<?xml version="1.0" encoding="UTF-8" ?>
<?xml-stylesheet type="text/xsl" href="https://communities.bentley.com/cfs-file/__key/system/syndication/rss.xsl" media="screen"?><rss version="2.0" xmlns:dc="http://purl.org/dc/elements/1.1/"><channel><title>Existing custom steel section databases cannot be opened in the STAAD.Pro CONNECT Edition</title><link>https://communities.bentley.com/products/ram-staad/w/structural_analysis_and_design__wiki/38173/existing-custom-steel-section-databases-cannot-be-opened-in-the-staad-pro-connect-edition</link><description /><dc:language>en-US</dc:language><generator>Telligent Community 12</generator><item><title>Existing custom steel section databases cannot be opened in the STAAD.Pro CONNECT Edition</title><link>https://communities.bentley.com/products/ram-staad/w/structural_analysis_and_design__wiki/38173/existing-custom-steel-section-databases-cannot-be-opened-in-the-staad-pro-connect-edition</link><pubDate>Thu, 23 Feb 2023 10:54:46 GMT</pubDate><guid isPermaLink="false">6dad98f5-dbc9-4c4d-a9ba-e9da8dc6aa8e:7d37d914-2b9f-4d1c-ab4d-9e29524b1f0e</guid><dc:creator>Carlos Aguera</dc:creator><comments>https://communities.bentley.com/products/ram-staad/w/structural_analysis_and_design__wiki/38173/existing-custom-steel-section-databases-cannot-be-opened-in-the-staad-pro-connect-edition#comments</comments><description>Current Revision posted to RAM | STAAD | ADINA Wiki by Carlos Aguera on 2/23/2023 10:54:46 AM&lt;br /&gt;
&lt;table style="background-color:#dce5f0;border:0px solid #dce5f0;width:500px;" align="left" border="0"&gt;
&lt;tbody&gt;
&lt;tr&gt;
&lt;td style="text-align:right;"&gt;&lt;strong&gt;&amp;nbsp;&lt;/strong&gt;&lt;/td&gt;
&lt;td style="text-align:right;"&gt;&lt;strong&gt;Product:&lt;/strong&gt;&lt;/td&gt;
&lt;td&gt;STAAD.pro&lt;/td&gt;
&lt;td&gt;&lt;/td&gt;
&lt;/tr&gt;
&lt;tr&gt;
&lt;td style="text-align:right;"&gt;&lt;strong&gt;&lt;/strong&gt;&lt;/td&gt;
&lt;td style="text-align:right;"&gt;&lt;strong&gt;First Affected Version:&lt;/strong&gt;&lt;/td&gt;
&lt;td&gt;21.00.02.30&lt;/td&gt;
&lt;td&gt;&lt;/td&gt;
&lt;/tr&gt;
&lt;tr&gt;
&lt;td style="text-align:right;"&gt;&lt;strong&gt;&amp;nbsp;&lt;/strong&gt;&lt;/td&gt;
&lt;td style="text-align:right;"&gt;&lt;strong&gt;Found in Version:&lt;/strong&gt;&lt;/td&gt;
&lt;td&gt;21.00.02.30&lt;/td&gt;
&lt;td&gt;&lt;/td&gt;
&lt;/tr&gt;
&lt;tr&gt;
&lt;td style="text-align:right;"&gt;&lt;strong&gt;&lt;/strong&gt;&lt;/td&gt;
&lt;td style="text-align:right;"&gt;&lt;strong&gt;Fixed and Released in Version:&lt;/strong&gt;&lt;/td&gt;
&lt;td&gt;&lt;span style="color:#008000;"&gt;&lt;strong&gt;21.03.00.146&lt;/strong&gt;&lt;/span&gt;&lt;/td&gt;
&lt;td&gt;&lt;/td&gt;
&lt;/tr&gt;
&lt;tr&gt;
&lt;td style="text-align:right;"&gt;&lt;strong&gt;&amp;nbsp;&lt;/strong&gt;&lt;/td&gt;
&lt;td style="text-align:right;"&gt;&lt;strong&gt;Area:&amp;nbsp;&lt;/strong&gt;&lt;/td&gt;
&lt;td&gt;Custom Steel&amp;nbsp;Section Database&lt;/td&gt;
&lt;td&gt;&lt;/td&gt;
&lt;/tr&gt;
&lt;tr&gt;
&lt;td style="text-align:right;"&gt;&lt;strong&gt;&amp;nbsp;&lt;/strong&gt;&lt;/td&gt;
&lt;td style="text-align:right;"&gt;&lt;strong&gt;Issue #:&lt;/strong&gt;&lt;/td&gt;
&lt;td&gt;870111&lt;/td&gt;
&lt;td&gt;&lt;/td&gt;
&lt;/tr&gt;
&lt;/tbody&gt;
&lt;/table&gt;
&lt;h1&gt;Problem Description&lt;/h1&gt;
&lt;p&gt;Older custom steel section databases created by users do not show up within the Section Database for the STAAD.Pro Connect Edition.&lt;/p&gt;
&lt;p&gt;Details on how to convert older section database files (mdb) to the newer format (.db3)&amp;nbsp;can be found &lt;a href="/products/ram-staad/w/structural_analysis_and_design__wiki/38174/migrating-existing-custom-steel-section-databases-to-the-staad-pro-connect-edition"&gt;here&lt;/a&gt;&lt;/p&gt;
&lt;p&gt;&lt;span style="color:#ff0000;font-size:150%;"&gt;&lt;em&gt;&lt;strong&gt;&amp;nbsp;&lt;/strong&gt;&lt;/em&gt;&lt;/span&gt;&lt;/p&gt;
&lt;p&gt;.&lt;/p&gt;
&lt;p&gt;&lt;span style="font-size:200%;"&gt;&lt;strong&gt;Steps to Reproduce&lt;/strong&gt;&lt;/span&gt;&lt;/p&gt;
&lt;ol&gt;
&lt;li&gt;Copy the older section database file (let&amp;rsquo;s say &amp;ldquo;aiscsections_ml_SLS.db3&amp;rdquo;) into the Sections folder of the installation [C:\ProgramData\Bentley\Engineering\STAAD.Pro CONNECT Edition\Sections]&lt;/li&gt;
&lt;li&gt;Go to Specification &amp;gt; Section Database and the new database does not show up&lt;/li&gt;
&lt;/ol&gt;
&lt;h1&gt;Workaround&lt;/h1&gt;
&lt;ol&gt;
&lt;li&gt;Go to the user profile folder &amp;ldquo;C:\Users\&amp;lt;user profile name&amp;gt;\AppData\Local\Bentley\Engineering\STAAD.Pro CONNECT Edition\Default\Sections&amp;rdquo;&lt;/li&gt;
&lt;li&gt;Open the&amp;nbsp;&amp;ldquo;Custom.ini&amp;rdquo; using Notepad or Worpad&lt;/li&gt;
&lt;li&gt;Search for &amp;lsquo;[CustomDBFlags]&amp;rsquo;&lt;/li&gt;
&lt;li&gt;Under the above section, Set &amp;lsquo;1&amp;rsquo; against &amp;lsquo;AISCSections&amp;rsquo;&lt;/li&gt;
&lt;li&gt;Next, search for &amp;lsquo;[CustomDBNames]&amp;rsquo;&lt;/li&gt;
&lt;li&gt;Under this section, Set &amp;lsquo;aiscsections_ml_SLS&amp;rsquo; against &amp;lsquo;AISCSections&amp;rsquo;&lt;/li&gt;
&lt;li&gt;&amp;nbsp;&lt;img alt=" " src="/resized-image/__size/640x480/__key/communityserver-wikis-components-files/00-00-00-00-54/1440.1.jpg" /&gt;&lt;/li&gt;
&lt;li&gt;Now, copy the &amp;lsquo;aiscsections_ml_SLS.db3&amp;rsquo; database to &amp;lsquo;C:\ProgramData\Bentley\Engineering\STAAD.Pro CONNECT Edition\Sections&amp;rsquo;&lt;/li&gt;
