Critical and High Issues Identified in STAAD.Pro
STAAD.Pro 22.00.00.15
STAAD.Pro 22.01.00.39
STAAD.Pro 22.02.00.26
STAAD.Pro 22.03.00.28
STAAD.Pro 22.04.00.40
STAAD.Pro 22.05.00.131
STAAD.Pro 22.06.00.138
STAAD.Pro 22.07.00.160
STAAD.Pro 22.08.00.175
STAAD.Pro 22.09.00.115
STAAD.Pro 22.10.00.153
STAAD.Pro 22.11.00.156
STAAD.Pro 22.12.00.142
STAAD.Pro 23.00.00.345/23.00.01.25
+
Known Issues in STAAD.Pro CONNECT Edition
+
Known Issues in STAAD.Pro V8i
+
STAAD.Pro Download/Installation/Performance/Security
+
STAAD.Pro Licensing Solutions
+
STAAD.Pro Webinars/Videos/Events
+
STAAD Advanced Concrete Design (RCDC)
+
STAAD Foundation Advanced (SFA)
+
STAAD.building
+
STAAD RCDC FE
+
Scenario Services
+
STAAD.offshore
+
Limcon
+
Microstran
+
MStower
+
Structural Dashboard
+
Structural WorkSuite
+
RAM | STAAD | ADINA Learning Resources
Simplifications to Bentley's Engineering Simulation Software Licenses
Questions about this article, topic, or product? Click here.
STAAD.Pro 22.08.00.175
List of critical and high severity defects identified in STAAD.Pro V22 build 22.08.00.175.
Issue ID
Title
Severity
1st affected Build
Fixed in Build
A-487670
Incorrect base shear being generated as per Equivalent Lateral Force Method using IBC 2018
2 - High
22.02.00.26
22.10.00.153
A-524650
Member section displacement results do not account for lateral releases on members
2 - High
20.07.04.12
Known Issue
A-698135
SANS 10162-1 : UNT and UNB parameters
2 - High
20.07.11.33
22.09.00.115
A-772936
1893 2015-P4 : Response Spectrum load case in Y direction
2 - High
22.08.00.175
22.10.00.153
A-774908
AISC 360-16: Effect of eccentricity for single angle profiles
2 - High
22.02.00.26
22.09.00.115
A-784278
AISC N690 1984: Shear design for pipe sections
2 - High
20.07.06.23
22.09.00.115
A-813848
Unbraced length : UNF and UNL Parameters
2 - High
20.07.08.32
22.10.00.153
A-817499
EN 1993-1-1:2005 : LEG parameter for single angle profiles
2 - High
20.07.07.32
22.11.00.156
A-852094
AISC 360-16 : FY and FU not considered from assigned material
2 - High
21.00.02.44
22.10.00.180
A-852547
AS 4100 1998 : MAIN and TMAIN Parameters
2 - High
22.06.00.138
22.11.00.156
A-865805
Incorrect ELFP Torsional Moment : Optional Load Factor Multiplication
2 - High
22.01.00.39
22.10.00.180
A-865842
AISC 341-16 : Incorrect Seismic Classification for Custom Steel
2 - High
22.01.00.39
22.10.00.180
A-907678
Direct Analysis : Default Steel Yield Strength
2 - High
22.07.00.160
22.12.00.142
A-935629
AISC 360-16: SGR parameter
2 - High
21.00.02.44
22.12.00.142
A-969825
AISC 360-10/05 : Combined flexure and tension
2 - High
20.07.11.50
22.12.00.142
A-973697
AS4100-1998 : Moment modification factor
2 - High
20.07.11.90
23.00.00.345
A-1003677
NZS-3404-1997 : Physical member design
2 - High
21.00.00.57
23.00.00.345
A-1005695
NZS-3404-1997 : Analytical Member Design
2 - High
21.00.00.57
23.00.00.345
A-1015058
AISI 2016 : Deflection checks
2 - High
22.04.00.40
23.00.00.345
A-993314
CSA S16-09/14/19: Incorrect calculation of Shear Buckling resistance for Pipe members
2 - High
22.08.00.175
23.00.00.345
A-1032348
AISC 360-16 and BS5950 Pt 1 : Incorrect shear capacity parallel to the flanges for Double Channel profiles
2 - High
21.00.02.30
23.00.00.345
A-999611
Incorrect Time History analysis results with a Harmonic Ground motion
2 - High
20.07.04.12
22.12.00.142
A-1037816
CSA S16-09/14/19 ignores user provided shear areas for UPT ISECTION and UPT WIDE FLANGE profiles
1 - Critical
22.08.00.175
23.00.00.345
A-996557
IS800:1984: Properties determined by incorrect CG position
2 - High
22.05.00.131
23.00.00.345
A-1073141
IBC 2012/2015/2018: Failure to process negative accidental eccentricity factor in Response Spectrum Analysis
1 - Critical
20.07.11.33
23.00.00.345
A-1121536
EN 1993-1-1:2005 : Failure to perform Bending Check (Clause 6.2.5) and Buckling Check (Equations 6.3.3-661, 662)
1 - Critical
20.07.11.90
23.00.00.345
A-1176400
AISC 360-05/10: Slenderness of Single Angle
2 - High
20.07.11.50
Known Issue
A-1199138
AISC 360-16: Incorrect H2-1 at the Heel of an Equal Angle
2 - High
21.00.02.44
23.00.00.345
A-1213593
CSA S16-09/14/19 : Failure to account for effective length factors when calculating compressive resistance Cr
2 - High
22.08.00.175
Known Issue
A-1221514
Wind Load Panel Formation affected by support nodes
2 - High
20.07.04.12
Known Issue
A-1225794
AS4100-1998 & NZS 3404 -1997: Reference buckling moment for wide flange profiles with unequal flanges
2 - High
20.07.11.90
Known Issue
A-1232633
CSA S16-09/14/19: Incorrect Evaluation of Factored Moment Resistance
1 - Critical
20.07.10.64
Known Issue
A-1238499
IS456-2000 : Check for maximum stirrup spacing as per Cl 26.5.1.5
2 - High
22.07.00.160
Known Issue
A-1247472
AS4100-1998 : Member moment capacity checks as per Clauses 8.4.2.2 and 8.4.4.1
2 - High
20.07.11.90
Known Issue
A-1271381
AS4100-1998 : Physical member design
2 - High
20.07.09.31
Known Issue
Share
History
More
Cancel
Created by
Carlos Aguera
When:
Mon, Feb 20 2023 11:24 AM
Last revision by
Debajit Das
When:
Fri, Oct 20 2023 3:56 AM
Revisions:
18
Comments:
0