Bentley Communities
Bentley Communities
  • Site
  • User
  • Site
  • Search
  • User
RAM | STAAD | ADINA
  • Product Communities
RAM | STAAD | ADINA
RAM | STAAD | ADINA Wiki Unit Error in user table
    • Sign In
    • -RAM | STAAD | ADINA Wiki
      • +ADINA
      • +Integrated Structural Modeling
      • +Structural Analysis Support Solutions
      • +RAM Concept
      • +RAM Connection
      • +RAM Elements
      • +RAM SBeam
      • +RAM Structural System
      • -STAAD.Pro
        • +How is STAAD.Pro licensed
        • +Installation Requirements
        • Security
        • +Revision History
        • -STAAD.Pro Support Solutions
          • +STAAD.Pro Analysis Solutions
          • +STAAD.Pro Design Solutions
          • +STAAD.Pro General Solutions
          • +STAAD.Pro General [FAQ]
          • +STAAD.Pro Verification Documents
          • STAAD.Pro Safety Related Features
          • List of Programs included in different types of License for STAAD.Pro
          • +STAAD.Pro Known Issues CE V22 Update 6
          • -Known Issues in STAAD.Pro CONNECT Edition
            • A "Failed to save document" error reported while creating a new model
            • Black Force Diagrams, Small Fonts or Color Changes
            • Crash when defining beam offsets
            • Elastic section modulus is incorrectly calculated for I section with cover plates for design as per AISC ASD (9th Edition)
            • Error in design of single angles as per AISC 360-16
            • Error in LTB Check as per Canadian S16-14 Code
            • Error in reading user table General type sections with profile points
            • Error Unhandled Exception when trying to open the editor in STAAD.Pro Connect Edition
            • Error when trying to create analytical model from the physical model
            • Exception Message Reported when Starting STAAD.Pro CE
            • Existing custom steel section databases cannot be opened in the STAAD.Pro CONNECT Edition
            • Incorrect Bending Capacity reported for Single Angles designed as per Canadian Steel Design Code CSA S16-09 or CSA S16-14
            • Members/Surfaces cannot be copied unless corresponding nodes are selected
            • New material with custom properties cannot be added in the STAAD.Pro Physical Modeler
            • Report Setup Does Not Allow Filtering of Load Cases in STAAD.pro Update 9
            • Run Analysis option is greyed out
            • Software crashes observed in STAAD.Pro CONNECT Edition 22.02.00.26
            • STAAD.Pro Crashes after AISC 360-16 design when tapered and non tapered members are used in a single design parameter block
            • STAAD.Pro is considering incorrect Cw values in some situations leading to incorrect LTB capacity calculations when designing per AISC 360-16
            • The .std files are not showing up with the STAAD.Pro CE icon
            • The Latitude parameter(IBC 2012) is being incorrectly set to zero
            • The Parametric Models Fails to Generate Mesh
            • Truss members with member loads
            • Unit Error in user table
            • Unity ratio displayed for only one member when designed as per AISC 360-16
            • User ID missing from the Output Report
            • Value of Basic Wind Speed generated as per the ASCE code cannot be edited using the GUI
            • When trying to import an ISM repository into STAAD.Pro, the Run option is grayed out
          • +Known Issues in STAAD.Pro V8i
          • STAAD Product Releases in December 2018 and Associated Licensing Changes
          • +Procedure for Downloading STAAD.Pro CE
          • +STAAD.Pro Developing The Model [FAQ]
          • +STAAD.Pro Driver Downloads [FAQ]
          • +STAAD.Pro Import Export Solutions
          • +STAAD.Pro Import/Export [FAQ]
          • +STAAD.Pro Installation/Licensing Solutions
          • +STAAD.Pro Miscellaneous Solutions
          • +STAAD.Pro Miscellaneous [FAQ]
          • +STAAD.Pro Modeling Solutions
          • +STAAD.Pro OpenSTAAD [FAQ]
          • STAAD.Pro OpenSTAAD_Solutions
          • +STAAD.Pro Postprocessing FAQ's
          • +STAAD.Pro Postprocessing Solutions
          • +STAAD.Pro TechNotes [TN]
          • STAAD.Pro Crashing for DELL laptop when Browsing a File Location
        • +STAAD.Pro CONNECT Edition - Tips & Tricks
        • Links for Technical Videos available in Bentley Structural YouTube Channel
        • +Integrated RAM Connection Solutions
        • +Recordings from past STAAD webinars
        • +Steel AutoDrafter
      • +STAAD Foundation Advanced
      • +STAAD Advanced Concrete Design (RCDC)
      • +STAAD.building
      • +STAAD RCDC FE
      • +Scenario Services
      • +STAAD.offshore
      • +Limcon
      • +Microstran
      • +MStower
      • +Structural Dashboard
      • +Structural WorkSuite
    • +RAM | STAAD Learning Resources

     
     Questions about this article, topic, or product? Click here. 

    Unit Error in user table

      Product: STAAD.pro
    First Affected Version: 21.03.00.146
      Found in Version: 21.03.00.146
    Fixed and Released in Version: 22.00.00.15
      Area:  Graphic User Interface
      Issue #: 956313

    Problem Description

    User table sections when defined using the graphic user interface are getting written in the input command file with a UNIT command within the user table definition block as shown next 

    ...

    START USER TABLE

    TABLE 1

    UNIT INCHES KIP

    GENERAL

    TEST1

    1112.25 80 0 47 0 995062 89512 27715.6 23232.6 3809.02 525.421 550.813 -

    30641.9 7257.83 8.04422e+07 80

    END 

    Subsequently the software is incorrectly reading all the properties in meter units. This is resulting in incorrect properties being considered for the analysis and design and also incorrect display of the structure in 3D.

    Workaround

    Open the STAAD.Pro command file in the editor and move the UNIT INCHES KIP command in the user table definition so that it comes just before the START USER TABLE line, as shown below

    ...

    UNIT INCHES KIP

    START USER TABLE

    TABLE 1

    GENERAL

    TEST1

    1112.25 80 0 47 0 995062 89512 27715.6 23232.6 3809.02 525.421 550.813 -

    30641.9 7257.83 8.04422e+07 80

    END 

    Once the data is Saved from within the editor, the file should work without any problem.

    Solution

    The problem has been addressed in the STAAD.Pro Connect Edition version 22.00.00.15. 

    • CONNECT Edition
    • user table
    • unit
    • known issue
    • 21.03.00.146
    • Share
    • History
    • More
    • Cancel
    • Sye Created by Bentley Colleague Sye
    • When: Mon, Nov 19 2018 4:10 PM
    • Sye Last revision by Bentley Colleague Sye
    • When: Tue, Sep 24 2019 6:52 PM
    • Revisions: 3
    • Comments: 0
    Recommended
    Related
    Communities
    • Home
    • Getting Started
    • Community Central
    • Products
    • Support
    • Secure File Upload
    • Feedback
    Support and Services
    • Home
    • Product Support
    • Downloads
    • Subscription Services Portal
    Training and Learning
    • Home
    • About Bentley Institute
    • My Learning History
    • Reference Books
    Social Media
    •    LinkedIn
    •    Facebook
    •    Twitter
    •    YouTube
    •    RSS Feed
    •    Email

    © 2023 Bentley Systems, Incorporated  |  Contact Us  |  Privacy |  Terms of Use  |  Cookies