&lt;li&gt;There are a couple of more copies of the &amp;ldquo;Custom.ini&amp;rdquo; file within the following folders.&lt;/li&gt;
&lt;li&gt;C:\Program Files\Bentley\Engineering\STAAD.Pro CONNECT Edition\STAAD\Sections&lt;/li&gt;
&lt;li&gt;C:\ProgramData\Bentley\Engineering\STAAD.Pro CONNECT Edition\Sections&lt;/li&gt;
&lt;li&gt;In case you do not see the same entries updated in those files, please go ahead and manually change the data as suggested in steps 3 to 6 in these files too.&lt;/li&gt;
&lt;li&gt;StaadPro should now pick up sections from the above user database.&lt;/li&gt;
&lt;/ol&gt;
&lt;p&gt;&lt;/p&gt;
&lt;p&gt;Note : You may not be able to launch the Section Database Manager from within the Specification ribbon menu after you make the change. However the user sections should be accessible&lt;/p&gt;
&lt;p&gt;&lt;strong&gt;&lt;span style="font-size:200%;"&gt;Solution&lt;/span&gt;&lt;/strong&gt;&lt;/p&gt;
&lt;p&gt;&lt;span style="color:#008000;"&gt;&lt;strong&gt;The problem has been addressed in the STAAD.Pro CONNECT Edition&amp;nbsp;version 21.03.00.146.&amp;nbsp;&lt;/strong&gt;&lt;/span&gt;&lt;/p&gt;
&lt;p&gt;&lt;/p&gt;
&lt;p&gt;&lt;b&gt;&lt;img alt=" " height="60" src="/cfs-file.ashx/__key/communityserver-components-sitefiles/TSG-Logo.png" width="189" /&gt;&lt;/b&gt;&lt;/p&gt;&lt;div style="clear:both;"&gt;&lt;/div&gt;

&lt;div style="font-size: 90%;"&gt;Tags: custom section database, section database, known issue, db3, user section, Database, 21.00.02.30&lt;/div&gt;
</description></item><item><title>Existing custom steel section databases cannot be opened in the STAAD.Pro CONNECT Edition</title><link>https://communities.bentley.com/products/ram-staad/w/structural_analysis_and_design__wiki/38173/existing-custom-steel-section-databases-cannot-be-opened-in-the-staad-pro-connect-edition/revision/6</link><pubDate>Mon, 20 May 2019 22:07:05 GMT</pubDate><guid isPermaLink="false">6dad98f5-dbc9-4c4d-a9ba-e9da8dc6aa8e:7d37d914-2b9f-4d1c-ab4d-9e29524b1f0e</guid><dc:creator>Sye</dc:creator><comments>https://communities.bentley.com/products/ram-staad/w/structural_analysis_and_design__wiki/38173/existing-custom-steel-section-databases-cannot-be-opened-in-the-staad-pro-connect-edition#comments</comments><description>Revision 6 posted to RAM | STAAD | ADINA Wiki by Sye on 5/20/2019 10:07:05 PM&lt;br /&gt;
&lt;table style="background-color:#dce5f0;border:0px solid #dce5f0;width:500px;" align="left" border="0"&gt;
&lt;tbody&gt;
&lt;tr&gt;
&lt;td style="text-align:right;"&gt;&lt;strong&gt;&amp;nbsp;&lt;/strong&gt;&lt;/td&gt;
&lt;td style="text-align:right;"&gt;&lt;strong&gt;Product:&lt;/strong&gt;&lt;/td&gt;
&lt;td&gt;STAAD.pro&lt;/td&gt;
&lt;td&gt;&lt;/td&gt;
&lt;/tr&gt;
&lt;tr&gt;
&lt;td style="text-align:right;"&gt;&lt;strong&gt;&lt;/strong&gt;&lt;/td&gt;
&lt;td style="text-align:right;"&gt;&lt;strong&gt;First Affected Version:&lt;/strong&gt;&lt;/td&gt;
&lt;td&gt;21.00.02.30&lt;/td&gt;
&lt;td&gt;&lt;/td&gt;
&lt;/tr&gt;
&lt;tr&gt;
&lt;td style="text-align:right;"&gt;&lt;strong&gt;&amp;nbsp;&lt;/strong&gt;&lt;/td&gt;
&lt;td style="text-align:right;"&gt;&lt;strong&gt;Found in Version:&lt;/strong&gt;&lt;/td&gt;
&lt;td&gt;21.00.02.30&lt;/td&gt;
&lt;td&gt;&lt;/td&gt;
&lt;/tr&gt;
&lt;tr&gt;
&lt;td style="text-align:right;"&gt;&lt;strong&gt;&lt;/strong&gt;&lt;/td&gt;
&lt;td style="text-align:right;"&gt;&lt;strong&gt;Fixed and Released in Version:&lt;/strong&gt;&lt;/td&gt;
&lt;td&gt;&lt;span style="color:#008000;"&gt;&lt;strong&gt;21.03.00.146&lt;/strong&gt;&lt;/span&gt;&lt;/td&gt;
&lt;td&gt;&lt;/td&gt;
&lt;/tr&gt;
&lt;tr&gt;
&lt;td style="text-align:right;"&gt;&lt;strong&gt;&amp;nbsp;&lt;/strong&gt;&lt;/td&gt;
&lt;td style="text-align:right;"&gt;&lt;strong&gt;Area:&amp;nbsp;&lt;/strong&gt;&lt;/td&gt;
&lt;td&gt;Custom Steel&amp;nbsp;Section Database&lt;/td&gt;
&lt;td&gt;&lt;/td&gt;
&lt;/tr&gt;
&lt;tr&gt;
&lt;td style="text-align:right;"&gt;&lt;strong&gt;&amp;nbsp;&lt;/strong&gt;&lt;/td&gt;
&lt;td style="text-align:right;"&gt;&lt;strong&gt;Issue #:&lt;/strong&gt;&lt;/td&gt;
&lt;td&gt;870111&lt;/td&gt;
&lt;td&gt;&lt;/td&gt;
&lt;/tr&gt;
&lt;/tbody&gt;
&lt;/table&gt;
&lt;h1&gt;Problem Description&lt;/h1&gt;
&lt;p&gt;Older custom steel section databases created by users do not show up within the Section Database for the STAAD.Pro Connect Edition.&lt;/p&gt;
&lt;p&gt;Details on how to convert older section database files (mdb) to the newer format (.db3)&amp;nbsp;can be found &lt;a href="/products/ram-staad/w/structural_analysis_and_design__wiki/38174/migrating-existing-custom-steel-section-databases-to-the-staad-pro-connect-edition"&gt;here&lt;/a&gt;&lt;/p&gt;
&lt;p&gt;&lt;span style="color:#ff0000;font-size:150%;"&gt;&lt;em&gt;&lt;strong&gt;&amp;nbsp;&lt;/strong&gt;&lt;/em&gt;&lt;/span&gt;&lt;/p&gt;
&lt;p&gt;.&lt;/p&gt;
&lt;p&gt;&lt;span style="font-size:200%;"&gt;&lt;strong&gt;Steps to Reproduce&lt;/strong&gt;&lt;/span&gt;&lt;/p&gt;
&lt;ol&gt;
&lt;li&gt;Copy the older section database file (let&amp;rsquo;s say &amp;ldquo;aiscsections_ml_SLS.db3&amp;rdquo;) into the Sections folder of the installation [C:\ProgramData\Bentley\Engineering\STAAD.Pro CONNECT Edition\Sections]&lt;/li&gt;
&lt;li&gt;Go to Specification &amp;gt; Section Database and the new database does not show up&lt;/li&gt;
&lt;/ol&gt;
&lt;h1&gt;Workaround&lt;/h1&gt;
&lt;ol&gt;
