Bentley Communities
Bentley Communities
  • Site
  • User
  • Site
  • Search
  • User
RAM | STAAD | ADINA
  • Product Communities
RAM | STAAD | ADINA
RAM | STAAD | ADINA Wiki Warning - The value of Fyld for member (cable) does not seem to be right
    • Sign In
    • -RAM | STAAD | ADINA Wiki
      • +ADINA
      • +iTwin Analytical Synchronizer_
      • +Structural Analysis Support Solutions
      • +RAM Concept
      • +RAM Connection
      • +RAM Elements
      • +RAM SBeam
      • +RAM Structural System
      • -STAAD.Pro
        • +(+) Revision History
        • -(+) STAAD.Pro Support Solutions
          • STAAD.Pro Safety Related Features
          • +STAAD.Pro Postprocessing Solutions
          • -(+) Analytical Modeling workflow
            • +STAAD.Pro Analysis Solutions
            • -STAAD.Pro Design Solutions
              • +STAAD.Pro Aluminum Design
              • +STAAD.Pro Concrete Design
              • +STAAD.Pro General Design Solutions
              • -STAAD.Pro Steel Design
                • +(+) Verification Problems for Steel Design Codes
                • +American Steel Design Codes AISC
                • +API 2A-WSD 21st Edition
                • +British Steel Design code BS 5950-1:2000
                • +Canadian Steel Code S16
                • +European Steel Design code EN 1993-1-1:2005 (EC3)
                • +General Steel Design Solutions
                • -Indian Steel Design codes IS 800
                  • Addendum-1 to IS:800-2007
                  • Compression Capacity Check of Laterally Unsupported ISMB Section
                  • Deflection Check of Laterally Unsupported ISMB Section
                  • Design of User defined section according to IS800:2007 code
                  • Interaction Check of Laterally Unsupported ISMB Section
                  • Major Axis Bending Capacity of a Web Slender I Section
                  • Moment Capacity Check of Laterally Unsupported ISMB Section
                  • Question: I have modelled a simple symmetric structure with channel sections and applied symmetric vertical loading to it. I have used IS800-2007 as design code. The columns doesn't show symmetry in UC ratio. Please help.
                  • +Section Classification of Laterally unsupported ISMB section
                  • Serviceability Check in Design According to IS800:2007
                  • Shear Capacity Check of Laterally Unsupported ISMB Section
                  • Slenderness Check of Laterally Unsupported ISMB Section
                  • STAAD.Pro IS800 2007 Verification Examples
                  • STP Parameter per IS:800-2007
                  • Tension Capacity Check of Laterally Unsupported ISMB Section
                  • Warning - The value of Fyld for member (cable) does not seem to be right
                  • Warnings in IS800:2007
              • +STAAD.Pro Timber Design
              • +Warnings and Errors related to IS13920 2016 concrete design in STAAD.Pro
            • +STAAD.Pro General Solutions
            • +STAAD.Pro Import/Export Solutions
            • +STAAD.Pro Modeling Solutions
            • +STAAD.Pro OpenSTAAD
          • +(+) Building Planner workflow
          • +(+) Connection Design workflow
          • +(+) Physical Modeling workflow
          • +(+) Piping workflow
          • +(+) Postprocessing workflow
          • +(+) Steel AutoDrafter worfklow
        • +(+) Archived Wikis
        • +(+) STAAD.Pro Download/Installation/Security/Performance
        • +(+) STAAD.Pro Known Issues
        • +(+) STAAD.Pro Licensing Solutions
        • +(+) STAAD.Pro Webinars/Videos/Events
      • +STAAD Foundation Advanced
      • +STAAD Advanced Concrete Design (RCDC)
      • +STAAD.building
      • +STAAD RCDC FE
      • +Scenario Services
      • +STAAD.offshore
      • +Limcon
      • +Microstran
      • +MStower
      • +Structural Dashboard
      • +Structural WorkSuite
    • +RAM | STAAD Learning Resources
    • Simplifications to Bentley's Engineering Simulation Software Licenses

     
     Questions about this article, topic, or product? Click here. 

    Warning - The value of Fyld for member (cable) does not seem to be right

       
      Applies To 
       
      Product(s): STAAD.Pro
      Version(s): All
      Environment:  N/A
      Area:  IS 800:2007 Code
      Subarea:  N/A
      Original Author: Ranjana, Bentley Technical Support Group
       

    Question:

    While analyzing the network tied arch bridge in Staad Pro the following warning appears ‘The value of Fyld for member (cable) does not seem to be right’. The Actual value is 1240N/sqmm (1240000kN/sqm). Please find the attached model for your reference. Kindly help to eliminate this error.

    Answer:

    You have used IS800 code which is used to design the structural steels. Generally, the maximum yield stress in those structural steels are in the range to 500 to 600 N/mm2. Here you have used 1240 N/mm2 which is much higher than that and hence program is throwing such warning to double check if the input is correct or not. If you want to use that value, please go ahead as the program is taking that value in the calculation and you can use TRACK 2 parameter to check that in detailed output.

    If you want to suppress these warnings, you can use "SET NOWARNING" command in your model. Please make sure that there are no other warnings in the file as this command will suppress most of the warnings.

    • fyld warning is800
    • STAAD.Pro
    • etc
    • IS800
    • Share
    • History
    • More
    • Cancel
    • Ranjana Shinde Created by Bentley Colleague Ranjana Shinde
    • When: Mon, Dec 19 2022 7:59 AM
    • Abhisek M Last revision by Bentley Colleague Abhisek M
    • When: Mon, Dec 19 2022 8:08 AM
    • Revisions: 3
    • Comments: 0
    Recommended
    Related
    Communities
    • Home
    • Getting Started
    • Community Central
    • Products
    • Support
    • Secure File Upload
    • Feedback
    Support and Services
    • Home
    • Product Support
    • Downloads
    • Subscription Services Portal
    Training and Learning
    • Home
    • About Bentley Institute
    • My Learning History
    • Reference Books
    Social Media
    •    LinkedIn
    •    Facebook
    •    Twitter
    •    YouTube
    •    RSS Feed
    •    Email

    © 2023 Bentley Systems, Incorporated  |  Contact Us  |  Privacy |  Terms of Use  |  Cookies