Pl refer to Annexure A off IS 13920 which states walls are to be designed for uniaxial bending. Columns are considered as biaxial. Hence, their design cannot be clubbed under one set
Annex A of IS 13920 is about the calculation of moment of resistance of the web portion of rectangular wall section. This is further used only in calculation of effective axial force in boundary element due to major axis moment. It may please also be noted in IS 456 which is the main code for design there is no separate procedure for design of walls. Clause no 39.6 of IS 456 refers to members subjected combined axial and biaxial bending which includes column and walls. Thus for biaxial design RCDC follows the basic principle of plotting P-M curve for design and checks for boundary element using annex-A provided in IS 13920. For more information refer Topic “Technical discussion” for column from help Content.