&lt;li&gt;Go to the user profile folder &amp;ldquo;C:\Users\&amp;lt;user profile name&amp;gt;\AppData\Local\Bentley\Engineering\STAAD.Pro CONNECT Edition\Default\Sections&amp;rdquo;&lt;/li&gt;
&lt;li&gt;Open the&amp;nbsp;&amp;ldquo;Custom.ini&amp;rdquo; using Notepad or Worpad&lt;/li&gt;
&lt;li&gt;Search for &amp;lsquo;[CustomDBFlags]&amp;rsquo;&lt;/li&gt;
&lt;li&gt;Under the above section, Set &amp;lsquo;1&amp;rsquo; against &amp;lsquo;AISCSections&amp;rsquo;&lt;/li&gt;
&lt;li&gt;Next, search for &amp;lsquo;[CustomDBNames]&amp;rsquo;&lt;/li&gt;
&lt;li&gt;Under this section, Set &amp;lsquo;aiscsections_ml_SLS&amp;rsquo; against &amp;lsquo;AISCSections&amp;rsquo;&lt;/li&gt;
&lt;li&gt;&amp;nbsp;&lt;img alt=" " src="/resized-image/__size/640x480/__key/communityserver-wikis-components-files/00-00-00-00-54/1440.1.jpg" /&gt;&lt;/li&gt;
&lt;li&gt;Now, copy the &amp;lsquo;aiscsections_ml_SLS.db3&amp;rsquo; database to &amp;lsquo;C:\ProgramData\Bentley\Engineering\STAAD.Pro CONNECT Edition\Sections&amp;rsquo;&lt;/li&gt;
&lt;li&gt;There are a couple of more copies of the &amp;ldquo;Custom.ini&amp;rdquo; file within the following folders.&lt;/li&gt;
&lt;li&gt;C:\Program Files\Bentley\Engineering\STAAD.Pro CONNECT Edition\STAAD\Sections&lt;/li&gt;
&lt;li&gt;C:\ProgramData\Bentley\Engineering\STAAD.Pro CONNECT Edition\Sections&lt;/li&gt;
&lt;li&gt;In case you do not see the same entries updated in those files, please go ahead and manually change the data as suggested in steps 3 to 6 in these files too.&lt;/li&gt;
&lt;li&gt;StaadPro should now pick up sections from the above user database.&lt;/li&gt;
&lt;/ol&gt;
&lt;p&gt;&lt;/p&gt;
&lt;p&gt;Note : You may not be able to launch the Section Database Manager from within the Specification ribbon menu after you make the change. However the user sections should be accessible&lt;/p&gt;
&lt;p&gt;&lt;strong&gt;&lt;span style="font-size:200%;"&gt;Solution&lt;/span&gt;&lt;/strong&gt;&lt;/p&gt;
&lt;p&gt;&lt;span style="color:#008000;"&gt;&lt;strong&gt;The problem has been addressed in the STAAD.Pro CONNECT Edition&amp;nbsp;version 21.03.00.146.&amp;nbsp;&lt;/strong&gt;&lt;/span&gt;&lt;/p&gt;
&lt;p&gt;&lt;/p&gt;
&lt;p&gt;&lt;b&gt;&lt;img alt=" " height="60" src="/cfs-file.ashx/__key/communityserver-components-sitefiles/TSG-Logo.png" width="189" /&gt;&lt;/b&gt;&lt;/p&gt;&lt;div style="clear:both;"&gt;&lt;/div&gt;

&lt;div style="font-size: 90%;"&gt;Tags: custom section database, section database, known issue, db3, user section, Database, 21.00.02.30&lt;/div&gt;
</description></item><item><title>Existing custom steel section databases cannot be opened in the STAAD.Pro Connect Edition</title><link>https://communities.bentley.com/products/ram-staad/w/structural_analysis_and_design__wiki/38173/existing-custom-steel-section-databases-cannot-be-opened-in-the-staad-pro-connect-edition/revision/5</link><pubDate>Mon, 20 May 2019 22:06:29 GMT</pubDate><guid isPermaLink="false">6dad98f5-dbc9-4c4d-a9ba-e9da8dc6aa8e:7d37d914-2b9f-4d1c-ab4d-9e29524b1f0e</guid><dc:creator>Sye</dc:creator><comments>https://communities.bentley.com/products/ram-staad/w/structural_analysis_and_design__wiki/38173/existing-custom-steel-section-databases-cannot-be-opened-in-the-staad-pro-connect-edition#comments</comments><description>Revision 5 posted to RAM | STAAD | ADINA Wiki by Sye on 5/20/2019 10:06:29 PM&lt;br /&gt;
&lt;table style="background-color:#dce5f0;border:0px solid #dce5f0;width:500px;" align="left" border="0"&gt;
&lt;tbody&gt;
&lt;tr&gt;
&lt;td style="text-align:right;"&gt;&lt;strong&gt;&amp;nbsp;&lt;/strong&gt;&lt;/td&gt;
&lt;td style="text-align:right;"&gt;&lt;strong&gt;Product:&lt;/strong&gt;&lt;/td&gt;
&lt;td&gt;STAAD.pro&lt;/td&gt;
&lt;td&gt;&lt;/td&gt;
&lt;/tr&gt;
&lt;tr&gt;
&lt;td style="text-align:right;"&gt;&lt;strong&gt;&lt;/strong&gt;&lt;/td&gt;
&lt;td style="text-align:right;"&gt;&lt;strong&gt;First Affected Version:&lt;/strong&gt;&lt;/td&gt;
&lt;td&gt;21.00.02.30&lt;/td&gt;
&lt;td&gt;&lt;/td&gt;
&lt;/tr&gt;
&lt;tr&gt;
&lt;td style="text-align:right;"&gt;&lt;strong&gt;&amp;nbsp;&lt;/strong&gt;&lt;/td&gt;
&lt;td style="text-align:right;"&gt;&lt;strong&gt;Found in Version:&lt;/strong&gt;&lt;/td&gt;
&lt;td&gt;21.00.02.30&lt;/td&gt;
&lt;td&gt;&lt;/td&gt;
&lt;/tr&gt;
&lt;tr&gt;
&lt;td style="text-align:right;"&gt;&lt;strong&gt;&lt;/strong&gt;&lt;/td&gt;
&lt;td style="text-align:right;"&gt;&lt;strong&gt;Fixed and Released in Version:&lt;/strong&gt;&lt;/td&gt;
&lt;td&gt;&lt;span style="color:#008000;"&gt;&lt;strong&gt;21.03.00.146&lt;/strong&gt;&lt;/span&gt;&lt;/td&gt;
&lt;td&gt;&lt;/td&gt;
&lt;/tr&gt;
&lt;tr&gt;
&lt;td style="text-align:right;"&gt;&lt;strong&gt;&amp;nbsp;&lt;/strong&gt;&lt;/td&gt;
&lt;td style="text-align:right;"&gt;&lt;strong&gt;Area:&amp;nbsp;&lt;/strong&gt;&lt;/td&gt;
&lt;td&gt;Custom Steel&amp;nbsp;Section Database&lt;/td&gt;
&lt;td&gt;&lt;/td&gt;
&lt;/tr&gt;
&lt;tr&gt;
&lt;td style="text-align:right;"&gt;&lt;strong&gt;&amp;nbsp;&lt;/strong&gt;&lt;/td&gt;
&lt;td style="text-align:right;"&gt;&lt;strong&gt;Issue #:&lt;/strong&gt;&lt;/td&gt;
&lt;td&gt;870111&lt;/td&gt;
&lt;td&gt;&lt;/td&gt;
&lt;/tr&gt;
&lt;/tbody&gt;
&lt;/table&gt;
&lt;h1&gt;Problem Description&lt;/h1&gt;
&lt;p&gt;Older custom steel section databases created by users do not show up within the Section Database for the STAAD.Pro Connect Edition.&lt;/p&gt;
