Bentley Communities
Bentley Communities
  • Site
  • User
  • Site
  • Search
  • User
  • Welcome
  • Products
  • Support
  • About
  • More
  • Cancel
RAM | STAAD | ADINA
  • Product Communities
  • More
RAM | STAAD | ADINA
RAM | STAAD | ADINA Wiki RAM Connection CONNECT Edition Update 1 (v12.0.1) Release Notes
    • Sign in
    • Working Remotely with RAM or STAAD
    • -RAM | STAAD | ADINA Wiki
      • +Integrated Structural Modeling
      • +Limcon
      • +Microstran
      • +MStower
      • +RAM Concept
      • -RAM Connection
        • +Known Issues in Ram Connection
        • RAM Connection Key Features
        • -RAM Connection Release Notes
          • RAM Connection CONNECT Edition Update 1 (v12.0.1) Release Notes
          • RAM Connection CONNECT Edition (v12.0.0) Release Notes
          • RAM Connection CONNECT Edition v11.2.0.013 Release Notes
          • RAM Connection CONNECT Edition Update 1 (v11.1.0.227) Release Notes
          • RAM Connection CONNECT Edition v11.00.01.208 Release Notes
          • RAM Connection CONNECT Edition v11.0 Release Notes
          • RAM Connection 5.5.X Release Notes
          • RAM Connection V7.0 Release Notes
          • RAM Connection V7.3.1 Release Notes
          • RAM Connection V7.3.2 Release Notes
          • RAM Connection V8.0 Release Notes
          • RAM Connection V9.0 Release notes
          • RAM Connection V9.1 Release Notes
          • RAM Connection V9.2 Release Notes
          • RAM Connection CONNECT Edition (v13.0.0) Release Notes
          • RAM Connection CONNECT Edition Update 1 (v13.1.0) Release Notes
          • RAM Connection CONNECT Edition Update 2 (v13.2.0) Release Notes
          • RAM Connection CONNECT Edition Update 2 (v13.2.1) Release Notes
          • RAM Connection CONNECT Edition Update 3 (v13.3.0) Release Notes
          • RAM Connection CONNECT Edition v11.1.1.240 Release Notes
          • RAM Connection CONNECT Edition V13 Update 4 (v13.4.0) Release Notes
          • RAM Connection CONNECT Edition V13 Update 4 (v13.4.1) Release Notes
          • RAM Connection CONNECT Edition V13 Update 5 (v13.5.0) Release Notes
          • RAM Connection CONNECT Edition V13 Update 6 (v13.6.0) Release Notes
          • RAM Connection CONNECT Edition V13 Update 6 (v13.6.1) Release Notes
          • RAM Connection CONNECT Edition V13 Update 7 (v13.7.0) Release Notes
        • +RAM Connection Support Solutions
      • +RAM Elements
      • +RAM SBeam
      • +RAM Structural System
      • +Scenario Services
      • +STAAD Advanced Concrete Design (RCDC)
      • +STAAD RCDC FE
      • +STAAD Foundation Advanced
      • +STAAD.building
      • +STAAD.offshore
      • +STAAD.Pro
      • +Structural Analysis Support Solutions
      • +Structural Dashboard
      • +Structural WorkSuite
      • Structural Synchronizer Links
    • +Webinars
    • +RAM | STAAD Learning Resources

     
     Questions about this article, topic, or product? Click here. 

    RAM Connection CONNECT Edition Update 1 (v12.0.1) Release Notes

    RAM Connection CONNECT Edition Update 1 (v12.0.1) Release Notes – Updated August 2018

    Resolved Issues:

    • AISC 360 chevron connection was showing an “Internal error” message as there were some glitches during its optimization. This is fixed now.

    • EN 1993 base plate connection assignation was slow for some particular cases. Base plate templates have been changed to always use the “Consider Compatibility Option” to reduce the assignation time.

    • AISC moment end plate template had some invalid configurations when a haunch was included. Templates are now fixed and show just valid configuration options regardless of the existence of a haunch.

    • Consider friction between base plate and support was causing an “Object of a reference” error due to a wrong base plate analysis for a tension only case. This is fixed and the friction is considered correctly regardless the base plate analysis.

    • AISC directly bolted connection for braces was incorrectly considering tension in the tension and shear interaction for slip critical bolts. Now tension is never considered as bolts in this connection type act just in shear.

    • Horizontal bracing connections were crashing for seismic loads. This was fixed and now all horizontal bracing connections are designed properly regardless the load type.
    • CONNECT Edition
    • RAM Connection
    • Share
    • History
    • More
    • Cancel
    • Carlos Perez Created by Bentley Colleague Carlos Perez
    • When: Wed, Aug 1 2018 5:23 PM
    • Seth Guthrie Last revision by Bentley Colleague Seth Guthrie
    • When: Tue, Aug 7 2018 12:53 PM
    • Revisions: 5
    • Comments: 0
    Recommended
    Related
    Communities
    • Home
    • Getting Started
    • Community Central
    • Products
    • Support
    • Secure File Upload
    • Feedback
    Support and Services
    • Home
    • Product Support
    • Downloads
    • Subscription Services Portal
    Training and Learning
    • Home
    • About Bentley Institute
    • My Learning History
    • Reference Books
    Social Media
    •    LinkedIn
    •    Facebook
    •    Twitter
    •    YouTube
    •    RSS Feed
    •    Email

    © 2021 Bentley Systems, Incorporated  |  Contact Us  |  Privacy |  Terms of Use  |  Cookies