Bentley Communities
Bentley Communities
  • Site
  • User
  • Site
  • Search
  • User
RAM | STAAD | ADINA
  • Product Communities
RAM | STAAD | ADINA
RAM | STAAD | ADINA Wiki Customization of anchors in base plate for Euro Code in RAM Connection
    • Sign In
    • -RAM | STAAD | ADINA Wiki
      • +ADINA
      • +iTwin Analytical Synchronizer_
      • +Structural Analysis Support Solutions
      • +RAM Concept
      • -RAM Connection
        • +RAM Connection Feature Articles
        • +RAM Connection Key Features
        • +RAM Connection Release Notes
        • -RAM Connection Support Solutions
          • +RAM Connection Capabilities and Modeling FAQ
          • RAM Connection Single Plate Connections [FAQ]
          • +RAM Connection Base Plate FAQ
          • RAM Connection Gusset Connections FAQ
          • Base Plate Connection,Tension & shear reinforcement
          • CBB looks rotated when sent to RAM Connection
          • Creating Custom Connection Templates
          • Customization of anchors in base plate for Euro Code in RAM Connection
          • Customized location of baseplate on Foundation
          • Directly welded round pipe truss connection in RAM Connection
          • Error while rendering the report in RAM Connection
          • Exists Opposite Connection
          • Help file for RAM Connection in pdf format
          • How Lev,top and lev,bottom are calculated for a CBB connection
          • +How to model eccentric column base plate in RAM Connection?
          • Icons in the side panel are distorted
          • In Beam Column Flange design with CSA S16-14 code, some checking is referred to AISC code
          • In the case of many joints in structure can we select just one critical joint to design that covers every joints.
          • +Installation - RAM Connection
          • Is there any option of introducing Column Flange Doubler in AISC code as in CSA code?
          • RAM Connection Extended End-Plate Moment Connections (MEP)
          • Ram Connection for Ram SS Load Combinations
          • Tension T-Stub cannot be calculated with the current fastener positions
          • Troubleshooting Errors when Assigning Connections
          • Usage counts more than threshold limit even when offline usage was disabled
          • Web fillet weld axial capacity check when load is zero as per Australian code
          • Web Plate strength due out-of-plane transverse load
          • How the demands in the Column Cap connection are calculated?
        • +Known Issues in Ram Connection
      • +RAM Elements
      • +RAM SBeam
      • +RAM Structural System
      • +STAAD.Pro
      • +STAAD Advanced Concrete Design (RCDC)
      • +STAAD Foundation Advanced (SFA)
      • +STAAD.building
      • +STAAD RCDC FE
      • +Scenario Services
      • +STAAD.offshore
      • +Limcon
      • +Microstran
      • +MStower
      • +Structural Dashboard
      • +Structural WorkSuite
    • +RAM | STAAD Learning Resources
    • Simplifications to Bentley's Engineering Simulation Software Licenses

     
     Questions about this article, topic, or product? Click here. 

    Customization of anchors in base plate for Euro Code in RAM Connection

    Applies To
    Product(s): RAM Connection
    Version(s): Connect Edition
    Environment:
    Area: RAM Connection
    Subarea: Connection design
    Original Author: Abhisek Mandal, Bentley Technical Support Group

     

    In RAM Connection how to model base plate with anchors in customized numbers and positions for Euro Code?

    In RAM Connection base plate for Euro code there are 2 set of templates.

    We need to choose Base Plate Biaxial EN option and then choose any one of them. But choosing the fixed biaxial BP EN is recommended as it provides the direct option to input values. Else, we can change the analysis type to Biaxial in the connection pad as shown below.

    Once we choose these templates, new fields will be available under anchor tab to provide input for anchor positions and numbers. These values will actually guide the position of anchors in the base plate. 

    • baseplate
    • RAM Conection
    • customize anchor numbers
    • anchor position
    • EN code
    • Share
    • History
    • More
    • Cancel
    • Abhisek M Created by Bentley Colleague Abhisek M
    • When: Wed, Aug 17 2022 8:57 AM
    • Sabrina Tedeschi Last revision by Bentley Colleague Sabrina Tedeschi
    • When: Wed, May 3 2023 8:18 AM
    • Revisions: 2
    • Comments: 0
    Recommended
    Related
    Communities
    • Home
    • Getting Started
    • Community Central
    • Products
    • Support
    • Secure File Upload
    • Feedback
    Support and Services
    • Home
    • Product Support
    • Downloads
    • Subscription Services Portal