&lt;p&gt;Details on how to convert older section database files (mdb) to the newer format (.db3)&amp;nbsp;can be found &lt;a href="/products/ram-staad/w/structural_analysis_and_design__wiki/38174/migrating-existing-custom-steel-section-databases-to-the-staad-pro-connect-edition"&gt;here&lt;/a&gt;&lt;/p&gt;
&lt;p&gt;&lt;span style="color:#ff0000;font-size:150%;"&gt;&lt;em&gt;&lt;strong&gt;&amp;nbsp;&lt;/strong&gt;&lt;/em&gt;&lt;/span&gt;&lt;/p&gt;
&lt;p&gt;.&lt;/p&gt;
&lt;p&gt;&lt;span style="font-size:200%;"&gt;&lt;strong&gt;Steps to Reproduce&lt;/strong&gt;&lt;/span&gt;&lt;/p&gt;
&lt;ol&gt;
&lt;li&gt;Copy the older section database file (let&amp;rsquo;s say &amp;ldquo;aiscsections_ml_SLS.db3&amp;rdquo;) into the Sections folder of the installation [C:\ProgramData\Bentley\Engineering\STAAD.Pro CONNECT Edition\Sections]&lt;/li&gt;
&lt;li&gt;Go to Specification &amp;gt; Section Database and the new database does not show up&lt;/li&gt;
&lt;/ol&gt;
&lt;h1&gt;Workaround&lt;/h1&gt;
&lt;ol&gt;
&lt;li&gt;Go to the user profile folder &amp;ldquo;C:\Users\&amp;lt;user profile name&amp;gt;\AppData\Local\Bentley\Engineering\STAAD.Pro CONNECT Edition\Default\Sections&amp;rdquo;&lt;/li&gt;
&lt;li&gt;Open the&amp;nbsp;&amp;ldquo;Custom.ini&amp;rdquo; using Notepad or Worpad&lt;/li&gt;
&lt;li&gt;Search for &amp;lsquo;[CustomDBFlags]&amp;rsquo;&lt;/li&gt;
&lt;li&gt;Under the above section, Set &amp;lsquo;1&amp;rsquo; against &amp;lsquo;AISCSections&amp;rsquo;&lt;/li&gt;
&lt;li&gt;Next, search for &amp;lsquo;[CustomDBNames]&amp;rsquo;&lt;/li&gt;
&lt;li&gt;Under this section, Set &amp;lsquo;aiscsections_ml_SLS&amp;rsquo; against &amp;lsquo;AISCSections&amp;rsquo;&lt;/li&gt;
&lt;li&gt;&amp;nbsp;&lt;img alt=" " src="/resized-image/__size/640x480/__key/communityserver-wikis-components-files/00-00-00-00-54/1440.1.jpg" /&gt;&lt;/li&gt;
&lt;li&gt;Now, copy the &amp;lsquo;aiscsections_ml_SLS.db3&amp;rsquo; database to &amp;lsquo;C:\ProgramData\Bentley\Engineering\STAAD.Pro CONNECT Edition\Sections&amp;rsquo;&lt;/li&gt;
&lt;li&gt;There are a couple of more copies of the &amp;ldquo;Custom.ini&amp;rdquo; file within the following folders.&lt;/li&gt;
&lt;li&gt;C:\Program Files\Bentley\Engineering\STAAD.Pro CONNECT Edition\STAAD\Sections&lt;/li&gt;
&lt;li&gt;C:\ProgramData\Bentley\Engineering\STAAD.Pro CONNECT Edition\Sections&lt;/li&gt;
&lt;li&gt;In case you do not see the same entries updated in those files, please go ahead and manually change the data as suggested in steps 3 to 6 in these files too.&lt;/li&gt;
&lt;li&gt;StaadPro should now pick up sections from the above user database.&lt;/li&gt;
&lt;/ol&gt;
&lt;p&gt;&lt;/p&gt;
&lt;p&gt;Note : You may not be able to launch the Section Database Manager from within the Specification ribbon menu after you make the change. However the user sections should be accessible&lt;/p&gt;
&lt;p&gt;&lt;strong&gt;&lt;span style="font-size:200%;"&gt;Solution&lt;/span&gt;&lt;/strong&gt;&lt;/p&gt;
&lt;p&gt;&lt;span style="color:#008000;"&gt;&lt;strong&gt;The problem has been addressed in the STAAD.Pro Connect Edition&amp;nbsp;version 21.03.00.146.&amp;nbsp;&lt;/strong&gt;&lt;/span&gt;&lt;/p&gt;
&lt;p&gt;&lt;/p&gt;
&lt;p&gt;&lt;b&gt;&lt;img alt=" " height="60" src="/cfs-file.ashx/__key/communityserver-components-sitefiles/TSG-Logo.png" width="189" /&gt;&lt;/b&gt;&lt;/p&gt;&lt;div style="clear:both;"&gt;&lt;/div&gt;

&lt;div style="font-size: 90%;"&gt;Tags: custom section database, section database, known issue, db3, user section, Database, 21.00.02.30&lt;/div&gt;
</description></item><item><title>Existing custom steel section databases cannot be opened in the STAAD.Pro Connect Edition</title><link>https://communities.bentley.com/products/ram-staad/w/structural_analysis_and_design__wiki/38173/existing-custom-steel-section-databases-cannot-be-opened-in-the-staad-pro-connect-edition/revision/4</link><pubDate>Fri, 06 Apr 2018 23:19:47 GMT</pubDate><guid isPermaLink="false">6dad98f5-dbc9-4c4d-a9ba-e9da8dc6aa8e:7d37d914-2b9f-4d1c-ab4d-9e29524b1f0e</guid><dc:creator>Sye</dc:creator><comments>https://communities.bentley.com/products/ram-staad/w/structural_analysis_and_design__wiki/38173/existing-custom-steel-section-databases-cannot-be-opened-in-the-staad-pro-connect-edition#comments</comments><description>Revision 4 posted to RAM | STAAD | ADINA Wiki by Sye on 4/6/2018 11:19:47 PM&lt;br /&gt;
&lt;table style="background-color:#dce5f0;border:0px solid #dce5f0;width:500px;" align="left" border="0"&gt;
&lt;tbody&gt;
&lt;tr&gt;
&lt;td style="text-align:right;"&gt;&lt;strong&gt;&amp;nbsp;&lt;/strong&gt;&lt;/td&gt;
&lt;td style="text-align:right;"&gt;&lt;strong&gt;Product:&lt;/strong&gt;&lt;/td&gt;
&lt;td&gt;STAAD.pro&lt;/td&gt;
&lt;td&gt;&lt;/td&gt;
&lt;/tr&gt;
&lt;tr&gt;
&lt;td style="text-align:right;"&gt;&lt;strong&gt;&lt;/strong&gt;&lt;/td&gt;
&lt;td style="text-align:right;"&gt;&lt;strong&gt;First Affected Version:&lt;/strong&gt;&lt;/td&gt;
&lt;td&gt;21.00.02.30&lt;/td&gt;
&lt;td&gt;&lt;/td&gt;
&lt;/tr&gt;
&lt;tr&gt;
&lt;td style="text-align:right;"&gt;&lt;strong&gt;&amp;nbsp;&lt;/strong&gt;&lt;/td&gt;
&lt;td style="text-align:right;"&gt;&lt;strong&gt;Found in Version:&lt;/strong&gt;&lt;/td&gt;
&lt;td&gt;21.00.02.30&lt;/td&gt;
&lt;td&gt;&lt;/td&gt;
&lt;/tr&gt;
&lt;tr&gt;
&lt;td style="text-align:right;"&gt;&lt;strong&gt;&lt;/strong&gt;&lt;/td&gt;
&lt;td style="text-align:right;"&gt;&lt;strong&gt;Fixed and Released in Version:&lt;/strong&gt;&lt;/td&gt;
&lt;td&gt;&lt;/td&gt;
&lt;td&gt;&lt;/td&gt;
&lt;/tr&gt;
&lt;tr&gt;
