Seasonal Temperature loading


  
 Applies To 
  
 Product(s):STAAD.Pro
 Version(s):All
 Environment: N/A
 Area: Modeling Solutions
 Subarea: Loading
 Original Author:Bentley Technical Support Group
  

Given site condition Maximum seasonal temperature is 45 deg C and Minimum is 15 deg C.In staad pro, if we specify a temperature change for axial elongation input as 30, will this account for this condition. Or should we incorprate in addition an input value of -30.

Answer :

You have to know three temperatures :

1) the stress-free temperature, which is the temperature that the beam was at when it was constructed or installed. Call it A.

2) The temperature of the top fiber (the fiber that is farthest along the positive direction of the local Y axis). Call it B.

3) The temperature of the bottom fiber (the fiber that is farthest along the negative direction of the local Y axis). Call it C.


When you specify the temperature load, the command is


member-list TEMPERATURE f1 f2

where

f1 = (B+C)/2 - A