Problem: When CAN 1 parameter is used to perform Deflection Check results are not reported correctly. Solution:
For such cases, section property is incorrectly accessed from the memory while checking for deflection hence an incorrect deflection is reported for such members. Its' reported only in AISC-16. Break up the CHECK CODE member list command and ensure every member lists becomes LESS than 1000. For example, if CHECK CODE is specified for more than 1000 continuous members, bring it down to two / multiple lines as Check Code Member 1 to 999 (say) Check Code Member 1000 +. However, this issue was addressed and will be fixed in one of the future releases.