&lt;td style="text-align:right;"&gt;&lt;strong&gt;&amp;nbsp;&lt;/strong&gt;&lt;/td&gt;
&lt;td style="text-align:right;"&gt;&lt;strong&gt;Area:&amp;nbsp;&lt;/strong&gt;&lt;/td&gt;
&lt;td&gt;Custom Steel&amp;nbsp;Section Database&lt;/td&gt;
&lt;td&gt;&lt;/td&gt;
&lt;/tr&gt;
&lt;tr&gt;
&lt;td style="text-align:right;"&gt;&lt;strong&gt;&amp;nbsp;&lt;/strong&gt;&lt;/td&gt;
&lt;td style="text-align:right;"&gt;&lt;strong&gt;Issue #:&lt;/strong&gt;&lt;/td&gt;
&lt;td&gt;870111&lt;/td&gt;
&lt;td&gt;&lt;/td&gt;
&lt;/tr&gt;
&lt;/tbody&gt;
&lt;/table&gt;
&lt;h1&gt;Problem Description&lt;/h1&gt;
&lt;p&gt;Older custom steel section databases created by users do not show up within the Section Database for the STAAD.Pro Connect Edition.&lt;/p&gt;
&lt;p&gt;Details on how to convert older section database files (mdb) to the newer format (.db3)&amp;nbsp;can be found &lt;a href="/products/ram-staad/w/structural_analysis_and_design__wiki/38174/migrating-existing-custom-steel-section-databases-to-the-staad-pro-connect-edition"&gt;here&lt;/a&gt;&lt;/p&gt;
&lt;p&gt;&lt;span style="color:#ff0000;font-size:150%;"&gt;&lt;em&gt;&lt;strong&gt;&amp;nbsp;&lt;/strong&gt;&lt;/em&gt;&lt;/span&gt;&lt;/p&gt;
&lt;p&gt;.&lt;/p&gt;
&lt;p&gt;&lt;span style="font-size:200%;"&gt;&lt;strong&gt;Steps to Reproduce&lt;/strong&gt;&lt;/span&gt;&lt;/p&gt;
&lt;ol&gt;
&lt;li&gt;Copy the older section database file (let&amp;rsquo;s say &amp;ldquo;aiscsections_ml_SLS.db3&amp;rdquo;) into the Sections folder of the installation [C:\ProgramData\Bentley\Engineering\STAAD.Pro CONNECT Edition\Sections]&lt;/li&gt;
&lt;li&gt;Go to Specification &amp;gt; Section Database and the new database does not show up&lt;/li&gt;
&lt;/ol&gt;
&lt;h1&gt;Workaround&lt;/h1&gt;
&lt;ol&gt;
&lt;li&gt;Go to the user profile folder &amp;ldquo;C:\Users\&amp;lt;user profile name&amp;gt;\AppData\Local\Bentley\Engineering\STAAD.Pro CONNECT Edition\Default\Sections&amp;rdquo;&lt;/li&gt;
&lt;li&gt;Open the&amp;nbsp;&amp;ldquo;Custom.ini&amp;rdquo; using Notepad or Worpad&lt;/li&gt;
&lt;li&gt;Search for &amp;lsquo;[CustomDBFlags]&amp;rsquo;&lt;/li&gt;
&lt;li&gt;Under the above section, Set &amp;lsquo;1&amp;rsquo; against &amp;lsquo;AISCSections&amp;rsquo;&lt;/li&gt;
&lt;li&gt;Next, search for &amp;lsquo;[CustomDBNames]&amp;rsquo;&lt;/li&gt;
&lt;li&gt;Under this section, Set &amp;lsquo;aiscsections_ml_SLS&amp;rsquo; against &amp;lsquo;AISCSections&amp;rsquo;&lt;/li&gt;
&lt;li&gt;&amp;nbsp;&lt;img alt=" " src="/resized-image/__size/640x480/__key/communityserver-wikis-components-files/00-00-00-00-54/1440.1.jpg" /&gt;&lt;/li&gt;
&lt;li&gt;Now, copy the &amp;lsquo;aiscsections_ml_SLS.db3&amp;rsquo; database to &amp;lsquo;C:\ProgramData\Bentley\Engineering\STAAD.Pro CONNECT Edition\Sections&amp;rsquo;&lt;/li&gt;
&lt;li&gt;There are a couple of more copies of the &amp;ldquo;Custom.ini&amp;rdquo; file within the following folders.&lt;/li&gt;
&lt;li&gt;C:\Program Files\Bentley\Engineering\STAAD.Pro CONNECT Edition\STAAD\Sections&lt;/li&gt;
&lt;li&gt;C:\ProgramData\Bentley\Engineering\STAAD.Pro CONNECT Edition\Sections&lt;/li&gt;
&lt;li&gt;In case you do not see the same entries updated in those files, please go ahead and manually change the data as suggested in steps 3 to 6 in these files too.&lt;/li&gt;
&lt;li&gt;StaadPro should now pick up sections from the above user database.&lt;/li&gt;
&lt;/ol&gt;
&lt;p&gt;&lt;/p&gt;
&lt;p&gt;Note : You may not be able to launch the Section Database Manager from within the Specification ribbon menu after you make the change. However the user sections should be accessible&lt;/p&gt;
&lt;p&gt;&lt;strong&gt;&lt;span style="font-size:200%;"&gt;Solution&lt;/span&gt;&lt;/strong&gt;&lt;/p&gt;
&lt;p&gt;The problem&amp;nbsp;will be addressed in the STAAD.Pro Connect Edition&amp;nbsp;Update&amp;nbsp;3 .&amp;nbsp;&lt;/p&gt;
&lt;p&gt;&lt;/p&gt;
&lt;p&gt;&lt;b&gt;&lt;img alt=" " height="60" src="/cfs-file.ashx/__key/communityserver-components-sitefiles/TSG-Logo.png" width="189" /&gt;&lt;/b&gt;&lt;/p&gt;&lt;div style="clear:both;"&gt;&lt;/div&gt;

&lt;div style="font-size: 90%;"&gt;Tags: custom section database, section database, known issue, db3, user section, Database, 21.00.02.30&lt;/div&gt;
</description></item><item><title>Existing custom steel section databases cannot be opened in the STAAD.Pro Connect Edition</title><link>https://communities.bentley.com/products/ram-staad/w/structural_analysis_and_design__wiki/38173/existing-custom-steel-section-databases-cannot-be-opened-in-the-staad-pro-connect-edition/revision/3</link><pubDate>Fri, 06 Apr 2018 22:33:54 GMT</pubDate><guid isPermaLink="false">6dad98f5-dbc9-4c4d-a9ba-e9da8dc6aa8e:7d37d914-2b9f-4d1c-ab4d-9e29524b1f0e</guid><dc:creator>Sye</dc:creator><comments>https://communities.bentley.com/products/ram-staad/w/structural_analysis_and_design__wiki/38173/existing-custom-steel-section-databases-cannot-be-opened-in-the-staad-pro-connect-edition#comments</comments><description>Revision 3 posted to RAM | STAAD | ADINA Wiki by Sye on 4/6/2018 10:33:54 PM&lt;br /&gt;
&lt;table style="background-color:#dce5f0;border:0px solid #dce5f0;width:500px;" align="left" border="0"&gt;
&lt;tbody&gt;
&lt;tr&gt;
&lt;td style="text-align:right;"&gt;&lt;strong&gt;&amp;nbsp;&lt;/strong&gt;&lt;/td&gt;
&lt;td style="text-align:right;"&gt;&lt;strong&gt;Product:&lt;/strong&gt;&lt;/td&gt;
&lt;td&gt;STAAD.pro&lt;/td&gt;
&lt;td&gt;&lt;/td&gt;
&lt;/tr&gt;
&lt;tr&gt;
