align:right;"&gt;&lt;strong&gt;Fixed in Version:&lt;/strong&gt;&lt;/td&gt;
&lt;td&gt;&lt;/td&gt;
&lt;td&gt;&lt;/td&gt;
&lt;/tr&gt;
&lt;tr&gt;
&lt;td style="text-align:right;"&gt;&lt;strong&gt;&lt;/strong&gt;&lt;/td&gt;
&lt;td style="margin-left:30px;text-align:right;"&gt;&lt;strong&gt;Environment:&lt;/strong&gt;&lt;/td&gt;
&lt;td&gt;x32 and x64&lt;/td&gt;
&lt;td&gt;&lt;/td&gt;
&lt;/tr&gt;
&lt;tr&gt;
&lt;td style="text-align:right;"&gt;&lt;strong&gt;&amp;nbsp;&lt;/strong&gt;&lt;/td&gt;
&lt;td style="text-align:right;"&gt;&lt;strong&gt;Area:&amp;nbsp;&lt;/strong&gt;&lt;/td&gt;
&lt;td&gt;Import/Export&lt;/td&gt;
&lt;td&gt;&lt;/td&gt;
&lt;/tr&gt;
&lt;tr&gt;
&lt;td style="text-align:right;"&gt;&lt;strong&gt;&amp;nbsp;&lt;/strong&gt;&lt;/td&gt;
&lt;td style="margin-left:30px;text-align:right;"&gt;&lt;strong&gt;Issue Number:&amp;nbsp;&lt;/strong&gt;&lt;/td&gt;
&lt;td&gt;7&lt;/td&gt;
&lt;td&gt;&lt;/td&gt;
&lt;/tr&gt;
&lt;/tbody&gt;
&lt;/table&gt;
&lt;h1&gt;Problem Description&lt;/h1&gt;
&lt;p&gt;If RAM Connection CONNECT Edition version 11.01.01.240 (x32) is installed, it cannot be launched from Ram Structural System CONNECT Edition (x64) via the Ram Manager menu or button.&amp;nbsp;&lt;/p&gt;
&lt;h1&gt;Reason&lt;/h1&gt;
&lt;p&gt;A new defect to be corrected in the next build.&lt;/p&gt;
&lt;h1&gt;Solution&lt;/h1&gt;
&lt;p&gt;Problem to be corrected in the next build after 11.01.01.240. &amp;nbsp;Until then, if integration with Ram Structural System is required, uninstall Ram Connection 11.01.011.240 and reinstall an older version (e.g. 11.01.00.227).&amp;nbsp;&lt;/p&gt;
&lt;p&gt;&lt;b&gt;&lt;img alt=" " height="60" src="/cfs-file.ashx/__key/communityserver-components-sitefiles/TSG-Logo.png" width="189" /&gt;&lt;/b&gt;&lt;/p&gt;&lt;div style="clear:both;"&gt;&lt;/div&gt;

&lt;div style="font-size: 90%;"&gt;Tags: Import/Export, RAM Structural System, RAM Connection, known issue, defect, First 11.01.01&lt;/div&gt;