Bentley Communities
Bentley Communities
  • Site
  • User
  • Site
  • Search
  • User
RAM | STAAD | ADINA
  • Product Communities
RAM | STAAD | ADINA
RAM | STAAD | ADINA Wiki RAM Connection CONNECT Edition V13 Update 6 (v13.6.1) Release Notes
    • Sign In
    • -RAM | STAAD | ADINA Wiki
      • +ADINA
      • +iTwin Analytical Synchronizer_
      • +Structural Analysis Support Solutions
      • +RAM Concept
      • -RAM Connection
        • +RAM Connection Feature Articles
        • +RAM Connection Key Features
        • -RAM Connection Release Notes
          • RAM Connection 2023 (v23.0.1) Release Notes
          • RAM Connection 2023 (v23.0.0) Release Notes
          • RAM Connection CONNECT Edition V13 Update 9 (v13.9.0) Release Notes
          • RAM Connection CONNECT Edition V13 Update 8 (v13.8.0) Release Notes
          • RAM Connection CONNECT Edition V13 Update 7 (v13.7.1) Release Notes
          • RAM Connection CONNECT Edition V13 Update 7 (v13.7.0) Release Notes
          • RAM Connection CONNECT Edition V13 Update 6 (v13.6.1) Release Notes
          • RAM Connection CONNECT Edition V13 Update 6 (v13.6.0) Release Notes
          • RAM Connection CONNECT Edition V13 Update 5 (v13.5.0) Release Notes
          • RAM Connection CONNECT Edition V13 Update 4 (v13.4.1) Release Notes
          • RAM Connection CONNECT Edition V13 Update 4 (v13.4.0) Release Notes
          • RAM Connection CONNECT Edition Update 3 (v13.3.0) Release Notes
          • RAM Connection CONNECT Edition Update 2 (v13.2.1) Release Notes
          • RAM Connection CONNECT Edition Update 2 (v13.2.0) Release Notes
          • RAM Connection CONNECT Edition Update 1 (v13.1.0) Release Notes
          • RAM Connection CONNECT Edition (v13.0.0) Release Notes
          • RAM Connection CONNECT Edition Update 1 (v12.0.1) Release Notes
          • RAM Connection CONNECT Edition (v12.0.0) Release Notes
          • RAM Connection CONNECT Edition v11.2.0.013 Release Notes
          • RAM Connection CONNECT Edition v11.1.1.240 Release Notes
          • RAM Connection CONNECT Edition Update 1 (v11.1.0.227) Release Notes
          • RAM Connection CONNECT Edition v11.00.01.208 Release Notes
          • RAM Connection CONNECT Edition v11.0 Release Notes
          • RAM Connection V9.2 Release Notes
          • RAM Connection V9.1 Release Notes
          • RAM Connection V9.0 Release notes
          • RAM Connection V8.0 Release Notes
          • RAM Connection V7.3.2 Release Notes
          • RAM Connection V7.3.1 Release Notes
          • RAM Connection V7.0 Release Notes
          • RAM Connection 5.5.X Release Notes
        • +RAM Connection Support Solutions
        • +Known Issues in Ram Connection
      • +RAM Elements
      • +RAM SBeam
      • +RAM Structural System
      • +STAAD.Pro
      • +STAAD Foundation Advanced
      • +STAAD Advanced Concrete Design (RCDC)
      • +STAAD.building
      • +STAAD RCDC FE
      • +Scenario Services
      • +STAAD.offshore
      • +Limcon
      • +Microstran
      • +MStower
      • +Structural Dashboard
      • +Structural WorkSuite
    • +RAM | STAAD Learning Resources
    • Simplifications to Bentley's Engineering Simulation Software Licenses

    You are currently reviewing an older revision of this page.

    • History View current version

    RAM Connection CONNECT Edition V13 Update 6 (v13.6.1) Release Notes

    RAM Connection CONNECT Edition V13 Update 6 Patch 1 (v13.6.1) Release Notes – Updated December 2021

    This is a patch release (full installer) for RAM Connection v13.6.0 release.

    Resolved Issues:

    • AISC Chevron connection in RAM Connection stand alone was not transferring correctly forces from the joint to the connection. 

    • AISC Truss-Gusset-Branch connection had a glitch when calculating bolted net area as bolt rows and columns where inverted.
    • AISC Column-Beam-Brace gusset had a nullable object error caused  by the Is column end property used in the calculation of the web plate strength due out-of-plane transverse load.

    • RAM Connection for RAM Structural System had some issues detecting BCF joints as some joints were being detected as CVR joints. This is fixed now and all joints included CVR and Chord-Branch joints are detected properly.

    • EN Column-Beam-Brace gusset brace bolt bearing check wrong thickness for I2C and T2L braces as thickness needs to be duplicated.

    • AS Flange Cover Plate net area not considering number of bolt columns properly for C sections.
    Communities
    • Home
    • Getting Started
    • Community Central
    • Products
    • Support
    • Secure File Upload
    • Feedback
    Support and Services
    • Home
    • Product Support
    • Downloads
    • Subscription Services Portal
    Training and Learning
    • Home
    • About Bentley Institute
    • My Learning History
    • Reference Books
    Social Media
    •    LinkedIn
    •    Facebook
    •    Twitter
    •    YouTube
    •    RSS Feed
    •    Email

    © 2023 Bentley Systems, Incorporated  |  Contact Us  |  Privacy |  Terms of Use  |  Cookies