&lt;td style="text-align:right;"&gt;&lt;strong&gt;&lt;/strong&gt;&lt;/td&gt;
&lt;td style="text-align:right;"&gt;&lt;strong&gt;First Affected Version:&lt;/strong&gt;&lt;/td&gt;
&lt;td&gt;21.00.02.30&lt;/td&gt;
&lt;td&gt;&lt;/td&gt;
&lt;/tr&gt;
&lt;tr&gt;
&lt;td style="text-align:right;"&gt;&lt;strong&gt;&amp;nbsp;&lt;/strong&gt;&lt;/td&gt;
&lt;td style="text-align:right;"&gt;&lt;strong&gt;Found in Version:&lt;/strong&gt;&lt;/td&gt;
&lt;td&gt;21.00.02.30&lt;/td&gt;
&lt;td&gt;&lt;/td&gt;
&lt;/tr&gt;
&lt;tr&gt;
&lt;td style="text-align:right;"&gt;&lt;strong&gt;&lt;/strong&gt;&lt;/td&gt;
&lt;td style="text-align:right;"&gt;&lt;strong&gt;Fixed and Released in Version:&lt;/strong&gt;&lt;/td&gt;
&lt;td&gt;&lt;/td&gt;
&lt;td&gt;&lt;/td&gt;
&lt;/tr&gt;
&lt;tr&gt;
&lt;td style="text-align:right;"&gt;&lt;strong&gt;&amp;nbsp;&lt;/strong&gt;&lt;/td&gt;
&lt;td style="text-align:right;"&gt;&lt;strong&gt;Area:&amp;nbsp;&lt;/strong&gt;&lt;/td&gt;
&lt;td&gt;Custom Steel&amp;nbsp;Section Database&lt;/td&gt;
&lt;td&gt;&lt;/td&gt;
&lt;/tr&gt;
&lt;tr&gt;
&lt;td style="text-align:right;"&gt;&lt;strong&gt;&amp;nbsp;&lt;/strong&gt;&lt;/td&gt;
&lt;td style="text-align:right;"&gt;&lt;strong&gt;Issue #:&lt;/strong&gt;&lt;/td&gt;
&lt;td&gt;870111&lt;/td&gt;
&lt;td&gt;&lt;/td&gt;
&lt;/tr&gt;
&lt;/tbody&gt;
&lt;/table&gt;
&lt;h1&gt;Problem Description&lt;/h1&gt;
&lt;p&gt;Older custom steel section databases created by users do not show up within the Section Database for the STAAD.Pro Connect Edition.&lt;/p&gt;
&lt;p&gt;&lt;/p&gt;
&lt;p&gt;&lt;span style="color:#ff0000;font-size:150%;"&gt;&lt;em&gt;&lt;strong&gt;&amp;nbsp;&lt;/strong&gt;&lt;/em&gt;&lt;/span&gt;&lt;/p&gt;
&lt;p&gt;.&lt;/p&gt;
&lt;p&gt;&lt;span style="font-size:200%;"&gt;&lt;strong&gt;Steps to Reproduce&lt;/strong&gt;&lt;/span&gt;&lt;/p&gt;
&lt;ol&gt;
&lt;li&gt;Copy the older section database file (let&amp;rsquo;s say &amp;ldquo;aiscsections_ml_SLS.db3&amp;rdquo;) into the Sections folder of the installation [C:\ProgramData\Bentley\Engineering\STAAD.Pro CONNECT Edition\Sections]&lt;/li&gt;
&lt;li&gt;Go to Specification &amp;gt; Section Database and the new database does not show up&lt;/li&gt;
&lt;/ol&gt;
&lt;h1&gt;Workaround&lt;/h1&gt;
&lt;ol&gt;
&lt;li&gt;Go to the user profile folder &amp;ldquo;C:\Users\&amp;lt;user profile name&amp;gt;\AppData\Local\Bentley\Engineering\STAAD.Pro CONNECT Edition\Default\Sections&amp;rdquo;&lt;/li&gt;
&lt;li&gt;Open the&amp;nbsp;&amp;ldquo;Custom.ini&amp;rdquo; using Notepad or Worpad&lt;/li&gt;
&lt;li&gt;Search for &amp;lsquo;[CustomDBFlags]&amp;rsquo;&lt;/li&gt;
&lt;li&gt;Under the above section, Set &amp;lsquo;1&amp;rsquo; against &amp;lsquo;AISCSections&amp;rsquo;&lt;/li&gt;
&lt;li&gt;Next, search for &amp;lsquo;[CustomDBNames]&amp;rsquo;&lt;/li&gt;
&lt;li&gt;Under this section, Set &amp;lsquo;aiscsections_ml_SLS&amp;rsquo; against &amp;lsquo;AISCSections&amp;rsquo;&lt;/li&gt;
&lt;li&gt;&amp;nbsp;&lt;img alt=" " src="/resized-image/__size/640x480/__key/communityserver-wikis-components-files/00-00-00-00-54/1440.1.jpg" /&gt;&lt;/li&gt;
&lt;li&gt;Now, copy the &amp;lsquo;aiscsections_ml_SLS.db3&amp;rsquo; database to &amp;lsquo;C:\ProgramData\Bentley\Engineering\STAAD.Pro CONNECT Edition\Sections&amp;rsquo;&lt;/li&gt;
&lt;li&gt;There are a couple of more copies of the &amp;ldquo;Custom.ini&amp;rdquo; file within the following folders.&lt;/li&gt;
&lt;li&gt;C:\Program Files\Bentley\Engineering\STAAD.Pro CONNECT Edition\STAAD\Sections&lt;/li&gt;
&lt;li&gt;C:\ProgramData\Bentley\Engineering\STAAD.Pro CONNECT Edition\Sections&lt;/li&gt;
&lt;li&gt;In case you do not see the same entries updated in those files, please go ahead and manually change the data as suggested in steps 3 to 6 in these files too.&lt;/li&gt;
&lt;li&gt;StaadPro should now pick up sections from the above user database.&lt;/li&gt;
&lt;/ol&gt;
&lt;p&gt;&lt;/p&gt;
&lt;p&gt;Note : You may not be able to launch the Section Database Manager from within the Specification ribbon menu after you make the change. However the user sections should be accessible&lt;/p&gt;
&lt;p&gt;&lt;strong&gt;&lt;span style="font-size:200%;"&gt;Solution&lt;/span&gt;&lt;/strong&gt;&lt;/p&gt;
&lt;p&gt;The problem&amp;nbsp;will be addressed in the STAAD.Pro Connect Edition&amp;nbsp;Update&amp;nbsp;3 .&amp;nbsp;&lt;/p&gt;
&lt;p&gt;&lt;/p&gt;
&lt;p&gt;&lt;b&gt;&lt;img alt=" " height="60" src="/cfs-file.ashx/__key/communityserver-components-sitefiles/TSG-Logo.png" width="189" /&gt;&lt;/b&gt;&lt;/p&gt;&lt;div style="clear:both;"&gt;&lt;/div&gt;

&lt;div style="font-size: 90%;"&gt;Tags: custom section database, section database, known issue, db3, user section, Database, 21.00.02.30&lt;/div&gt;
</description></item><item><title>Existing custom steel section databases cannot opened in the STAAD.Pro Connect Edition</title><link>https://communities.bentley.com/products/ram-staad/w/structural_analysis_and_design__wiki/38173/existing-custom-steel-section-databases-cannot-be-opened-in-the-staad-pro-connect-edition/revision/2</link><pubDate>Fri, 06 Apr 2018 22:27:56 GMT</pubDate><guid isPermaLink="false">6dad98f5-dbc9-4c4d-a9ba-e9da8dc6aa8e:7d37d914-2b9f-4d1c-ab4d-9e29524b1f0e</guid><dc:creator>Sye</dc:creator><comments>https://communities.bentley.com/products/ram-staad/w/structural_analysis_and_design__wiki/38173/existing-custom-steel-section-databases-cannot-be-opened-in-the-staad-pro-connect-edition#comments</comments><description>Revision 2 posted to RAM | STAAD | ADINA Wiki by Sye on 4/6/2018 10:27:56 PM&lt;br /&gt;
&lt;table style="background-color:#dce5f0;border:0px solid #dce5f0;width:500px;" align="left" border="0"&gt;
&lt;tbody&gt;
&lt;tr&gt;
&lt;td style="text-align:right;"&gt;&lt;strong&gt;&amp;nbsp;&lt;/strong&gt;&lt;/td&gt;
&lt;td style="text-align:right;"&gt;&lt;strong&gt;Product:&lt;/strong&gt;&lt;/td&gt;
&lt;td&gt;STAAD.pro&lt;/td&gt;
&lt;td&gt;&lt;/td&gt;
&lt;/tr&gt;
&lt;tr&gt;
&lt;td style="text-align:right;"&gt;&lt;strong&gt;&lt;/strong&gt;&lt;/td&gt;
&lt;td style="text-align:right;"&gt;&lt;strong&gt;First Affected Version:&lt;/strong&gt;&lt;/td&gt;
&lt;td&gt;21.00.02.30&lt;/td&gt;
&lt;td&gt;&lt;/td&gt;
&lt;/tr&gt;
&lt;tr&gt;
&lt;td style="text-align:right;"&gt;&lt;strong&gt;&amp;nbsp;&lt;/strong&gt;&lt;/td&gt;
&lt;td style="text-align:right;"&gt;&lt;strong&gt;Found in Version:&lt;/strong&gt;&lt;/td&gt;
&lt;td&gt;21.00.02.30&lt;/td&gt;
&lt;td&gt;&lt;/td&gt;
&lt;/tr&gt;
&lt;tr&gt;
&lt;td style="text-align:right;"&gt;&lt;strong&gt;&lt;/strong&gt;&lt;/td&gt;
&lt;td style="text-align:right;"&gt;&lt;strong&gt;Fixed and Released in Version:&lt;/strong&gt;&lt;/td&gt;
&lt;td&gt;&lt;/td&gt;
&lt;td&gt;&lt;/td&gt;
&lt;/tr&gt;
&lt;tr&gt;
&lt;td style="text-align:right;"&gt;&lt;strong&gt;&amp;nbsp;&lt;/strong&gt;&lt;/td&gt;
&lt;td style="text-align:right;"&gt;&lt;strong&gt;Area:&amp;nbsp;&lt;/strong&gt;&lt;/td&gt;
&lt;td&gt;Custom Steel&amp;nbsp;Section Database&lt;/td&gt;
&lt;td&gt;&lt;/td&gt;
&lt;/tr&gt;
&lt;tr&gt;
&lt;td style="text-align:right;"&gt;&lt;strong&gt;&amp;nbsp;&lt;/strong&gt;&lt;/td&gt;
&lt;td style="text-align:right;"&gt;&lt;strong&gt;Issue #:&lt;/strong&gt;&lt;/td&gt;
&lt;td&gt;870111&lt;/td&gt;
&lt;td&gt;&lt;/td&gt;
&lt;/tr&gt;
&lt;/tbody&gt;
&lt;/table&gt;
&lt;h1&gt;Problem Description&lt;/h1&gt;
&lt;p&gt;Older custom steel section databases created by users do not show up within the Section Database for the STAAD.Pro Connect Edition.&lt;/p&gt;
&lt;p&gt;&lt;/p&gt;
&lt;p&gt;&lt;span style="color:#ff0000;font-size:150%;"&gt;&lt;em&gt;&lt;strong&gt;&amp;nbsp;&lt;/strong&gt;&lt;/em&gt;&lt;/span&gt;&lt;/p&gt;
&lt;p&gt;.&lt;/p&gt;
&lt;p&gt;&lt;span style="font-size:200%;"&gt;&lt;strong&gt;Steps to Reproduce&lt;/strong&gt;&lt;/span&gt;&lt;/p&gt;
&lt;ol&gt;
&lt;li&gt;Copy the older section database file (let&amp;rsquo;s say &amp;ldquo;aiscsections_ml_SLS.db3&amp;rdquo;) into the Sections folder of the installation [C:\ProgramData\Bentley\Engineering\STAAD.Pro CONNECT Edition\Sections]&lt;/li&gt;
&lt;li&gt;Go to Specification &amp;gt; Section Database and the new database does not show up&lt;/li&gt;
&lt;/ol&gt;
&lt;h1&gt;Workaround&lt;/h1&gt;
&lt;ol&gt;
&lt;li&gt;Go to the user profile folder &amp;ldquo;C:\Users\&amp;lt;user profile name&amp;gt;\AppData\Local\Bentley\Engineering\STAAD.Pro CONNECT Edition\Default\Sections&amp;rdquo;&lt;/li&gt;
&lt;li&gt;Open the&amp;nbsp;&amp;ldquo;Custom.ini&amp;rdquo; using Notepad or Worpad&lt;/li&gt;
&lt;li&gt;Search for &amp;lsquo;[CustomDBFlags]&amp;rsquo;&lt;/li&gt;
&lt;li&gt;Under the above section, Set &amp;lsquo;1&amp;rsquo; against &amp;lsquo;AISCSections&amp;rsquo;&lt;/li&gt;
&lt;li&gt;Next, search for &amp;lsquo;[CustomDBNames]&amp;rsquo;&lt;/li&gt;
&lt;li&gt;Under this section, Set &amp;lsquo;aiscsections_ml_SLS&amp;rsquo; against &amp;lsquo;AISCSections&amp;rsquo;&lt;/li&gt;
&lt;li&gt;&amp;nbsp;&lt;img alt=" " src="/resized-image/__size/640x480/__key/communityserver-wikis-components-files/00-00-00-00-54/1440.1.jpg" /&gt;&lt;/li&gt;
&lt;li&gt;Now, copy the &amp;lsquo;aiscsections_ml_SLS.db3&amp;rsquo; database to &amp;lsquo;C:\ProgramData\Bentley\Engineering\STAAD.Pro CONNECT Edition\Sections&amp;rsquo;&lt;/li&gt;
&lt;li&gt;There are a couple of more copies of the &amp;ldquo;Custom.ini&amp;rdquo; file within the following folders.&lt;/li&gt;
&lt;li&gt;C:\Program Files\Bentley\Engineering\STAAD.Pro CONNECT Edition\STAAD\Sections&lt;/li&gt;
&lt;li&gt;C:\ProgramData\Bentley\Engineering\STAAD.Pro CONNECT Edition\Sections&lt;/li&gt;
&lt;li&gt;In case you do not see the same entries updated in those files, please go ahead and manually change the data as suggested in steps 3 to 6 in these files too.&lt;/li&gt;
&lt;li&gt;StaadPro should now pick up sections from the above user database.&lt;/li&gt;
&lt;/ol&gt;
&lt;p&gt;&lt;/p&gt;
&lt;p&gt;Note : You may not be able to launch the Section Database Manager from within the Specification ribbon menu after you make the change. However the user sections should be accessible&lt;/p&gt;
&lt;p&gt;&lt;strong&gt;&lt;span style="font-size:200%;"&gt;Solution&lt;/span&gt;&lt;/strong&gt;&lt;/p&gt;
&lt;p&gt;The problem&amp;nbsp;will be addressed in the STAAD.Pro Connect Edition&amp;nbsp;Update&amp;nbsp;3 .&amp;nbsp;&lt;/p&gt;
&lt;p&gt;&lt;/p&gt;
&lt;p&gt;&lt;b&gt;&lt;img alt=" " height="60" src="/cfs-file.ashx/__key/communityserver-components-sitefiles/TSG-Logo.png" width="189" /&gt;&lt;/b&gt;&lt;/p&gt;&lt;div style="clear:both;"&gt;&lt;/div&gt;

&lt;div style="font-size: 90%;"&gt;Tags: custom section database, section database, known issue, db3, user section, Database, 21.00.02.30&lt;/div&gt;
</description></item><item><title>Existing custom steel section databases cannot opened in the STAAD.Pro Connect Edition</title><link>https://communities.bentley.com/products/ram-staad/w/structural_analysis_and_design__wiki/38173/existing-custom-steel-section-databases-cannot-be-opened-in-the-staad-pro-connect-edition/revision/1</link><pubDate>Fri, 06 Apr 2018 22:24:43 GMT</pubDate><guid isPermaLink="false">6dad98f5-dbc9-4c4d-a9ba-e9da8dc6aa8e:7d37d914-2b9f-4d1c-ab4d-9e29524b1f0e</guid><dc:creator>Sye</dc:creator><comments>https://communities.bentley.com/products/ram-staad/w/structural_analysis_and_design__wiki/38173/existing-custom-steel-section-databases-cannot-be-opened-in-the-staad-pro-connect-edition#comments</comments><description>Revision 1 posted to RAM | STAAD | ADINA Wiki by Sye on 4/6/2018 10:24:43 PM&lt;br /&gt;
&lt;table style="background-color:#dce5f0;border:0px solid #dce5f0;width:500px;" align="left" border="0"&gt;
&lt;tbody&gt;
&lt;tr&gt;
&lt;td style="text-align:right;"&gt;&lt;strong&gt;&amp;nbsp;&lt;/strong&gt;&lt;/td&gt;
&lt;td style="text-align:right;"&gt;&lt;strong&gt;Product:&lt;/strong&gt;&lt;/td&gt;
&lt;td&gt;STAAD.pro&lt;/td&gt;
&lt;td&gt;&lt;/td&gt;
&lt;/tr&gt;
&lt;tr&gt;
&lt;td style="text-align:right;"&gt;&lt;strong&gt;&lt;/strong&gt;&lt;/td&gt;
&lt;td style="text-align:right;"&gt;&lt;strong&gt;First Affected Version:&lt;/strong&gt;&lt;/td&gt;
&lt;td&gt;21.00.02.30&lt;/td&gt;
&lt;td&gt;&lt;/td&gt;
&lt;/tr&gt;
&lt;tr&gt;
&lt;td style="text-align:right;"&gt;&lt;strong&gt;&amp;nbsp;&lt;/strong&gt;&lt;/td&gt;
&lt;td style="text-align:right;"&gt;&lt;strong&gt;Found in Version:&lt;/strong&gt;&lt;/td&gt;
&lt;td&gt;21.00.02.30&lt;/td&gt;
&lt;td&gt;&lt;/td&gt;
&lt;/tr&gt;
&lt;tr&gt;
&lt;td style="text-align:right;"&gt;&lt;strong&gt;&lt;/strong&gt;&lt;/td&gt;
&lt;td style="text-align:right;"&gt;&lt;strong&gt;Fixed and Released in Version:&lt;/strong&gt;&lt;/td&gt;
&lt;td&gt;&lt;/td&gt;
&lt;td&gt;&lt;/td&gt;
&lt;/tr&gt;
&lt;tr&gt;
&lt;td style="text-align:right;"&gt;&lt;strong&gt;&amp;nbsp;&lt;/strong&gt;&lt;/td&gt;
&lt;td style="text-align:right;"&gt;&lt;strong&gt;Area:&amp;nbsp;&lt;/strong&gt;&lt;/td&gt;
&lt;td&gt;Custom Steel&amp;nbsp;Section Database&lt;/td&gt;
&lt;td&gt;&lt;/td&gt;
&lt;/tr&gt;
&lt;tr&gt;
&lt;td style="text-align:right;"&gt;&lt;strong&gt;&amp;nbsp;&lt;/strong&gt;&lt;/td&gt;
&lt;td style="text-align:right;"&gt;&lt;strong&gt;Issue #:&lt;/strong&gt;&lt;/td&gt;
&lt;td&gt;870111&lt;/td&gt;
&lt;td&gt;&lt;/td&gt;
&lt;/tr&gt;
&lt;/tbody&gt;
&lt;/table&gt;
&lt;h1&gt;Problem Description&lt;/h1&gt;
&lt;p&gt;Older custom steel section databases created by users do not show up within the Section Database for the STAAD.Pro Connect Edition.&lt;/p&gt;
&lt;p&gt;&lt;/p&gt;
&lt;p&gt;&lt;span style="color:#ff0000;font-size:150%;"&gt;&lt;em&gt;&lt;strong&gt;&amp;nbsp;&lt;/strong&gt;&lt;/em&gt;&lt;/span&gt;&lt;/p&gt;
&lt;p&gt;.&lt;/p&gt;
&lt;p&gt;&lt;span style="font-size:200%;"&gt;&lt;strong&gt;Steps to Reproduce&lt;/strong&gt;&lt;/span&gt;&lt;/p&gt;
&lt;ol&gt;
&lt;li&gt;Copy the older section database file (let&amp;rsquo;s say &amp;ldquo;aiscsections_ml_SLS.db3&amp;rdquo;) into the Sections folder of the installation [C:\ProgramData\Bentley\Engineering\STAAD.Pro CONNECT Edition\Sections]&lt;/li&gt;
&lt;li&gt;Go to Specification &amp;gt; Section Database and the new database does not show up&lt;/li&gt;
&lt;/ol&gt;
&lt;h1&gt;Workaround&lt;/h1&gt;
&lt;ol&gt;
&lt;li&gt;Go to the user profile folder &amp;ldquo;C:\Users\&amp;lt;user profile name&amp;gt;\AppData\Local\Bentley\Engineering\STAAD.Pro CONNECT Edition\Default\Sections&amp;rdquo;&lt;/li&gt;
&lt;li&gt;Open the&amp;nbsp;&amp;ldquo;Custom.ini&amp;rdquo; using Notepad or Worpad&lt;/li&gt;
&lt;li&gt;Search for &amp;lsquo;[CustomDBFlags]&amp;rsquo;&lt;/li&gt;
&lt;li&gt;Under the above section, Set &amp;lsquo;1&amp;rsquo; against &amp;lsquo;AISCSections&amp;rsquo;&lt;/li&gt;
&lt;li&gt;Next, search for &amp;lsquo;[CustomDBNames]&amp;rsquo;&lt;/li&gt;
&lt;li&gt;Under this section, Set &amp;lsquo;aiscsections_ml_SLS&amp;rsquo; against &amp;lsquo;AISCSections&amp;rsquo;&lt;/li&gt;
&lt;li&gt;&amp;nbsp;&lt;img alt=" " src="/resized-image/__size/640x480/__key/communityserver-wikis-components-files/00-00-00-00-54/1440.1.jpg" /&gt;&lt;/li&gt;
&lt;li&gt;Now, copy the &amp;lsquo;aiscsections_ml_SLS.db3&amp;rsquo; database to &amp;lsquo;C:\ProgramData\Bentley\Engineering\STAAD.Pro CONNECT Edition\Sections&amp;rsquo;&lt;/li&gt;
&lt;li&gt;There are a couple of more copies of the &amp;ldquo;Custom.ini&amp;rdquo; file within the following folders.&lt;/li&gt;
&lt;li&gt;C:\Program Files\Bentley\Engineering\STAAD.Pro CONNECT Edition\STAAD\Sections&lt;/li&gt;
&lt;li&gt;C:\ProgramData\Bentley\Engineering\STAAD.Pro CONNECT Edition\Sections&lt;/li&gt;
&lt;li&gt;In case you do not see the same entries updated in those files, please go ahead and manually change the data as suggested in steps 3 to 6 in these files too.&lt;/li&gt;
&lt;li&gt;StaadPro should now pick up sections from the above user database.&lt;/li&gt;
&lt;/ol&gt;
&lt;p&gt;&lt;/p&gt;
&lt;p&gt;.&lt;/p&gt;
&lt;p&gt;&lt;strong&gt;&lt;span style="font-size:200%;"&gt;Solution&lt;/span&gt;&lt;/strong&gt;&lt;/p&gt;
&lt;p&gt;The problem&amp;nbsp;will be addressed in the STAAD.Pro Connect Edition&amp;nbsp;Update&amp;nbsp;3 .&amp;nbsp;&lt;/p&gt;
&lt;p&gt;&lt;/p&gt;
&lt;p&gt;&lt;b&gt;&lt;img alt=" " height="60" src="/cfs-file.ashx/__key/communityserver-components-sitefiles/TSG-Logo.png" width="189" /&gt;&lt;/b&gt;&lt;/p&gt;&lt;div style="clear:both;"&gt;&lt;/div&gt;

&lt;div style="font-size: 90%;"&gt;Tags: custom section database, section database, known issue, db3, user section, Database, 21.00.02.30&lt;/div&gt;